• 제목/요약/키워드: inside clothing humidity

검색결과 41건 처리시간 0.023초

통기성 향상을 위한 하계비행복 설계 및 착용쾌적성 평가 (Wearing Comfort Evaluation of a Summer Flight Suit to Improve Ventilation)

  • 전은진;박세권;유희천;김희은
    • 한국의류산업학회지
    • /
    • 제16권3호
    • /
    • pp.485-491
    • /
    • 2014
  • This study verified the effect of summer flight ventilation developed in a previous study based on wearing comfort evaluation. Seven healthy males in their twenties volunteered for this experiment conducted in aclimatic chamber. The experiment consisted of three consecutive periods of rest (20 minutes), running on a treadmill (10 minutes) and recovery (20 minutes). A comparative evaluation was conducted on the general flight suit which had no ventilation holes and summer flight suit that use subjective satisfaction measures and objective measures. The subjective satisfaction was evaluated according to the criteria of temperature sensation, wet sensation, thermal comfort and fatigue sensation. The objective satisfaction was measured by skin temperature, microclimate (temperature and humidity), sweat rate and thermography. The comparative wearing evaluation identified the summer flight suit decreased the temperature between skin and suit by $0.42^{\circ}C$ (upper arm), $0.9^{\circ}C$ (calf) and the skin temperature by $0.3^{\circ}C$ (shoulder), $0.4^{\circ}C$ (upper arm), $0.5^{\circ}C$ (calf) as compared to the general flight suit. The humidity inside the summer flight suit decreased at head (7.73%), shoulder (5.86%), upper arm (5.26%), and calf (8.73%) compared to the one inside the general flight suit. Thermography showed that the air flowed through ventilation holes (neck and armpit). The design of ventilation holes applied to the summer flight suit can be applicable to overall clothing that requires thermal comfort such as dust-free garments, mechanical clothing and combat uniforms.

편성물의 기모가공이 착용감에 미치는 영향 (The Effect of Napping of Knitted Fabric on Wear Sensation)

  • 이종민;이순원
    • 한국의류학회지
    • /
    • 제11권3호
    • /
    • pp.41-55
    • /
    • 1987
  • The purpose of this study is to investigate the effects of napping of knitted fabric on wear sensation and physiological responses. Experimental garments were four types of warm-ups made of either $100\%$ PET or $65/35\%$ P /C and either napped or unnapped respectively. Two healthy young female adults were chosen as subjects for the experiment. Experimental room conditions were as follows: Temp., $22\pm0.5^{\circ}C$ R.H., $54\pm3\%$ and Air Velocity, 0.25m/ sec or 2. 86m/sec. The subjects exercised on bicycle ergometer and rested alternatively for totally 45-min. The results are summarized as follows. 1) With napped Warm-up, chest, back, mean skin temp. and microclimates, i.e., temp., relative humidity and water vapor pressure inside the clothing, were higher than with unnapped warm-up. And there was no difference in pulse rate between napped and unnapped warm-ups. 2) Wear sensations of thermal, humidity, tactile and comfort were 'more hot' and 'more uncomfortable' in 0.25m/sec air velocity. but in 2.86m/sec condition the tactile sensation was 'better' and 'more comfortable' with napped warm-ups. According to Pearson's Correlation, among various kinds of wear sensations, tactile is most related with comfort. From these results, it can be concluded that napped fabric decreases the rate of heat trans? mission and moisture diffusion through the clothing. Therefore skin and body temp. and temp., R.H., Vapor Pressure inside the clothing are increased.

  • PDF

여름철 셀룰로오스 섬유 의복의 착용감에 관한 연구 (A Study on the Wear Sensation Cellulose Fabric in Summer)

  • 권수애;이순원
    • 한국의류학회지
    • /
    • 제12권1호
    • /
    • pp.81-91
    • /
    • 1988
  • The purpose of this study is to investigate the physiolosical responses and subjective wear sensation to the clothes with different cellulose composition. The experimental garments were four types of cellulosic fabrics, respectively composed of $100\%$-cotton, $100\%$-Rayon, cotton/Flax 85/15, and rayon/Flax 85/15 (weft blended), were sewn in blouses with half-length sleeves. Four healthy women were chosen for this experiment. The condition of the experimental room were in two environments: Temp., $25{\pm}1^{\circ}C$, R.H. $60{\pm}3\%$ and Temp., $30{\pm}1^{\circ}C$, R.H. $70{\pm}3\%$, and air velocity was maintained at 0.25 m/sec. The results are as follows. 1) At $25^{\circ}C$, rayon blouse showed the pleasantest feeling because of its excellent humidity sensation and tactile sensation. At $30^{\circ}C$, rayon and flax blended blouse showed most comportable sensation. In both environments, blouse of $100\%$ cotton showed the least pleasant because of high vapor pressure inside the blouse and bad tactile sensation. 2) Vapor pressure inside the blouse and tactile sensation play the most impotant role in comfort. Consequantly the blouse made of $100\%$-cotton which bring low air permeability, moisture regain and water vapor permearbility showed more unpleastness than rayon blouse because it raises temperature, relative humidity and vapor pressure inside the blouse under the hot circumstances In the conditions with much sweat, rayon and flax blended blouse with high stiffness increases comfort better than $100\%$ rayon because the former prevents sticking to the skin.

  • PDF

온돌환경이 수면시의 생리반응에 미치는 영향(제1보) -가을, 겨울철 수면시 침실내 온열환경과 침상기후- (Effect of Ondol on physiological Responses during Sleep (I) -On the focus of Bedclimate in Autumn and Winter-)

  • 이순원;권수애;최정화
    • 한국의류학회지
    • /
    • 제20권4호
    • /
    • pp.697-706
    • /
    • 1996
  • The actual conditions of bed climate are investigated depending on the regions and housing styles used on ondol in autumn and winter. Sixty healthy men and women (30 of them live in apartmrnt and 30 of them live in detached house, 20 of them live in Wonju, 20 of them live in Wonju, 20 of them live in Cheongju and 20 of them live in Pusan) The results are as follows: 1) No significant differences was shown between the seasons of bedclothes thickness. 2) In the autumn, the temperature and humidity of bedroom, on the mattress, inside the bedquilt, and inside the sleep-wear were higher than those in the winter. The temperature of ondol floor and under the mattress in winter were higher than those in the autumn. 3) The differences of the temperature and humidity of bedroom, the bed climate, and the clothing microclimate were significant by the regions and housing styles in both seasons. In both seasons, the temperature of bedroom, on the mattress, inside sleep-wear in the apartment were higher than those in the detached house. 4) The differences of subjective sensation on the bedroom conditions were not significant by the sextons, the regions, and the housing styles. Most subjects perceived that the conditions of bedroom were somehow hot and dry, but comfortable.

  • PDF

더운 환경에서 산업용 각반 착용 시 인체생리반응 (Physiological Responses of Wearing Industrial Gaiters in a Hot Environment)

  • 최정화;박준회
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

Development and Evaluation of Protective Clothing for Rose Farmers

  • Chae, Hyeseon;Kim, Sungchul;Oh, Youngsoon;Lee, Kyungsook;Kim, Hyocher;Park, Soonjee
    • 한국의류학회지
    • /
    • 제40권3호
    • /
    • pp.427-436
    • /
    • 2016
  • Protective clothing developed for rose flower farmers has been evaluated to improve the working conditions. The requirements of rose farmers were first identified to design protective clothing for farmers working with thorny plants. A fit test was conducted to assess the thermal comfort and protective function against thorn pricking to compare and evaluate the usability of developed experimental clothing with existing working clothes. Based on the survey results of rose farmers' requirements, protective clothing was designed in the form of an apron (which was the most preferred after gloves) with a pattern designed for the production of experimental clothing. For the developed protective clothing, the strap and buckle closure method was selected to open the back of the body as much as possible; in addition, sleeves were made in the attachable form of a half-sleeve to protect the arms from the thorns. The fit test of the developed protective clothing and existing working clothes revealed the temperature and humidity inside the developed protective clothing to be significantly different in the back compared to existing work clothes. In addition to thermal sensations, the subjective humidity sensations were statistically significant different in the developed protective clothing compared to existing work clothes. The subjective protective function for thorn pricking was also found to be satisfactory.

노인여성의 착의량과 건강관련변인 (A Study on Clothing Weight and Cornell Medical Index in Elderly Women)

  • 김양원
    • 한국생활과학회지
    • /
    • 제18권5호
    • /
    • pp.1087-1092
    • /
    • 2009
  • From the environmental adaptation point of view, the clothing habits made by the thermal sensation and clothing weight of elderly women have changed according to the thermal sensation and health condition. The purpose of this study was to obtain the basic data for developing healthy and comfortable clothing for elderly women. Clothing weight, thermal sensation, clothing microclimate, resistance to cold and heat of 198 elderly women in Taejeon were surveyed from October 9, 2007 to October 19, 2007. 1. Clothing weight per body surface area was $830.4g/m^2$ of total clothing weight, $242.8g/m^2$ of underwear clothing weight, $617.3g/m^2$ of outerwear clothing weight, $419.8g/m^2$ of upper clothing weight, and $420.4g/m^2$ of lower clothing weight. 2. More than 90% of the respondents replied that they felt comfortable when the temperature inside the clothing was $33.5^{\circ}C$ and humidity inside the clothing was 30.2%. 3. The elderly women were more sensible to cold than to hot, those who felt cold had a tendency to wear heavier clothing. 4. The appeal rate for physical pain of older and lower income people, especially those with an income under 1,000,000 won, was higher than that of others. On the other hand, the lower the subjective economic level, the younger they were, and the more the monthly average income was, the higher the rate of mental pain. 5. The heavier the total clothing weight was, the higher the appeal rate for general pain.

지뢰 탐지용 방호복 구성과 방호성능 및 착용감 평가 (A Study on The Development and Evaluation of Mine Detective Gear)

  • 손부현;최혜선
    • 한국의류학회지
    • /
    • 제25권4호
    • /
    • pp.707-718
    • /
    • 2001
  • The purpose of this study is to evaluate a newly developed protective suit with the fragments of grenade. The protection efficiency should be strengthened upon the degree of wound. The fragment weight of the used grenade was measured and the kinetic energy of the maximum speed of the fragments in the field test was 137.7J and this could be the protective efficiency test by the multitude fragments in less than 0.031g of the M16A1. The panel inserted to the new demining suit has protection rate of 100% within the distance of 1m and sample II has protection rate of 100% only beyond the distance of 5m. The test showed that the protection rate on the protective suit of the existing garment was comparatively high, however, the protection rate of the sleeve part was very low. The new demining suit through the research demand some complementary measures to lower the temperatures in ear, average skin temperatures, and the temperatures-humidity inside the clothing for summer climate condition, It showed that 30 minutes of rest on the clothing was difficult to go back to the original condition. But in winter climate condition, there was no problem in the temperature, humidity, and comfort to go back to the original condition during the rest and was better in warmth.

  • PDF

피부온에 영향을 미치는 인자에 관한 연구 (A Study of Factors Influencing on Skin Temperature)

  • 김명주;최정화
    • 한국의류학회지
    • /
    • 제23권5호
    • /
    • pp.726-736
    • /
    • 1999
  • The purpose of this study was to obtain the basal information for standard amount of clothing weight indoor climate and working condition with investigating seasonal changes of skin temperature and factors influencing on that in Koreans. Forty eight subjects in 5 age groups(6-11, 12-19, 20-44, 45-64, 65-76 years old) with both sexs were measured skin temperature indoor climate clothing microclimate clothing weight and skinfold thickness in neutral condition in each month throughout the year. The results obtained are summarized as follows : 1. Indoor climate koreans felt comfortable ranged 18.1-28.7$^{\circ}C$ and 51-74%RH. 2. Temperature inside the clothing ranged 30.8-32.3$^{\circ}C$ in males and 31.0-32.5$^{\circ}C$in females. There was a significant difference in temperature inside the clothing among age groups : That of 6019 age group was slightly higher than that at 45-76 age group. 3. Total clothing weight changed with season and increased in order of summer autumn spring and winter Total clothing weight of 65-76 age group was significantly greater on January and February. Breast skinfold thickness showed the smallest value in summer and the largest value in winter year. In addition to breast and abdomen skinfold thickness were larger in 45-67 age group while thigh skinfold thickness was larger in 6-19 age group. Skinfold thickness in females showed the smallest value in spring summer and the largest value in autumn and winter. In addition to triceps and suprailliac skinfold thickness were larger in 45-64 age group while thigh skinfold thickness was larger in 12-19 age goup. 5. Temperature of the lower limbs(hand, thigh. leg, and foot) showed significant correlation with the indoor temperature humidity inside clothing and total clothing weight. Temperature of the torso(breast and abdomen) showed significant correlation with the temperature inside clothing in all subjects. Abdomen skinfold thickness of all age group in male showed significant correlation with the abdomen skin temperature. triceps suprailliac and thigh skinfold thickness of 6-11 age group in female showed significant correation the upperarm abdomen and thigh skin temperature. Consequently clothing mdicroclimate total clothing weight and skinfold thickness showed significant difference in season sex and ages and had a slight effect on skin temperature.

  • PDF

의복재료와 상체부 의복형태변화가 의복내기후에 미치는 효과 (Effects of Fiber Type and Blouse Design on the Clothing Microclimate)

  • 김옥진;김용서;신윤숙;이영숙;정명선
    • 한국의류학회지
    • /
    • 제14권1호
    • /
    • pp.20-30
    • /
    • 1990
  • In order to investigate the mechanism of the formation of clothing microclimate with different blouse designs and materials, physiological and subjective sensational changes were measured. Experimental clothing were four types of blouse made of $100\%$ cotton, $100\%$ regular polyes­ter, and $100\%$ hygroscopic polyester. Four types of box style blouse were with stand collar and long sleeve, with stand collar and sleeveless, with long sleeve and collarless, and sleeveless and collarless. Five healthy female were chosen as subjects. Experiments were carried out in the environ­mental chamber controlled at $28{\pm}1^{\circ}C$ , $70{\pm}5\%$ RH. and still-air condition for SO min. The skin temperature (9 spots), oral temperature, humidity inside chest, and subjective sensations were measured. Obtained results are: I) Material which is capable of absorbing sweat effectively and transfering moisture rapidly made a comfortable feeling, because cloth­ing humidity is increasing slowly at this material. 2) During exercise period, covered arms have more influenced on thermal comfort than a covered neck.

  • PDF