• Title/Summary/Keyword: input power

Search Result 5,892, Processing Time 0.032 seconds

Static VAR Compensator Using PWM Voltage type Converter (PWM전압형 콘버어터에 의한 정지형 무효전력 보상장치)

  • 정연택;이훈구;황락훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.836-846
    • /
    • 1990
  • This paper presents a Static Var Compensator (SVC) system compensating the reactive power for power system, which consists of a voltage type Pulse Width Modulation (PWM) converter and a reactance linking the converter to the source. The system drives the four quadrant modes. The system determines the magnitude of the input voltage, and then compares it with the magnitude of the source voltage by regulating the phase of the SVC about the source. Therefore, the system generates leading compensation currents when the input voltage is larger than the source in magnitude, and lagging compensation currents for smaller input voltage. Reactive power about voluntary load in power system is smoothly compensated by those compensation currents, and also power factor of source is improved. Furthermore, the SVC system using PWM method may improve the source current waveforms by eliminating the 5th and 7th harmonic components from the input voltages.

  • PDF

Optimization of input carrier powers considering satellite link environment in the multi-level SCPC systems (Multi-level SCPC 시스템에서 링크환경을 고려한 중계기 입력반송파 전력의 최적화)

  • 김병균;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1240-1255
    • /
    • 1996
  • This paper suggests power optimization technique in multi-level SCPC system as a method for efficient utilization of limited satellite power. The power optimization is realized by optimal assignment of satellite input carrier powers considering interference and noise generated in up-link and down-link. The Fletcher-Powell algorithm searching minimum(or maximum) point using gradient information is used to detemine the optimal input carrier powers. To apply Flectcher-Powell algorithm mathematical descriptions and their partial derivatives to interference and nose are presented. Because a target, which should be optimized, is satellite input carrier power, amplitude of each carrier group will be assumed to be an independent variable. The performance criterion for optimal power assignmentis classified into 4 categories with respect to CNR of destination receiver earth station to meet the requirement for various satellite link environment. Simulation results for two-level, four-level and six-level SCPC system are presented.

  • PDF

A Resonant Type Inverter Power Conversion Equipment for Plasma Generator (플라즈마 발생장치용 공진형 인버터 전력변환장치)

  • Kim, Ju-Yong;Suh, Ki-Young;Mun, Sang-Pil;Jung, Jang-Gun;Kim, Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

THE POWER-FACTOR IMPROVEMENT FOR INPUT LINE OF THREE PHASE UNBALANCED LOAD (3상 불평형 부하에 대한 입력 역률 개선)

  • Jung, Yon-Taek;Seo, Young-Soo;Sung, Dae-Yong;Lim, Young-Bae;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.421-424
    • /
    • 1990
  • In this parer, the parameter for control variable is consist of value that take measured the input line current and input total power-factor, and the compensation susceptance is calculated by its parameters. The compensator can reduce the reactive power generation by the system to zero, thus the input total power-factor is kept on sustaining the unit power- factor.

  • PDF

A Study on Individual Tap-Power Estimation for Improvement of Adaptive Equalizer Performance

  • Kim, Nam-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • In this paper we analyze convergence constraints and time constant of IT-LMS algorithm and derive a method of making it's time constant independent of signal power by using input variance estimation. The method for estimating the input variance is to use a single-pole low-pass filter(LPF) with common smoothing parameter value, θ. The estimator is with narrow bandwidth for large θ but with wide bandwidth for small θ. This small θ gives long term average estimation(low frequency) of the fluctuating input variance well as short term variations (high frequency) of the input power. In our simulations of multipath communication channel equalization environments, the method with large θ has shown not as much improved convergence speed as the speed of the original IT-LMS algorithm. The proposed method with small θ=0.01 reach its minimum MSE in 100 samples whereas the IT-LMS converges in 200 samples. This shows the proposed, tap-power normalized IT-LMS algorithm can be applied more effectively to digital wireless communication systems.

A Study of AC-DC PWM Full-Bridge Integrated Converter Topologies

  • Gerry, Moschopoulos;Praveen Jain
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.107-116
    • /
    • 2001
  • Two AC-DC PWM full-bridge converters that can input current to improve input power factor while performing dc-dc conversion are investigated in this paper. Both converters are simple in that they are similar to the standard PWM full-bridge converter with a diode rectifier/LC low-pass filter input, and both can operate with a simple method of PWM control. In the paper, the operation of the converters is explained and their steady-state characteristics are discussed. The feasibility of the converters and their ability to meet EN61000-3-2 Class D Standards for electrical equipment are shown with results obtained from experimental prototypes. The performance of both converters in terms of dc bus voltage level, input power factor and efficiency is compared and discussed.

  • PDF

A study on power system for plasma sterilization (플라즈마 살균용 전원장치에 관한 연구)

  • Kang, W.J.;Kim, Y.M.;Mun, S.P.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Effects of Imperfect Sinusoidal Input Currents on the Performance of a Boost PFC Pre-Regulator

  • Cheung, Martin K.H.;Chow, Martin H.L.;Lai, Y.M.;Loo, K.H.
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.689-698
    • /
    • 2012
  • This paper investigates the effects of applying different input current waveshapes on the performance of a continuous-conduction-mode (CCM) power-factor-correction (PFC) boost pre-regulator. It is found that the output voltage ripple of the pre-regulator can be reduced if the input current is modified to include controlled amount of higher order harmonics. This finding allows us to balance the performance of output regulation and the harmonic current emission when coming to the design of the pre-regulator. An experimental PFC boost pre-regulator prototype is constructed to verify the analysis and show the benefit of the pre-regulator operating with input current containing higher order harmonics.

Resonance inverter power system for plasma sterilization effective improvement (플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템)

  • Kim, J.Y.;Mun, S.P.;Kim, J.S.;Kim, Y.M.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Resonance Inverter Power System for Sterilization Effective Improvement of Plasma (플라즈마 살균 효과 향상을 위한 공전형 전원 시스템)

  • 김주용;문상필;정장근;이현우;서기영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF