• Title/Summary/Keyword: inlet pressure

Search Result 1,649, Processing Time 0.03 seconds

Investigation of the Performance of the Alternative Refrigerant HFC-134a through Capillary tube : Numerical Analysis (대체냉매 HFC-134a의 모세관 성능에 관한 수치해석적 연구)

  • Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.169-178
    • /
    • 1993
  • Performance charts of capillary tubes for R-134a are presented. The calculation is based on the one-dimensional, adiabatic flow through capillary tube. The length of capillary tube changes with inlet pressure, mass flux, inlet quality(or subcooling), and inside diameter. The length for R-134a is shorter by 12.5~23% than that for R-12 as mass flux varies, by 13~18.5% as inlet pressure changes, by 15~15.2% as inside diameter changes, and by 3.6~20% as subcooling(or quality) changes. In general, the length for R-134a is shorter than that for R-12 by 10~20%. Pressure drop per unit length for R-134a is greater than that for R-12 since specific volume of R-134a is larger that of R-12 and vapor pressure of R-134a is greater than that of R-12. Flash point of R-134a is ahead of that of R-12.

  • PDF

Effect of Operating Conditions on the Fouling of UF Membrane in Treatment of Dissolved Organic Matter (UF를 이용한 용존성 유기물질 제거시 운전조건이 파울링에 미치는 영향)

  • Kwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1183-1191
    • /
    • 2000
  • Operating conditions for reduction of membrane fouling in treatment of dissolved organic matter by UF membrane process were investigated by pilot-scale plant using various operating conditions. As inlet pressure increased, increament of transmembrane pressure and flux decline were faster. The reason was due to the increase in adsorption of dissolved organic matter and the development of cake layer compression on the membrane surface. When efficient pressure (the difference of pressure between backwash and transmembrane pressures) was high, small amount of pollutant was retained on the membrane surface. When backwash was frequently conducted, low concentration of pollutant was maintained in recycling water. Therefore, backwash could be efficiently conducted with high efficient pressure and high frequency. Fouling rate was correlated with backwash and inlet pressures, recovery rate and cumulative permeated volume. Among the operating parameters backwash pressure was most closely related to fouling rate and inlet pressure was next to backwash pressure. It seems that the fouling was strongly related to pressure which leads to the cake layer compression and adsorption of dissolved organic matter.

  • PDF

Evaluation of Inflow Uniformity on the Performance of Double-Inlet Centrifugal Blower Using Optimal Design Method (양흡입 원심블로어 성능향상을 위한 입구 유동 최적화 연구)

  • Lee, Jong-Sung;Jang, Choon-Man;Jeon, Hyun-Jun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.4
    • /
    • pp.326-333
    • /
    • 2013
  • This paper presents the performance enhancement of a double-inlet centrifugal blower by the shape optimization of an inlet duct. Two design variables, a length of anti circulation vane and an angles of inlet guide, are introduced to improve the inlet flow uniformity leading to the blower performance. Three-dimensional Navier-Stokes equations are used to analyze the blower performance and the internal flow of the blower. From the shape optimization of the inlet duct of the double-inlet centrifugal blower, the optimal positions of each design variable are determined. Throughout the analysis of sensitivity, it is found that the angle of the inlet guide is more effective than the length of the anti-circulation vane to increase flow uniformity at the outlet of the duct. Efficiency and pressure for the optimal inlet duct shape are successfully increased up to 3.55% and 3.2% compared to those of reference blower at the design flow condition, respectively. Detailed flow field inside the blower is also analyzed and compared.

Study on Optimization of Throttle Margin in High Pressure Turbine of Nuclear Power Plant (원자력 발전소 고압터빈의 교축여유(Throttle Margin) 최적화 연구)

  • Ko, W.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • In the present study, optimization of throttle margin for high pressure turbine to be retrofitted or partially modified for power uprating or life extension in nuclear power plant, has been performed to increase the electrical output. Throttle margin for high pressure turbine is required to maintain all the time the rated power by opening more of governor valves whenever inlet pressure is decreased due to the tube plugging of steam generator. If throttle margin of high pressure turbine is too much compared to remaining lifetime, loss of electrical output due to pressure drop of governor valves is inevitable. On the contrary, if it is too little, the rated power operation can not be accomplished when inlet pressure of high pressure turbine is dropped after many years operation. So, throttle margin for high pressure turbine in nuclear power plant is compromised considering for the degradation of steam generator, governor valve capacity, manufacturing tolerance of high pressure turbine, future plan of power uprating, and remaining lifetime of power plant.

An Experimental Study on the Spray Characteristics of the Pressure Swirl Atomizer (신회유동을 갖는 압력식 분무기의 분무특성에 관한 연구)

  • Cho, D.J.;Yoon, S.J.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.46-51
    • /
    • 1997
  • In this study, spray characteristics of the pressure swirl atomizer have teen investigated. Four atomizers with the different orifice diameter and five tangential ports with the different inlet number were fabricated. For the purpose of the measurement of the mean drop sine, Malvern particle sizer was used. And also discharge coefficient was measured and spray cone angle was measured by using shadow graphy method. As a result when the injection pressure was increased, mean drop size was decreased. And the dominant factor which influence on the spray characteristics of pressure swirl atomizer was orifice diameter.

  • PDF

A Study on Pressure Drop in Vortex Amplifier (와류증폭기에서의 압력강하에 관한 고찰)

  • Park, Jun Sang
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • An analysis on pressure drop in vortex amplifier has been performed. Based on theoretical approach with flow physics on well-known firm ground from previous studies, two dimensional flow model, which is very useful to calculate pressure drop of vortex amplifier, is proposed. Parametric studies on inlet and outlet boundary conditions also have been performed so that it found the most influential parameter is the inlet swirl velocity condition. Finally, a simple formulation is given to calculate total pressure drop.

Development of Block type Inlet Distortion Simulating Device for Gas Turbine Engine Inlet Distortion Test

  • Lee, Kyung-Jae;Lee, Bo-Hwa;Kang, Sang-Hun;Jung, Jae-Hong;Yang, Soo-Seok;Lee, Dae-Sung;Kwak, Jae-Su
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.121-125
    • /
    • 2007
  • In late 1960's, engineers of the engine manufacturer experienced that the distortion of inlet flow of turbofan and turbojet engine could cause the surge in compressor and affect overall engine operational performance, which result in the deterioration of stability of the engine. In this study, block type of inlet distortion simulating device has been developed in order to investigate the effect of inlet distortion on the deterioration of overall engine operational performance. The inlet distortion simulating device was installed in front of engine inlet in order to simulate distortion of inlet flow. The degree of inlet distortion was measured by rakes installed upstream the inlet distortion simulating device and between the engine inlet and inlet distortion simulating device. Before applying the inlet distortion simulating device to real engine, preliminary tests were performed with a simulated engine in order to verify the degree of inlet distortion by the device. Preliminary inlet distortion tests were performed in Altitude Engine Test Facility(AETF) of Korea Aerospace Research Institute(KARI) and results showed that the inlet distortion simulating device could be used in simulating various inlet distortion cases.

Shape Optimization of Inlet Part of a PCHE (인쇄형 열교환기 입구부의 최적설계)

  • Koo, Gyoung-Wan;Lee, Sang-Moon;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.2
    • /
    • pp.35-41
    • /
    • 2013
  • Inlet part of a printed circuit heat exchanger has been optimized by using three-dimensional Reynolds-Averaged Navier-Stokes analysis and surrogate modeling techniques. Kriging model has been used as the surrogate model. The objective function for the optimization has been defined as a linear combination of uniformity of mass flow rate and the pressure loss with a weighting factor. For the optimization, the angle of the inlet plenum wall, radius of curvature of the inlet plenum wall, and width of the inlet pipes have been selected as design variables. Twenty six design points are obtained by Latin Hypercube Sampling in design space. Through the optimization, considerable improvement in the objective function has been obtained in comparison with the reference design of PCHE.

Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner (PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

Transmission Loss Analysis of Simple Expansion Chambers with Multiple Inlets and Outlets (다입력/다출력관을 갖는 확장관의 투과손실 해석)

  • 박기춘;김양한
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.807-813
    • /
    • 1998
  • Transmission loss of the simple expansion chamber with multiple inlet and outlet ports is obtained. Transfer matrices which represent the relation between the power variables(pressure and velocity) of inlets and outlets depend on the input relatons as well as the acoustic system parameters(i.e. geometry of the chamber, wall admittance, etc.). The analysis has been performed analytically, including the effects of higher order modes for the 2-inlet/1-outlet, 1-inlet/2-outlet and 2-inlet/2-outlet systems. This study yeilds that phase difference between the inlet ports can significantly increase the transmission loss in low frequency range.

  • PDF