• 제목/요약/키워드: inlet loading rate

검색결과 50건 처리시간 0.021초

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF

Simultaneous Removal of Hydrogen Sulfide and Ammonia Using Thiobacillus sp. IW in a Three-Phase Fluidized-Bed Bioreactor

  • Kum, Sung-Hoon;Oh, Kwang-Joong;Moon, Jong-Hae;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제10권3호
    • /
    • pp.419-422
    • /
    • 2000
  • A three-phase fluidized-bed bioreactor including Thiobacillus sp. IW was tested to remove H_2S and $NH_3$ simultaneously. The inlet $H_2S$ was oxidized to $SO_4^{2-}$ by Thiobacillus sp. IW, and the $NH_3$ reacted with the $SO_4^{2-}$ to form $(NH_4)_2SO_4$. The removal efficiency of $H_2S$ was 98.4-99.9% for an inlet concentration of 36-730 ppm and that of $NH_3$ was 60.2-99.2% for an inlet concentration of 45-412 ppm. The removal efficiency of $NH_3$ was reduced when the inlet loading rate of $NH_3$ was increased above 10 mg/l/h. When the bioreactor was operated for 25 days with a lower inlet concentration of $NH_3$ compared with the of $H_2S$, the bioreactor exhibited an excellent performance with a stable pH, dissolved oxygen content, and cell concentration.

  • PDF

황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거 (A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate)

  • 서정민
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

탈질 조건에서 투과매질 내 미생물 성장에 관한 연구

  • 최영화;오재일;배범한
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.366-369
    • /
    • 2002
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Most biobarrier studies were conducted under aerobic condition, however there were several obstacles to make aerobic condition. Thus, In this study, we examined biobarrier formation under denitrifying condition by using nitrate as an electron acceptor. Experiments were performed with a sand column inoculated with activated sludge from the nearby WWTP. The substrate medium was pumped to the sand column in an upflow mode. During the low substrate loading rate period, the extent of reduction rate in hydraulic conductivity was found similar throughout the column, and permeability became relatively stable after couple of days. However, during the high substrate loading rate period, the column demonstrated a gradient of permeability reduction, with the greatest reduction in sections nearest the column inlet. Rapid growth of microorganisms near the column inlet resulted in the unbalanced reduction of hydraulic conductivity throughout the sand column. As a result, at this denitrifying condition the thickness of biobarrier could be controlled by adjusting the medium conditions of microbial growth.

  • PDF

이단미생물반응조에서 혼합 VOCs의 생분해 특성 (Biological Removal of a VOC Mixture in a Two-stage Bioreactor)

  • 송지현
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.758-766
    • /
    • 2006
  • A two-stage bioreactor, which consists of a biotrickling filter module and a biofilter module in series, was investigated for the enhanced treatment of a VOC mixture, toluene and methyl ethyl ketone (MEK). Throughout the experiments, the overall inlet loading rate was maintained at approximately $43g/m^3/hr$, but the inlet ratios of the VOCs were modified. The experimental results showed that the different ratios of the VOC mixture resulted in changes of overall removal efficiencies, elimination capacities (ECs) and microbial accumulation on the surface of each packing material. The ratio of inlet toluene to MEK at 50 : 150 was found to be most effective in terms of the overall removal efficiency, because, at this condition, MEK (i.e., the hydrophilic compound) was mostly removed in the biotrickling filter module and the following biofilter module was used to remove toluene. It was also found that when the inlet loading rate of the VOC mixture was serially increased stepwise within short-term periods, the ECs for toluene dropped significantly but the ECs for MEK increased at the ratio of the VOC mixture. These results implied that substrate interaction and/or substrate preferable utilization might have an effect on the biological removal of each compound in the two-stage bioreactor; therefore, the bioreactor should be operated in the condition where the substrate interaction could be minimized in order to maximize overall performance of the two-stage bioreactor.

3상 생물막유동층반응기를 이용한 황화수소와 암모니아의 동시제거

  • 박진수;문종혜;김종우;김동욱;오광중
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.339-342
    • /
    • 2000
  • 황화수소와 암모니아 함유악취의 동시처리를 위해 Thiobacillus sp.IW가 함유된 3상 생물막유동층반응기를 사용하였다. 본 연구에서 황화수소는 미생물에 의해 산으로 전환되었으며 이어서 유입된 암모니아와 반응하여 황산암모늄이 생성됨으로서 양성분은 제거되었다. 황화수소의 경우 45 mg/l h의 유입량에서도 거의 완전한 처리 효율을 보여주었으나, 암모니아의 경우 유입량이 10 mg/l h에서 증가함에 따라 처리효율은 점차 감소하였다.

  • PDF

전기히터방식 매연여과장치의 PM 산화 특성에 관한 연구 (A Study on the PM Oxidation Characteristics of Electrical Heater DPF System)

  • 함윤영;김대하;김경운
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.183-190
    • /
    • 2006
  • For continuously regenerative PM collecting system which adopted thermally stable SiC DPF and electrical heater which was placed upstream of the filter and driven by well constructed control logic, PM oxidation characteristics were investigated varying air flow rate, amounts of PM accumulated on the DPF and filter inlet temperature in order to get optimized PM regeneration performance. This study showed that the operating condition of air flow rate 70 lpm, high PM loading around 30g and filter inlet temperature $700^{\circ}C$ with heat insulation was effective in achieving high regeneration efficiency. Also, in this condition, we could decrease the electric energy consumption by reducing the regeneration time.

EFFECT OF INLET LOADING RATE ON THE ELIMINATION OF HYDROGEN SULFIDE AND AMMONIA IN IMMOBILIZED CELL BIOFILTERS

  • Kim, Jung-Hoon;Rene, Eldon R.;Park, Seung-Han;Park, Hung-Suck
    • Environmental Engineering Research
    • /
    • 제11권5호
    • /
    • pp.285-291
    • /
    • 2006
  • Biofiltration is a simple, effective, economically viable and the most widely used gas treatment technique for treating malodors at low concentrations and high flow rates. This paper reports the performance of two lab scale immobilized cell biofilters operated in continuous mode for hydrogen sulfide ($H_2S$) and ammonia ($NH_3$) removal. The removal efficiency (RE, %) and the elimination capacity (EC, $g/m^3{\cdot}hr$) profiles were monitored by subjecting the biofilters to different loading rates of $H_2S$ (0.3 to $8\;g/m^3{\cdot}hr$) and $NH_3$ (0.3 to $4.5\;g/m^3{\cdot}hr$). The removal efficiencies were greater than 99% when inlet loading rate to the biofilters were upto $6\;gH_2S/m^3{\cdot}hr$ and $4\;gNH_3/m^3{\cdot}hr$ respectively. The performance of the biofilters were also ascertained by conducting shock loading studies at a loading rate of $10\;gH_2S/m^3{\cdot}hr$ and $6\;gNH_3/m^3{\cdot}hr$. The results from this study show high removal efficiency, good recuperating potential and stability of the immobilized microbial consortia to transient shock loads.

ROADMOD를 이용한 도로청소 및 모래여과시설에 의한 고속도로에서의 강우시 TSS 저감효과 분석 (Removal Efficiency of TSS Loadings from Expressway by Road Sweeping and Sand Filter Facility Using ROADMOD)

  • 강희만;전지홍
    • 한국물환경학회지
    • /
    • 제39권1호
    • /
    • pp.38-45
    • /
    • 2023
  • In this study, the removal efficiency of road sweeping and sand filter facility for removing total suspended solid (TSS) as nonpoint source pollution from expressway was evaluated for the last 10 years (2012~2021) using ROADMOD. ROADMOD is a screening level model and was calibrated for runoff rate and TSS loading both at the inlet, which is the loading from the drainage area, and the outlet, from the sand filter facility. The drainage area is 715 m2 and the dimensions of sand filter facility are 1.5 m (wide) × 3.8 m (length) × 1.5 m (depth). The monitoring period for model calibration was the rainfall event during Aug. 31~Sep. 1, 2021 and the amount of rainfall was 74.5 mm. As a result of calibration, the determination coefficients (R2) of the flow rate were 0.66 and 0.86, for the inlet and outlet, respectively, and those of TSS loading were 0.50 and 0.84, for the inlet and outlet, respectively. Considering that ROADMOD is a screening level model, the calibration results were reasonable to evaluate the best management practices (BMPs) on the expressway. Using ROADMOD simulation results for 2012~2021, the average yearly runoff rate from the expressway was 82% and removal efficiency was 9% for road sweeping, 35% for sand filter facility, and 39% for both road sweeping and sand filter facility.

디젤 입자상물질 후처리 장치에서 입자상물질의 연소에 미치는 재생 인자의 영향 (Effects of Regeneration Parameters on Oxidation of Particulate in a Diesel Particulate Trap System)

  • 김재업;조훈;김형욱;박동선;유천;김응서
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.168-177
    • /
    • 1998
  • The effects of the regeneration parameters such as inlet gas temperature, space velocity, oxygen concentration of the exhaust gas, and initial particulate loading on the oxidation of the particulate inside ceramic cordierite filter have been investigated through an engine experiment. As the inlet gas temperature increases, the remarkable filter temperature occurs owing to the rapid combustion rate. Though the higher space velocity affirms the safe regeneration, it also requires much fuel consumption of the burner. For that reason, the space velocity should be compromised considering the fuel economy. The excessive accumulation of the particulate may cause undesirable regeneration temperatures inside filer even under the optimized regeneration condition. The inlet gas temperature should be selected to overcome the variation of the oxygen concentration which is inherent feature of the diesel engine. It is the most important factor in the regeneration control techniques.

  • PDF