• 제목/요약/키워드: ink

검색결과 1,443건 처리시간 0.024초

국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가 (Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea)

  • 황양인;이미영;정윤경;김은아
    • 분석과학
    • /
    • 제26권5호
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

비점착성 사면에 인접한 대상기초의 지지력 (Bearing Capacity of Strip Footing Adjacent on Cohesionless Slopes)

  • 유남재;김영길;전연종
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.37-54
    • /
    • 1997
  • 본 논문은 비점착성 사질토 성토 사면에 인접한 대상기초의 극한지지력 및 파괴메카니즘에 관 한 연구로서 지반의 상대밀도, 기초 폭, 사면 경사각, 사면 정부로 부터 기초까지의 거리가 기초 의 하중침하특성과 극한지지력, 경사지반의 파괴메카니즘에 미치는 영향을 조사하기 위하여 비 점착성 사질토 모형사면에서 2차원 평면변형 실험을 수행하였다. 모형실험에서는 주문진 표준사를 사용하여 상대밀도가 45%와 70%로 조성된 1:1.5및 1:2의 모형사면을 성형하고 폭이 4, 7, 10, 12cm의 대상 강성 모형기초를 사용하였다. 또한 기초의 재하위치는 사면 정부로 부터 기초까지의 거리를 기초 폭으로 나눈 값 즉, 0, 0.5, 1, 2, 3, 4, 5로 변화시키면서 실험을 수행하였다. 이와같이 사면 정부로 기초의 재하위치를 점진적으로 변화시키므로써 관찰된 활동선 형성의 파괴메카니즘을 기존의 해석 방법들과 비교 분석하였으며, 실험을 수행하여 측정한 극한지지력을 한계평형법과 극한해석법 그리고 실험결과에 의한 경험식과 비교하여 지반의 상대밀도, 기초의 폭 및 기초 재하위치의 변화가 극한지지력 및 하중친하 특성, 파괴메카니즘에 미치는 영향을 조사하였다.

  • PDF

재식한 흰쥐 구치 치수조직의 재혈관화와 CGRP 면역반응 신경섬유의 변화 (REVASCULARIZATION AND REINNERVATION OF CALCITONIN GENE-RELATED PEPTIDE IMMUNOREACTIVE NERVES IN REPLANTED RAT MOLARS)

  • 이승봉;김현정;남순현;배용철;김영진
    • 대한소아치과학회지
    • /
    • 제26권4호
    • /
    • pp.688-702
    • /
    • 1999
  • 치아 재식 후 시간경과에 따른 치수조직의 재혈관화와 신경재지배의 변화를 관찰하기위해 생후 35일 된 흰쥐 (Sprague dawley) 56마리를 대상으로 상악우측 제 1대구치를 발치 즉시 재식한 후 1일, 2일, 3일, 1주, 2주, 4주, 6주 간격으로 희생시켜 먹물을 이용한 혈관조영술과 CGRP를 이용한 면역조직화학적방법으로 각기 시행하여 다음과 같은 결론을 얻었다. 1. 재혈관화와 CGRP 면역반응신경섬유의 재지배는 재식후 1일에서 근심측 치수조직에서는 이미 이루어졌으나 원심측은 미약했다. 재식후 2일에 전치수조직에서 재혈관화와 신경재지배가 이루어졌으며 이후 6주까지 시간경과에 따라 분포밀도가 증가하였으나 대조군에 비해서는 약하게 나타났다. 2. 재식후 1주에서부터 술후 상아질이 형성되기 시작하였으며 재식후 6주에서는 대조군에 비해 상대적으로 치수강이 좁아진 양상을 보였다. 3. 재혈관화와 신경재지배는 거의 같은 시기에 이루어지는 것으로 나타났으며 밀접한 관련성이 있는 것으로 보인다.

  • PDF

Ca(OH)2-CH3OH-H2O-CO2계에서 바테라트의 생성에 미치는 반응온도의 영향 (Effect of Temperature on the Formation of Vaterite in Ca(OH)2-CH3OH-H2O-CO2 System)

  • 박종력;최상근;김병곤;이재창
    • 한국세라믹학회지
    • /
    • 제39권12호
    • /
    • pp.1143-1148
    • /
    • 2002
  • 침강성 탄산칼슘은 충진용으로 매우 유용하며 제지, 페인트, 플라스틱, 고무, 잉크 등 광범위한 공업분야에 사용되고 있다. 탄산칼슘은 켈사이트, 아라고나이트, 바테라이트의 세 가지 동질이상이 존재하며 그중 바테라이트는 천연적으로 산출되지 않는 것으로 알려져 있다. 본 연구에서는 $Ca(OH)_2-CH_3OH-H_2O-CO_2$계에서 바테라이트 분체를 합성하고자 하였으며, 이때 반응도중 슬러리의 전기전도도, pH, $Ca^{2+}$ 이온농도 등을 측정을 행하였다. 반응이 종료된 후 최종생성물은 XRD 및 SEM을 이용하여 분석하였다. 실험결과 반응온도 50${\circ}C$ 이상에서는 바테라이트와 함께 켈사이트, 아라고나이트가 혼재하게 됨을 알 수 있었으며 순수한 바테라이트를 합성하기 위해서는 반응온도를 40-50${\circ}C$의 범위로 유지해야 함을 알 수 있었다. 또한 반응온도가 40${\circ}C$에서 50${\circ}C$로 증가함에 따라 생성되는 입자의 평균입도를 0.5 ${\mu}m$에서 0.8 ${\mu}m$까지 성장시킬 수 있음을 확인하였다.

근관치료시 Nd:YAG Laser 사용과 세척액에 따른 치근단 폐쇄효과의 비교 (THE EFFECTS OF ND:YAG LASER AND IRRIGANTS ON CANAL SEALING ABILITY)

  • 김진운;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.307-315
    • /
    • 2001
  • The application of Nd:YAG laser and irrigants to the root surface can change its surface configurations. The purpose of this study was to investigate the effects of Nd:YAG laser and irrigants on the apical seal of obturated canals. In this study, 66 single rooted teeth were randomly assigned to 4 group of 14 teeth each. 8 teeth were served us positive and negative controls. The teeth were divided into 6 groups as follows. Group A: Nd:YAG laser, 5% NaOCl + Rc-prep Group B: Nd:YAG laser, Saline Group C: 5% NaOCl + Rc-prep Group D: Saline Group E: Positive control Group F: Negative control 66 teeth were instrumented using Maillefer ProFile$^{\circledR}$ (Orifice Shapers, .04 taper, .06 taper Dentsply, Switzerland). Two of each group were selected at random, and the canal wall surfaces were examined under a SEM. 12 teeth of each group were obturated using by lateral condensation technique. Specimens were immersed in india ink for 7days, decalcified by 10% nitric acid, dehydrated by 75. 80. 85, 90, 95 and 100% alcohol in order cleared by methyl salicylate and then measured of dye penetration with stereomicroscope($\times$15 magnification) and Image Pro plus. The data were analyzed statistically by one-way ANOVA test and Duncan's Multiple Range test. The results were as follows : 1. The mean leakage was 0.128$\pm$0.376 for group A, 0.237$\pm$0.325 for group B, 0.397$\pm$0.468 for group C, 0.586$\pm$0.402 for group D, and there were statistically significant differences between group A and group D, group B and group D. (p<0.05). 2. Group A had better sealing ability than Group C, but there was statistically no significant differences. (p>0.05). 3. Group B had better sealing ability than Group D and there was statistically significant difference. (p<0.05). 4 Group A had better sealing ability than Group B, but there was statistically no significant difference. (p>0.05). 5. Group C had better sealing ability than Group D, but there was statistically no significant difference. (p>0.05). 6. As a result of observation under SEM, Smear layers were removed in Group A, B. but Smear layers were partially removed and smear plugs were remained in Group C, Smear layers were not removed in Group D. To be specially, Melting of smear layer were showed in Group C. 7. These results suggests that the laser has a potential in reducing the apical microleakage of obturated canals.

  • PDF

비스무스와 지르코늄 첨가를 통한 세리아계 친환경 노란색 안료 특성에 관한 연구 (Effect of Bi and Zr addition on yellow colour properties of environment-friendly ceria-based pigments)

  • 김태호;황해진;김진호;황광택;한규성
    • 한국결정성장학회지
    • /
    • 제25권4호
    • /
    • pp.153-159
    • /
    • 2015
  • 무기안료는 우수한 열적, 화학적 안정성으로 인해 페인트, 고화도 세라믹 잉크, 아트 타일, 건물의 외장재 등의 다양한 응용 분야에 적용될 수 있어 큰 관심을 받고 있다. 기존에는 $PbCrO_4$, CdS, CdSe 등의 조성이 노란색 무기 안료로 널리 사용되어 왔으나 Cd, Cr, Pb, Se 같은 유해물질을 포함하고 있어 최근에는 사용에 제한되고 있다. 따라서 본 연구에서는 ceria 기반의 조성을 이용하여 고상법으로 친환경 노란색 무기안료를 합성하였다. XRD와 SEM을 통해 합성된 $Ce_{1-x}Zr_xBi_yO_{2-y/2}$ 노란색 무기안료의 결정구조와 형상을 확인하였고, UV-vis. spectrophotometer와 CIE $L^*a^*b^*$ 분석으로 Zr과 Bi함량에 따른 노란색 무기안료의 발색 특성 변화를 확인하였다. 노란색 무기안료의 결정구조는 주로 하소온도의 변화에 의존하는 것으로 확인되었고, 발색 특성과 흡수단은 하소온도와 Zr, Bi 함량이 모두 영향을 미치는 것으로 나타났다. 결과적으로 합성된 모든 무기안료는 자외선과 500 nm 이하의 가시광선을 효율적으로 흡수하였고, $Ce_{0.44}Zr_{0.36}Bi_{0.20}O_{0.19}$(x = 0.36, y = 0.20) 조성의 무기안료에서 가장 선명한 노란색 색조를 확인할 수 있었다.

Astaxanthin처리 산란계로부터 생산된 난황이 Mouse의 마크로파지 활성과 응집소가 및 용혈소가에 미치는 영향 (Effect of the Egg Yolks from Laying Hens Intubated Astaxanthin on the Macrophage Activity, Hemagglutinin-titer and Hemolysin-titer)

  • 김홍출;박숙자;김정곤;김영림;박원석;조용운;조현종;김정환;하영래
    • 한국식품영양과학회지
    • /
    • 제30권6호
    • /
    • pp.1283-1286
    • /
    • 2001
  • 마크로파지의 활성을 조사하기 위해 carbon clearance time을 조사한 결과 AEY 처리구가 control이나 CEY 처리구에 비해 짧았다. 특히 AEY 500$\mu\textrm{g}$ 처리에서 carbon clearance 시간이 5분으로 control에서 9.42분, CEY(250$\mu\textrm{g}$ 처리)에서 9.01분보다 유의성 있는 감소를 보였다. AEY 처리에 의해 응집소가와 용혈소가가 다소증가되었다. SRBC처리 1일째와 3일째에 250$\mu\textrm{g}$ 처리구를 비교해 보면, control, CEY, AEY의 응집소가는 각각 5.50, 5.63, 6.00 및 5.25, 5.38, 5.50로 용혈소가는 각각 4.75, 5.38, 5.50 및 4.25, 5.63, 5.63으로 AEY 처리구가 control, CEY 처리구에 비해 면역 활성이 있었지만 유의성은 없었다.

  • PDF

차기구축함 통합마스트에 적용을 위한 전자기파 메타물질 흡수체의 온도 환경 내구성 검증 (Verification of Durability of Electromagnetic Metamaterial Absorber in Temperature Varying Environment for Its Application to Integrated Mast of Next-Generation Destroyer)

  • 라영은;김용준;정현준;박평원;조정대;이준식;김명준;정준교;이건민;이종학;이학주
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.347-353
    • /
    • 2020
  • 본 논문에서는 차기구축함에 탑재될 통합 마스트의 레이더 반사면적을 감소시킬 수 있는 스텔스 기술로 응용하기 위해 해양 환경이 모사된 온도 환경 조건에서 전자기파 메타물질 흡수체의 내구성을 검증하였다. 이를 위해 미국 군사 규격인 MIL-STD-810H의 Method 501.7 중 Procedure I 조건에 따라 주기적으로 온도를 조절할 수 있는 항온 챔버에 저장 후 전자기파 메타물질 흡수체의 반사도를 측정하였다. 고온 환경시험 전과 후 모두 X 밴드 전체에서 스텔스 성능을 충족시킬 수 있는 -10 dB 미만의 반사도가 확인되었다.

전기영동 디스플레이용 대전 복합입자의 제조 (Preparation of Charged Composite Particles for Electrophoretic Display)

  • 라해진;백정주;김지숙;김성수
    • 폴리머
    • /
    • 제33권4호
    • /
    • pp.347-352
    • /
    • 2009
  • 전자종이 등 전기영동을 이용한 디스플레이 기술에 사용하기 위한 대전 입자를 유무기 복합 형태로 제조하였다. $TiO_3$$Co_3O_4$를 core 입자로 사용하여 Poly(methyl methacrylate)를 분산 중합으로 코팅하였다. 또한, 코팅 고분자에 charge moiety를 부여하여 $TiO_2$ core 입자는 양전하의 복합입자로 $Co_3O_4$ core 입자는 음전하의 복합입자로 제조하였다. 제조된 대전입자는 중합 후 구형의 형태를 갖게 되었음을 전자현미경을 통하여 확인을 하였다. 대전 복합입자를 전기영동에 사용하기 위하여 전기영동 유체와 유사한 밀도를 갖도록 조절하였다. $TiO_2$ 입자의 밀도는 고분자 코팅 전후 4.02 g/$cm^3$에서 1.44 g/$cm^3$로 변화하였고, $Co_3O_4$ 입자의 경우 입자의 밀도가 6.11 g/$cm^3$에서 1.49 g/$cm^3$로 변화하였다. Urea, melamine, formaldehyde를 벽물질로 하여 흑백 입자를 각각 포함하는 microcapsule을 in-situ polymerization 방법으로 제조하였으며, 균일한 크기와 투명한 microcapsule이 제조되었음을 video 현미경을 통하여 확인하였다.

의료용 표시기의 안전성 및 성능 평가를 위한 시험 항목 및 시험방법(안)연구 (Development of Standards of Tattoo Machine for Safety and Performance Evaluation)

  • 김영균;조승관;이태우;여창민;정병조;권영미;차지훈;허찬희;박기정;김동섭;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.151-157
    • /
    • 2011
  • Tattooing is a performance for decorative and cosmetic marking by placing permanent ink into the skin. As the cultural meaning of tattoo in Korea is changing, the tattoo machines are widely spread n permanent cosmetic market. Though the use of the tattoo machine was increased, the evaluation standards of tattoo machine were not existed. Korea Food and Drug Association regulated the electrical and mechanical safety standards which were founded on the IEC 601-1 second edition. Also they regulated he biological safety standards which were derived from the ISO 10993 series, however, these general valuations of common medical device were insufficient for evaluating tattoo machine. We developed the standards of tattoo machine for safety and performance evaluation for tattoo machine by preliminary hazard analysis in ISO 14971. The evaluation criteria of tattoo machines are focused on the mechanical invasion. We suggested the additional evaluation items of the needle speed, length, vibration with general valuation criteria of common medical device. We anticipate that this research may be a primary stage to figure a standard regulation and evaluation for tattoo machine.