• 제목/요약/키워드: injection detection

검색결과 486건 처리시간 0.027초

축산식품 중 비스테로이드성 항염증 약물의 잔류함량 모니터링 (Mornitoring of non-steroidal anti-inflammatory drugs in livestock products)

  • 최윤화;김연주;신방우;이정학
    • 한국동물위생학회지
    • /
    • 제34권3호
    • /
    • pp.285-289
    • /
    • 2011
  • This study was conducted to determine the content of non-steroidal anti-inflammatory drugs (NSAIDs) in meats available on the Korean markets. The analysis was carried out using following conditions; C18 column ($100{\times}2.1$ mm, 1.7 ${\mu}m$), mobile phase composed of DW (containing 0.1% formic acid): acetonitrile (containing 0.1% formic acid), binary pump at a flow rate of 0.3 ml/min and 5 ${\mu}l$ of injection volume, MS/MS detector with ESI positive mode. The calibration range of five NSAIDs showed linearity ($r^2{\geq}0.99$) at concentration range of 3.125~200 ${\mu}g$/kg. The recoveries in fortified muscle more than 78.7~100.3%. The detection limits for meloxicam, ketoprofen, flunixin, carprofen and tolfenamic acid were 3.5, 1.6, 1.7, 9.8 and 4.8 ${\mu}g$/kg, respectively. We also monitored NSAIDs residue in cattle muscle 51 samples. The test results, NSAIDs were all not founded.

Pulse Counting Sensorless Detection of the Shaft Speed and Position of DC Motor Based Electromechanical Actuators

  • Testa, Antonio;De Caro, Salvatore;Scimone, Tommaso;Letor, Romeo
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.957-966
    • /
    • 2014
  • Some of DC actuators used in home automation, office automation, medical equipment and automotive systems require a position sensor. In low power applications, the introduction of such a transducer remarkably increases the whole system cost, which justifies the development of sensorless position estimation techniques. The well-known AC motor drive sensorless techniques exploiting the fundamental component of the back electromotive force cannot be used on DC motor drives. In addition, the sophisticated approaches based on current or voltage signal injection cannot be used. Therefore, an effective and inexpensive sensorless position estimation technique suitable for DC motors is presented in this paper. This technique exploits the periodic pulses of the armature current caused by commutation. It is based on a simple pulse counting algorithm, suitable for coping with the rather large variability of the pulse frequency and it leads to the realization of a sensorless position control system for low cost, medium performance systems, like those in the field of automotive applications.

Determination of Heparin Using Norfloxacin-cerium Complex as a Fluorescence Probe by Spectrofluorimetry

  • Patil, Shailaja R.;Mote, Umesh S.;Patil, Shivajirao R.;Kolekar, Govind B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권12호
    • /
    • pp.3034-3038
    • /
    • 2009
  • A simple, rapid, practical and sensitive spectofluorimetric method was developed for the determination of trace amount of heparin (Hep). Under the Optimum conditions, we studied the interaction between NFLX-Ce$^{3+}$-Hep complex by using absorption and fluorescence spectra. It was observed that Hep remarkably enhance the fluorescence intensity of the NFLX-Ce$^{3+}$ complex at ${\lambda}$= 356 nm in the buffer solution of pH = 7.60 and the enhancement effect is shown to relate with the concentration of Hep. The linear range and detection limit for the determination of Hep was obtained. By the Rosenthal graphic method, the association constant (K) and binding numbers (N) of Hep with probe were investigated. This method is relatively free of interference from coexisting substances and successfully applied for the determination of heparin in heparin sodium injection samples. A suitable mechanism of fluorescence enhancement between NFLX-Ce$^{3+}$ and the NFLX-Ce$^{3+}$-Hep systems were proposed and discussed.

Rapid Determination of Volatile Organic Compounds in Human Whole Blood Using Static Headspace Sampling with Gas Chromatography and Mass Spectrometry

  • Lee, Ji-Young;Kim, Seungki;Lee, Jong-Tae;Choi, Jong-Ho;Lee, Jeongae;Pyo, Heesoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권12호
    • /
    • pp.3963-3970
    • /
    • 2012
  • Headspace (HS) and headspace solid-phase microextraction (HS-SPME) were studied for extracting volatile organic compounds (VOCs) from whole blood, with chemical and instrumental variables being optimized for maximum sensitivity: incubation at $60^{\circ}C$, equilibration for 30 min, pH 11, and 2 mL injection volume. Both techniques provided accurate analyses, with detection limits of 0.05-0.1 ng $mL^{-1}$ and 0.05-0.5 ng $mL^{-1}$. HS showed better sensitivity, reproducibility, and analysis times than HS-SPME. Overall levels of chloroform in whole blood were found to be 0.05-5.84 ng $mL^{-1}$; detected levels of benzene were 0.05-2.20 ng $mL^{-1}$.

항-보호항원 항체의 역가 측정을 위한 효소면역측정법 밸리데이션 (ELISA Validation for anti-PA Antibody Titer Measurements)

  • 김유진
    • 한국군사과학기술학회지
    • /
    • 제13권3호
    • /
    • pp.478-485
    • /
    • 2010
  • The vaccine is biological pretreatment that improves immunity to a particular disease. We can get immunity from producing antibody with injection antigen which has ability to defense against the disease. The ELISA is the most widely used method to measure antibody titer. We have developed and performed validation of ELISA according to the guideline of KFDA and ICH. In this paper, we have verified ELISA method is an excellent method to measure the titer of anti-PA antibody. We have constructed recombinant protective antigen among anthrax toxins and used as antigen of ELISA. In this validation, we have evaluated precision (repeatability, interlaboratory precision), specificity, linearity(range) and LOD, which are validation articles suggested by guideline. Inter-person precision was replaced with inter-laboratory precision. From the results, we have confirmed high precision in all experiments with CV under 20%.

스페이서에 Metal flange가 있는 GIS에서의 UHF PD 측정 기술 연구 (A study on the UHF PD measuring technique for GIS with a metal flange around insulating spacer)

  • 강원종;이창준;강윤식;박종배;이희철;박종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1638-1640
    • /
    • 2003
  • In the recent years, UHF PD measuring technique for detecting partial discharges was proved the effective method for Gas Insulated Switchgear (GIS). However, in case of GIS with a metal flange around insulating spacer, UHF PD measurement using typical external UHF PD sensor is difficult. In this paper, a novel hole-type UHF PD sensor based on Archimedean spiral antenna theory has been proposed and realized. All spacers with metal flange have small hole in order to inject epoxy. Using the novel hole-type UHF PD sensor, it makes detection possible to PD signal that are emitted through the epoxy injection hole. Additionally, the measuring characteristic of UHF PD signals from several artificial defects in GIS and the novel ${\Phi}$-f-q pattern analysis technology are discussed.

  • PDF

흰쥐에서 피리미딘 계열 항감염성 약물의 체내동태 (Pharmacokinetics of Antiviral Pyrimidine Analogs in Rats)

  • 한규원;정낙신;김길수
    • Journal of Pharmaceutical Investigation
    • /
    • 제30권2호
    • /
    • pp.113-118
    • /
    • 2000
  • In order to assay the efficacy of newly synthesized antiviral compounds, pyrimidine analogs, pharmacokinetics of those were established as compared with already marketed zidovudine. Zidovudine (15, 20, 25 and 35 mg/kg), LJ142 (18.52 mg/kg) and LJ143 (15, 18.52 and 30 mg/kg) were administered orally and intravenously in rats, blood samples were collected post-injection(i.e., for 360 min) at appropriate time intervals. Those were analyzed by HPLC with UV detection at 265 nm. Pharmacokinetic parameters $(C_{max},\;T_{1/2},\;MRT,\;AUC,\;AUMC,\;Vd_{SS},\;Cl_t)$ were calculated. AUCs of zidovudine and LJ143 following I.V. dosing of $15{\sim}25\;mg/kg\;and\;15{\sim}18.18\;mg/kg$ were dose-independent. However, AUCs of zidovudine and LJ43 following I.V. dosing of $25{\sim}35\;mg/kg\;and\;18.18{\sim}30\;mg/kg$ were dose-dependent. The relative bioavailability of zidovudine, LJ142 and LJ143 following oral administration were 61.94, 46.44 and 78.24%, respectively.

  • PDF

다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I) (Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I))

  • 안재현;김용모;김세원
    • 한국연소학회지
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

토마토 종류에 따른 카로티노이드 함량 비교와 다중분석법 개발 (Method Development and Analysis of Carotenoid Compositions in Various Tomatoes)

  • 김한결;천진혁;김선주
    • 한국환경농학회지
    • /
    • 제34권3호
    • /
    • pp.196-203
    • /
    • 2015
  • BACKGROUND: Purpose of this research is HPLC analysis method development of lycopene in tomato. And then, three components of carotenoid in four kinds of tomatoes (general tomato, cherry tomato, red and orange date tomato) were compared with each other. METHODS AND RESULTS: Lycopene in tomato was extracted with hexane likes other carotenoid components using 500 mg of dried powder sample. HPLC analysis conditions were column temperature ($40^{\circ}C$), detection wavelength (454 nm), flow rate (1.0 mL/min) and injection volume ($20.0{\mu}L$). Lycopene was analyzed by the gradient elution ($60{\rightarrow}100%$) of the mobile phase solvents A[water: methanol=25: 75 (v/v)] and B[ethyl acetate]. CONCLUSION: Three components of carotenoids (lutein, ${\beta}$-carotene, lycopene) were observed in tomatoes. The total carotenoid contents was the highest in red date tomato (662.0 mg/kg dry wt.) and the lowest in orange date tomato (111.3 mg/kg dry wt.). Lycopene contents in tomatoes was the highest percentage (93%) among all the carotenoids.

Pharmacokinetics of Dehydroevodiamine Following Intravenous Administration in Rats

  • Kim, Seong-Yun;Moon, Chan-Soo;Choi, Yun-Sik;Lee, Sang-Bok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제8권1호
    • /
    • pp.65-67
    • /
    • 2004
  • Dehydroevodiamine (DHED) is one of the bioactive components of the Chinese herbal medicine Wu-chu-yu-tang that has been shown to produce various pharmacological effects. In the present study, we investigated the pharmacokinetics of DHED after intravenous administration of two doses (2.5 and 5 mg/kg) in anesthetized rats. The plasma concentration of DHED was measured by reverse-phase high-performance liquid chromatography with UV detection. The mean area under the curve of the time-concentration profile was $21.9\;and\;53.9\;{\mu}g{\cdot}min/ml$ after the 2.5- and 5-mg/kg doses, respectively, and the volume of distribution was 1584.9 and 1580.6 ml following 2.5- and 5-mg/kg doses, respectively. Plasma concentration profiles versus time were compatible with a two-compartment model and first-order kinetics. The terminal elimination half-life was $91.8{\pm}16.6\;min$ and $78.7{\pm}11.9\;min$ in the dose of 2.5 and 5 mg/kg, respectively. This is the first report to study the pharmacokinetics of DHED in animals.