• Title/Summary/Keyword: injection detection

Search Result 485, Processing Time 0.026 seconds

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

The study on sterilization effect of disinfectants and detection of bacteria (상용 소독제의 살균력 및 균 소장 상태 검정)

  • Song, Gyu-Nam
    • The Korean Nurse
    • /
    • v.37 no.2
    • /
    • pp.77-86
    • /
    • 1998
  • Yeung Nam University Medical Center, Department Of Central medical Supply Background: The adverse effect of intravenous therapy combined with various complications. Because sterilization technique and appropriate nursing care can prevent various complications, it is important to use appropriate sponge in intravenous therapy. The purpose of study was to identy sterilization effect and detection of bacteria and to provide basic data for use of appropriate disinfectants. Methods: From May 15 1995 to Aug. 3. 1995, disinfectants that were used in Yeung Nam University Medical Center were tested by bacteria culture. To test sterilization effect of disinfectants of intravenous injection sites after disinfection, 10 subjects were used and were tested by bacteria culture for the study. Results: 1) By sterilization effect of disinfectants, bacteria were increased from 103 to 10 from 48 hours in both 2% Zephanon and 2% zephanon that was sterilized by steam, from 10 to 10 from 72 hours and 10 from 48 hours in 70% lsoprophyl alchol. Also, bacterias were detected in 70% lsoprophyl alchol on 48 hours. 2) By stenlization effect of sponge that were used in nursing unit, bacterias were detected in 2% Zephanon on 2 hours, 70% lsoprophyl alchol on 2 hours, 70% lsoprophyl alchol on 8 hours and 70% lsoprophyl alchol on 48 hours. 3) By sterilization effect and detection of bacteria of intravenous site after disinfection, bacterias were detected in 10 of 10 control groups, 8 of 10 sites that were disinfected by steam sterilized 2% zephanon sponge, 6 of 10 sites that were disinfected by 70% lsoprophyl alchol and 4 of 10 sites that were disinfected by 10% Batadine. Conclusions : it is conclued that 70% lsoprophyl alchol is appropriate for intravenous therapy and 10% Betadine is appropriate in ward that were polluted the air and in immunodeficient patients.

  • PDF

Analysis of the Connectivity of Monitoring Nodes and the Coverage of Normal Nodes for Behavior-based Attack Detection in Wireless Sensor Networks (무선 센서 네트워크에서 행위 기반 공격 탐지를 위한 감시 노드의 연결성과 일반 노드의 커버리지 분석)

  • Chong, Kyun-Rak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.12
    • /
    • pp.27-34
    • /
    • 2013
  • In wireless sensor networks, sensors need to communicate with each other to send their sensing data to the administration node and so they are susceptible to many attacks like garbage packet injection that cannot be prevented by using traditional cryptographic approaches. A behavior-based detection is used to defend against such attacks in which some specialized monitoring nodes overhear the communications of their neighbors to detect bad packets. As monitoring nodes use more energy, it is desirable to use the minimal number of monitoring nodes to cover the whole or maximal part of the network. The monitoring nodes can either be selected among the deployed normal nodes or differ in type from normal nodes. In this study, we have developed an algorithm for selecting the predefined number of monitoring nodes needed to cover the maximum number of normal nodes when the different types of normal nodes and monitoring nodes are deployed. We also have investigated experimentally how the number of monitoring nodes and their transmission range affect the connection ratio of the monitoring nodes and the coverage of the normal nodes.

Detection of Source Code Security Vulnerabilities Using code2vec Model (code2vec 모델을 활용한 소스 코드 보안 취약점 탐지)

  • Yang, Joon Hyuk;Mo, Ji Hwan;Hong, Sung Moon;Doh, Kyung-Goo
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2020
  • Traditional methods of detecting security vulnerabilities in source-code require a lot of time and effort. If there is good data, the issue could be solved by using the data with machine learning. Thus, this paper proposes a source-code vulnerability detection method based on machine learning. Our method employs the code2vec model that has been used to propose the names of methods, and uses as a data set, Juliet Test Suite that is a collection of common security vulnerabilities. The evaluation shows that our method has high precision of 97.3% and recall rates of 98.6%. And the result of detecting vulnerabilities in open source project shows hopeful potential. In addition, it is expected that further progress can be made through studies covering with vulnerabilities and languages not addressed here.

A Key Redistribution Method for Enhancing Energy Efficiency in Dynamic Filtering based Sensor Networks (동적 여과 기법 기반 센서 네트워크의 에너지 효율을 높이기 위한 키 재분배 결정 방법)

  • Sun, Chung-Il;Cho, Tae-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.1
    • /
    • pp.125-131
    • /
    • 2010
  • In wireless sensor networks application, sensor nodes are randomly deployed in wide and opened environment typically. Since sensor networks have these features, it is vulnerable to physical attacks in which an adversary can capture deployed nodes and use them to inject a fabricated report into the network. This threats of network security deplete the limited energy resource of the entire network using injected fabricated reports. A dynamic en-route filtering scheme is proposed to detect and drop the injected fabricated report. In this scheme, node executes the key redistribution to increases the detection power. It is very important to decide the authentication key redistribution because a frequent key redistribution can cause the much energy consumption of nodes. In this paper, we propose a key redistribution determining method to enhance the energy efficiency and maintain the detection power of network. Each node decides the authentication key redistribution using a fuzzy system in a definite period. The proposed method can provide early detection of fabricated reports, which results in energy-efficiency against the massive fabricated report injection attacks.

Studies on the Determination of Heavy Metal Ions by Flow Injection, the Photochemical Characterization and Polymerization of Eight-Coordinated Complex(Part I): Spectrophotometric Determination of Uranium and Thorium Ions by Flow Injection Analysis using Chrome Azurol S in the Presence of Surfactant (금속이온의 흐름주입법에 의한 정량, 8-배위착물의 광학적 특성 및 중합체에 관한 연구(제1보): 계면활성제 존재하에서 Chrome Azurol S를 사용하여 우라늄 및 토륨이온의 흐름 주입법에 의한 분광광도 정량)

  • Chang, Choo-Hwan;Kang, Sam-Woo;Son, Byung-Chan;Cho, Kwang-Hee
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • Spectrophotometric determination of U(VI) and Th(IV) by Flow injection method is described. Chrome Azurol S forms water soluble complexes with U(VI) and Th(IV) in the presence of cethyltrimethylammonium bromide. The maximum adsorption of U(VI) and Th(IV) complexes are at 600nm with molar absorptivity of $2.3{\times}10^5Lmol^{-1}cm^{-1}$ and 611nm with molar absorptivity of $3.8{\times}10^5Lmol^{-1}cm^{-1}$ in acetate buffer medium having pH 5.0 and 5.5. The calibration curves of U(VI) and Th(IV) are linear over the range of 0.1~0.8ppm and the correlation coefficients are ca. 0.9960 and 0.9930 respectively. The detection limits(S/N) are 20ppb for U(VI) and 15ppb for Th(IV). The relative standard deviation are ${\pm}1.8%$ for U(VI) and ${\pm}2.1%$ for Th(IV). The sample throughput was ca. $50hr^{-1}$.

  • PDF

Applicability of the Multi-Channel Surface-soil CO2-concentration Monitoring (SCM) System as a Surface Soil CO2 Monitoring Tool (다채널 지표토양 CO2 농도 모니터링(SCM) 시스템 개발 및 적용성 평가 연구)

  • Sung, Ki-Sung;Yu, Soonyoung;Choi, Byoung-Young;Park, Jinyoung;Han, Raehee;Kim, Jeong-Chan;Park, Kwon Gyu;Chae, Gitak
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.1
    • /
    • pp.41-55
    • /
    • 2015
  • Monitoring of $CO_2$ release through the ground surface is essential to confirm the safety of carbon storage projects. We conducted a feasibility study of the multi-channel surface-soil $CO_2$-concentration monitoring (SCM) system as a soil $CO_2$ monitoring tool with a small scale injection test. The background concentrations showed the distinct diurnal variation. The negative relation of $CO_2$ with temperature and the low $CO_2$ concentrations during the day imply that surface-soil $CO_2$ depends on photosynthesis and respiration. After 4.2 kg of $CO_2$ injection (1 m depth for 29 minutes), surface-soil $CO_2$ concentrations increased in the all five chambers, which were located less than 2.8 m of distance from each other. The $CO_2$ concentrations seem to be recovered to the background around 4 hours after the injection ended. To determine the leakage, the data from Chamber 2 and 5 with low increase rates were used for statistical analyses. Coefficient of variation for 30 minutes ($CV_{30min}$.) is efficient to determine a leakage signal, with reflecting the fast change in $CO_2$ concentrations. Consequently, SCM and $CV_{30min}$ could be applied for an efficient monitoring tool to detect $CO_2$ release through the ground surface. Also, this study provides ideas for establishing action steps after leakage detection.

A Study on the Reinforcement and Environmental Impact of LW Injection (LW주입에 의한 지반보강 및 환경영향성에 관한 연구)

  • Chun, Byungsik;Do, Jongnam;Sung, Hwadon;Lim, Jooheon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.121-131
    • /
    • 2006
  • This study is performed to examine the ground reinforcement effect and the environmental impact of LW injection, which is widely used during the excavation of high-rise apartment buildings. In addition, it proved that by conducting field exploration and laboratory test the engineering ground reinforcement effect of LW injection in the ground has low coefficient of permeability. The environmentally friendly aspect was evaluated through an assessment of environmental impact. The results of laboratory test shows that LW coagulating material with SC type soil structure has significant improvement of uniaxial compressive strength, increasing by three times and the shear strength increasing by twice, coefficient of permeability decreasing six to seven times. And the result of environmental impact tests show that from 6 hour after where the pH increases until 7.96 to initially it diminished, it started and to 80 hour after it recovered a pH 7.25 initially with 7.30. The chemical composition analysis test result that unpolluted water and polluted water hydrogen ion concentration (pH) show that the unpolluted water pH 7.36, polluted water pH 7.85, which is inside the Ministry of Environment standard of drinking water (the pH 5.8~8.5). The assessment of environmental impact and chemical analysis test also demonstrate that the LW coagulating material is environmentally friendly. In the $Cr^{6+}$ and the salinity detection test, it was proven that the salinity is slight and the $Cr^{6+}$ is not detected.

  • PDF

Combustion Diagnostics Method Using Diode Laser Absorption Spectroscopy (다이오드 레이저를 이용한 연소진단기법)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Kim, Hyuck-Joo;Han, Jae-Won
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.75-83
    • /
    • 2003
  • Diode laser absorption system is advantageous of their non-invasive nature, fast response time, high sensitivity and real-time measurement capability. Furthermore, recent advances in room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system are now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and develope new gas sensing system. It experimentally found out that the wavelength, power characteristics as a function of injection current and temperature. In addition to direct absorption and wavelength modulation spectroscopy have been demonstrated in these experiments and have a bright prospect to this diode laser system.

  • PDF