• Title/Summary/Keyword: injection detection

Search Result 485, Processing Time 0.031 seconds

Effects of Daihwangmudan-tang on Urate Lowering and Detection of Relevant Genes (대황목단탕(大黃牧丹湯)의 요산지표 개선효과와 관련 유전자 탐색)

  • Kim Joong-Bae;Chi Gyoo-Yong;Eom Hyun-Sup
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1534-1540
    • /
    • 2005
  • In order to testify the urate lowering effects of Daihwangmudan-tang(DMT), ICR mice were injected monosodium urate into the abdominal cavity and then DMT was administered on 2 and 4 days after Injection. Uric acid and triglyceride were measured as hematological indices of gout, and some genes related with this change were identified by ACP based GeneFishing PCR method and direct sequencing. From this experiment, DMT highly decreased the blood levels of uric acid and significantly suppressed and lowered the acute increment of triglyceride level. There were 11 differentially expressed genes(DEG) having relations with positive actions of DMT, and 4 major genes in the middle of DEGs were sequenced; Mfap 2, jagged 2, Hsd17b7, DkkI-1, These genes were supposed that several mechanisms through interleukin 1 and T-cell anergy, LDL cholesterol metabolism, wnt pathway would be related with the anti-inflammation effect against gout.

Automatic detection of the optimal ejecting direction based on a discrete Gauss map

  • Inui, Masatomo;Kamei, Hidekazu;Umezu, Nobuyuki
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.48-54
    • /
    • 2014
  • In this paper, the authors propose a system for assisting mold designers of plastic parts. With a CAD model of a part, the system automatically determines the optimal ejecting direction of the part with minimum undercuts. Since plastic parts are generally very thin, many rib features are placed on the inner side of the part to give sufficient structural strength. Our system extracts the rib features from the CAD model of the part, and determines the possible ejecting directions based on the geometric properties of the features. The system then selects the optimal direction with minimum undercuts. Possible ejecting directions are represented as discrete points on a Gauss map. Our new point distribution method for the Gauss map is based on the concept of the architectural geodesic dome. A hierarchical structure is also introduced in the point distribution, with a higher level "rough" Gauss map with rather sparse point distribution and another lower level "fine" Gauss map with much denser point distribution. A system is implemented and computational experiments are performed. Our system requires less than 10 seconds to determine the optimal ejecting direction of a CAD model with more than 1 million polygons.

A Drug Sensitivity Test for Shortening of Detection Time (항균성물질(抗菌性物質) 감수성시험(感受性試驗)의 시간단축(時間短縮)과 임상적응용(臨床的應用))

  • Kim, Kyo-Joon;Hu, Min-Do;Lee, Myung-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.23 no.1
    • /
    • pp.123-128
    • /
    • 1983
  • This study was conducted to evaluate the modified drug sensitivity test for the shortening of detection time and clinical application. The results obtained were summarized as follows. 1. Inhibitory zone in 6 strains of Staphylococcus and Escherichia coli tested to sensitivity teat were reached at 100% between 2 and 6 hours. 2. The sensitivity test of Staphylococcus A, B and E. coli No. 2, No. 3 to antibacterial ointment drugs were strong positive(+++), but Staphylococcus A. A. and E. coli No. 1 were mild resistant(+). 3. The sensitivity test of Staphylococcus A. B and E. coli No. 2, No. 3 to antibacterial injection drugs in 6 hours after treatment were strong positive(+++), and Staphylococcus A. A. and E. coli No. 1 were moderate positive(++). 4. This modified method was detected 86% degree of sensitive between 7 to 12 hours after treatment. 5. We think this modified method was more practical compare to other methods.

  • PDF

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.

Initial Rotor Position Detection of Single-phase Permanent Magnet Synchronous Motor using Offset Voltage (옵셋 전압을 이용한 단상 영구자석 동기 전동기의 초기 회전자 위치 검출)

  • Hwang, Seon-Hwan;Seo, Sung-Woo;Jung, Tae-Uk
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.622-627
    • /
    • 2019
  • This paper propose an initial rotor position detection method for sensorless operation of a single-phase permanent magnet synchronous motor(SP-PMSM) with asymmetric air-gap. In general, the sensorless control based on back-emf estimation is difficult to estimate the back-emf at the zero and low speed regions. For this reason, an open loop start-up technique is indispensable, and it is also necessary to detect the initial position of the rotor in order to rotate in a certain direction. In this paper, we propose a method to detect rotor polarity by adding offset voltage to high frequency voltage signal based on the magnetic characteristics of SP-PMSM. The validity and usefulness of the proposed algorithm are verified through several experimental results.

Rubber O-ring defect detection using adaptive binarization, Convex Hull preprocessing, and convolutional neural network learning method (적응형 이진화와 Convex Hull 전처리 및 합성곱 신경망 학습 방법을 적용한 고무 오링 불량 판별)

  • Seong, Eun-San;Kim, Hyun-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.623-625
    • /
    • 2021
  • Rubber o-rings are produced by conventional injection molding methods. In this case, products that are not normally molded are determined to be defective. However, if images acquired during image-based reading are read as original, there is a problem of poor accuracy. We have thus learned from convolutional neural networks using adaptive binarization and Convex Hull algorithms by extracting only rubber oring parts from the original images through pre-processing. During the test process, it was confirmed that the defect detection performance of the learning method applied pre-processing was better than the standard suggested.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Determination of Some Inorganic Anions in Saline Water by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 소금물중의 무기음이온들의 분리정량)

  • Han, Sun Ho;Park, Yang Soon;Park, Soon Dal;Joe, Kih Soo;Eom, Tae Yoon
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 1999
  • A stepwise gradient elution with two wavelengths detection was performed for the separation and determination of some anions in saline water. The eight anions such as iodate, bromate, nitrite, bromide, nitrate, chromate, iodide and thiocyanate were successfully separated using AS-7 column and sodium chloride/sodium phosphate buffer solution as an eluant within 40 min. The separation behaviors of anions were studied at various sodium chloride concentrations. The peak shapes of anions of bromate, nitrite, bromide and nitrate gradually broadened as the concentration of sodium chloride increased until 1.0 M in the sample solutions. However, no effect was observed in the peak shapes of chromate, iodide and thiocynate. A good linearity was obtained at the range of ppm(mg/L). The detection limit was proved to be $10-720{\mu}g/L$ for the eight anions with $50{\mu}L$ injection volume. This method was applied to the determination of $Br^-$, ${NO_3}^-$ and $I^-$ in sea water.

  • PDF

Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode (Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템)

  • Yi In-Je;Kang Chi-Jung;Kim Yong-Sang;Kim Ju-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.