• Title/Summary/Keyword: injection detection

Search Result 485, Processing Time 0.025 seconds

Potentimetric Biosensor for Detection of L-Malate and D-Isocitrate Employing ${CO_{3}}^2-$ -Selective Electrode and Enzyme Immobilization in Flow Injection Analysis

  • Kwun, In-Sook;Kim, Meera
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.1
    • /
    • pp.36-42
    • /
    • 1998
  • Ion-selective eleltrodes(ISEs) are simple electrodechemical devices for the direct measurement of ions in the samples. A novel potentiometric biosensor for the determination of L-Malate or D-isocitrate has been developed by using CO2-3 -ISE-FIA system was composed of a pump, an injector, a malic enzyme or isocitric dehydrogenase enzyme reactor, a CO2-3 -ISE, a pH/mV meter, and an integrater. The various factors, such as buffer capacity types of plstericizer and polymer, were optimized for the CO2-3 selectivity. In this novel CO2-3 --ISE-FIA system, the potential difference due to the amount of CO2-3 produced from each enzyme reaction was proportional to the amount of L-malate or D-isocitrate.

  • PDF

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF

Implementation of Differential Absorption LIDAR (DIAL) for Molecular Iodine Measurements Using Injection-Seeded Laser

  • Choi, Sungchul;Baik, Sunghoon;Park, Seungkyu;Park, Nakgyu;Kim, Dukhyeon
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.325-330
    • /
    • 2012
  • Differential absorption LIDAR (DIAL) is frequently used for atmospheric gas monitoring to detect impurities such as nitrogen dioxide, sulfur dioxide, iodine, and ozone. However, large differences in the on- and off-line laser wavelengths can cause serious errors owing to differential aerosol scattering. To resolve this problem, we have developed a new DIAL system for iodine vapor measurements in particular. The suggested DIAL system uses only one laser under seeded and unseeded conditions. To check the detection-sensitivity and error effects, we compared the results from a system using two seeded lasers with those from a system using a seeded and an unseeded laser. We demonstrate that the iodine concentration sensitivity of our system is improved in comparison to the conventional two seeded or two unseeded laser combinations.

Changes in the gas chromatographic sensitivity with its analytical setting: Comparison of TDU and loop-injection system for the analysis of sulfur compounds (GC 분석 시스템의 설정과 그에 따른 감도의 차이: 열탈착 방식 대비 루프주입방식에 의한 황성분의 분석)

  • Kim, Ki-Hyun;Choi, Y.J.;Kim, S.C.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.66-73
    • /
    • 2005
  • In this study, we investigated the gas chromatography (GC) and pulsed flame photometric detection (PFPD) system for the analysis of four major reduced S compounds including hydrogen sulfide ($H_2S$); methyl mercaptan ($CH_3SH$); dimethyl sulfide (DMS); and dimethyl disulfide (DMDS) contained in environmental samples. To analyze these compounds in high concentration range (above ppb level), we developed a high mode analytical setting with the loop-injection system. By contrast, we also established a low mode setting for the analysis of low concentration samples (ppt-level samples from ambient air) by the combination with thermal desorption unit (TDU). Comparative analysis of both settings revealed that relative detection properties of four S compounds are systematic enough. The results of high mode analysis indicated that the patterns were systematic among S compounds: $H_2S$ exhibited the lowest sensitivity, while DMDS showed the strongest one. The results were also compared in terms of sensitivity reductions for all compounds by dividing slope ratios between low and high mode system. Although low mode system exhibited significant reductions on the order of a few tens times, their detection characteristics were highly consistent as it was shown in the high mode setting. To learn more about absolute and relative relations between two different modes of S analysis, future studies may have to be directed to cover more complicated nature of GC/PFPD performance.

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid (계통연계 분산전원의 새로운 단독운전 판별기법)

  • Bae, Byung-Yeol;Lee, Doo-Young;Ko, Jong-Sun;Choi, Nam-Sub;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

A Welding Defect Inspection using an Ultrasound Excited Thermography (초음파 서모그라피를 이용한 용접 결함 검사)

  • Jo Jae-Wan;Jeong Jin-Man;Choi Yeong-Su;Jeong Seung-Ho;Jeong Hyeon-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.148-150
    • /
    • 2006
  • In this paper, the applicability of an UET(ultrasound excited thermography) for a defect detection of the welded receptacle is described. An UET(ultrasound excited thermography) is a defect-selective and fast imaging tool for damage detection. A high power ultrasound-excited vibration energy with pulse durations of 280ms is injected into the outer surface of the welded receptacle made of Al material. An ultrasound vibration energy sent into the welded receptacle propagate inside the sample until they are converted into the heat in the vicinity of the defect. The injection of the ultrasound excited vibration energy results in heat generation so that the defect is turned into a local thermal wave transmitter. Its local heat emission is monitored by the thermal infrared camera. And they are processed by the image recording system. Measurement was performed on aluminum receptacle welded by using Nd:YAG laser. The observed thermal image revealed two area of defects along the welded seam.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

Development of System For Cell Fusion Detection (세포 전기 융합 감지 장치에 관한 연구)

  • Kwon, Ki-Jin;Kim, Min-Soo;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

Fabrication of Microcantilever-based Biosensor Using the Surface Micromachining Technique (표면 미세 가공기술을 이용한 마이크로 캔틸레버의 제작과 바이오센서로의 응용)

  • Yoo Kyung-Ah;Joung Seung-Ryong;Kang C. J.;Kim Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.11-15
    • /
    • 2006
  • We propose an optical and an electrical detection methods for detecting various bio-molecules effectively with microcantilevers. The microcantilevers were fabricated employing surface micromachining technique that has attractive advantages in terms of cost efficiency, simplicity and ability of fabricating in array. The fluid cell system for injection of bio-molecular solution is fabricated using polydimethylsiloxane (PDMS) and a fused silica glass. The microcantilever is deflected with respect to the difference of the surface stress caused by the formation of self-assembled bio-molecules on the gold coated side of the microcantilever. It detected cystamine dihydrochloride and glutaraldehyde molecules and analyzed individual concentrations of the cystamine dihydrochloride solution. We confirm that the deflections of bending-up or bending-down are occurred by the bio-molecule adsorption and microcantilever can be widely used to a ${\mu}-TAS$ and a lab-on-a-chip for a potential detection of various bio-molecules.