• 제목/요약/키워드: injection

검색결과 15,372건 처리시간 0.039초

Reevaluation of the Necessity of Iron Injection to Newborn Piglets

  • Yu, I.T.;Lin, J.;Wu, J.F.;Yen, H.T.;Lee, S.L.;Yang, T.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권1호
    • /
    • pp.79-83
    • /
    • 2002
  • The growth and immune responses to endotoxin lipopolysaccharide (LPS) challenge ( $20{\mu}g/kg$) of piglets with and without a iron dextran injection (Fe, 200 mg/head) two days after birth are compared. Sixty-four newborn piglets from eight litters were allocated randomly to one of four treatments. The control received no iron dextran and only saline (Sal) injection on the second and fifteenth day after birth (Sal-Sal). The remaining three groups received Fe-Sal, Sal-LPS, Fe-LPS treatments respectively. On fifteen days of age, blood samples of piglets were taken at 0 h, 1 h, 2 h and 4 d after saline or LPS injection to determine immune functions and blood characteristics. The trial terminated when the pig reached 56 days and the average daily gain of piglets was then measured. Daily gain, serum immunoglobulin G (IgG) concentration and red blood cell counts did not vary significantly among the four groups at any measuring times. Serum tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) concentration increased sharply 1 h after LPS injection. However, iron injection did not change TNF-${\alpha}$ concentration responds to LPS injection. White blood cell counts of two LPS injection groups were significantly lowered 1 h following the injection. In contrast, serum lactoferrin concentration had increased significantly 1 and 2 h postinjection. Furthermore, iron injection produced no further effects on these two criteria. Iron injection increased the hemoglobin (Hb) concentration of piglets at any measuring time, and LPS injection lowered Hb concentration. In conclusion, a 200 mg/head of iron dextran injection on the second day after birth increased Hb concentration, had no detrimental effect on the immune responses and growth of piglets. Moreover, if creep feed (175 mg Fe/kg feed) is provided from d 7 after birth, the Fe-injection does not contribute to overall performance of piglets and may not be a necessity in practice.

디이젤 기관용 다공연료 분사 밸브의 분사율 측정 (On Rate of Multi-Hole Injector for Diesel Engine)

  • 정달순;안수길;권기린
    • 수산해양기술연구
    • /
    • 제22권1호
    • /
    • pp.41-48
    • /
    • 1986
  • Ifis recommended that the injection rate should be accurate and reliable in the input data of the performance simulation in diesel engine. Matsuoka Sin improved W. Bosch's injection ratio measurement system. Matsuoka Sin reduced length of the test pipe and set the orifice. However, it was not measured accurately to measure the injection ratio due to reflection wave. In the present thesis, the improved measurement system with combination of the conventional W. Bosch type injection ratio measurement system and Matsuoka Sin type corrected W. Bosch type was practically made. The location of orifice and throttle valve was modified and set one more back pressure valve in order to reduce the effect of reflection wave. The results according to injection condition of multi-hole nozzle are following: 1. Measurement error of injection ratio measurement system in this thesis was $\pm$ 1 %, therefore, its reliability was good. 2. The form of injetion ratio is changed from trapezoidal shape to triangle shape with increase of revolution per minute when injection amount is constant. 3. In the case of constant rpm, the initial injection ratio is almost constant regardless of the amount, meanwhile the injection period becomes longer with increase of the amount. 4. The injection pressure of nozzle isn't largely influenced with injection ratio in the case of constant injection amount and rpm, otherwise the initial injection amount is increased by 3-4% when the injection pressure is low. 5. The injection ratio isn't nearly influenced with back pressure.

  • PDF

수치모델을 활용한 지하수 인공함양 대상지의 적정 주입량 및 주입효율 예비 평가 (Preliminary Evaluation of the Optimal Injection Rate and Injection Efficiency of Groundwater Artificial Recharge Site Using Numerical Model)

  • 차장환;김규범;이재영
    • 지질공학
    • /
    • 제31권1호
    • /
    • pp.19-30
    • /
    • 2021
  • 본연구에서는 가뭄이 빈번히 발생하는 지류 상류 지역에서 농번기에 부족한 물을 확보하기 위하여 평상시 잉여의 물을 지하 대수층에 주입하는 인공함양 방식을 설계함에 앞서 적정 주입량 및 주입효율을 수치모델을 활용하여 평가하고자 하였다. 인공함양 수치모델 대상지역은 홍성군 갈산면 운곡리 일대를 대상으로 하였으며 다양한 공당 주입량 조건과 대수층의 수리적 특성을 고려하여 모델링을 수행한 결과, 연구지역의 공당 적정주입량은 50.0 ㎥/day/공로 평가되었으며 주입효율은 총 주입용량 대비 33.2~81.2%로 예측되었다. 특히, 주입효율은 주입시간이 짧을수록 비선형으로 증가하는 양상을 보였으며 잔류 저류용량은 총 주입용량이 많을수록 증가하여 물부족 시 사용 가능량이 많아지므로 보다 유리할 것으로 보였다. 향후 보다 정확한 함양효율 평가를 위해 현장 실증시험 결과를 활용하여 모델을 검증하고 이를 통해 주입 및 취수에 대한 적정 시나리오를 구축한다면 보다 효율적인 인공함양 시스템의 운영이 가능할 것이다.

디젤기관용 분사밸브 형상에 따른 분사특성 (Injection Characteristics with Valve Geometries for a Diesel Engine)

  • 김성윤;오승우;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.745-752
    • /
    • 2003
  • Injection technology is one of the important technologies in a diesel engine. Many studies have done on the injection system. In this study, the fuel chamber geometry, the orifice ratio and the needle lift of the injection valve of a diesel engine for generating electricity are varied and tested. The injection pressure, duration and spray shapes are produced with pressure transducer, needle lift sensor and highspeed camera. The result shows that the nozzle hole size has influence on the rail pressure and injection duration sensuously.

턱관절장애 치료를 위한 주사요법 (Injection therapy for management of temporomandibullar joint disorders)

  • 조상훈
    • 대한치과의사협회지
    • /
    • 제57권4호
    • /
    • pp.222-232
    • /
    • 2019
  • Injection therapy can be used to treat the refractory and chronic pain situations that are not well responded to conventional therapy in TMD-patients. The target of injection is the intra-articular- and peri-articular tissue of joint and adjacent tissue like muscle. For the success of injectional therapy, selection of injection solution and technique is essential, so discussion will be done about that and one of the promising techniques of intra-articular injection, US-guided TMJ Intrar-articular injection, is also discussed.

  • PDF

사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구 (A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding)

  • 이준한;김종선
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.

코어백 방식을 이용한 동시사출 성형 공정 최적화 연구 (Optimization of Multi-component Injection Molding Process Based on Core-back System)

  • 최동조;박홍석
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.67-74
    • /
    • 2009
  • Injection molding have been used for manufacturing various fields of automotive interior trims for years. The demands on the injection molding technique are grown with the further development of the automobile technique and the design presentations for cost reduction and environment-friendly. This paper shows that multi-component injection conditions are different from general injection, also shows how to optimize part design and mold design and how to manufacturing through the efficient use of multi-component injection in development process using core back system. To fulfill this purpose, all influential process parameters related to the quality of automobile parts were analyzed in terms of the correlation between them. Base on that, a innovative process will be developed by injection engineers to implement it in practice.

대형 CNG기관의 직접분사화에 의한 희박한계확장 (A study on expansion of lean burn limit with direct injection of the heavy-duty CNG engine)

  • 박정일;정찬문;노기철;이종태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3282-3287
    • /
    • 2007
  • Lean combustion is one of the most promising method for increasing engine efficiency and reducing the exhaust emission from SI gas engines. Due to the possibility of partial burn and misfire, however, under lean burn operation, stable flame kernel formation and fast burn rate are needed to guarantee a successful subsequent combustion. Experiment data were obtained on a single-cylinder CNG fueled SI engine to investigate the effect of direct injection, spark timing and variation of injection timing. Experimental results show that lean burn limit is ${\lambda}$=1.3 with port injection, and expansion of lean burn limit ${\lambda}$=1.4 with direct injection method, due to increase of turbulence intensity in cylinder and stratified charge. Combustion duration in lean region is improved by using the variation of injection timing.

  • PDF

Flat TV Front Cover Gas 사출 금형에 대한 연구 (A Study on Gas-Assisted Plastic Injection Mould of Flat TV Front Cover)

  • 문영대
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.201-206
    • /
    • 2003
  • Plastic injection mould have two kinds of trouble, one is in mould another in injection parts. Most of defects of the former take the cause in a design like in structure and working, the later weld line, transforming, sink mark, burning, flow mark, scratching, shading, black hole and so on. Most of problems of the later is difficult for making a clear definitely the reason of defects because of complexible. The purpose of this paper is to improve the quality of plastic injection mould and parts with inquiring the counter plan and rouble of the part of Flat TV Front Cover by flow control method and gas- assisted injection moulding. For minimizing defects from injection moulding parts, this paper was investigated with using computer aided injection mold filling simulations. Based on these numerical results, I established guidelines mould design and injection processing condition. As a results I got the improve of quality, minimizing surface defects moulded parts and troubles in mould.

  • PDF

사출성형품의 웰드라인 강도에 관한 연구 (A Study on the Weld Line Strength in Injection Molded Part)

  • 모정혁;홍형식;류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.211-216
    • /
    • 2003
  • Weld line in injection molded part is one of the defect in injection molding process. Weld line deteriorates not only appearance quality but mechanical property. In this study weld line strength has been examined according to the injection operational conditions, materials and mold designs. PC and PP were used, and four different specimens were used in this experiment. Weld line strength decreased as injection temperature increases for PC. It was more dependent on mold temperature than injection temperature for PP Among the four different specimens, uneven thickness specimen showed the highest weld line strength.

  • PDF