• Title/Summary/Keyword: injecting technology

검색결과 202건 처리시간 0.022초

시판용 미생물탈취제를 이용한 하수 악취 내 황화수소 저감에 관한 실험적 연구 (Experimental Study on Hydrogen Sulfide Abatement in Sewage Odor Using Microbial Deodorants on the Market)

  • 박상진;권수열
    • 한국환경보건학회지
    • /
    • 제46권2호
    • /
    • pp.170-183
    • /
    • 2020
  • Objectives: This study was conducted to estimate a technology to reduce hydrogen sulfide (H2S) in sewage odor using microbial deodorant. Methods: After injecting five commercially available microbial deodorants into fresh sewage, the concentration of hydrogen sulfide over time was measured using the headspace method. H2S concentration in odor samples was measured using gas chromatograph/FPD. Calculated odor concentration and calculated odor intensity by H2S concentration remaining after treatment with microbial deodorant were evaluated theoretically. Results: The rate of H2S abatement by microbial deodorant differed depending on the experimental conditions and the type of deodorant, but it was found to range from 63 to 82%. Especially, two deodorants showed high H2S reduction rates of over 80% on average. However, based on the best deodorant, the theoretically calculated odor concentration by H2S after microbial deodorant treatment was 4,400 OUk, and the theoretical odor intensity was also rated at 4 degrees or higher. Conclusions: In conclusion, microbial deodorant is considered to have a relatively high effect on reducing H2S in sewage odor. However, even after treatment with microbial deodorant, calculated odor concentration and calculated odor intensity were relatively high. This is thought to be caused by other odorous substances besides H2S.

NASICON 고체 전해질을 사용한 SOx 가스 감지센서 (SOx Sensor Using NASICON Solid Electrolyte)

  • 최순돈;이광범
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.25-34
    • /
    • 1996
  • NASICON 전해질을 이용하여 대기환경 측정용의 SOx센서를 개발하였다. 다음 형태의 $Na_{2}SiO_{3}(Pt)$ 기준전극을 사용한 갈바니 셀을 조립하였다. Pt | $Na_{2}SiO_{3}$ | NASICON | $Na_{2}SO_{4}$ | Pt, $SO_{2}$, air $SO_{2}$ 와 NASICON의 반응을 피하기 위해 $Na_{2}SO_{4}(Pt)$를 지시전극으로 사용하였으며, $400{\sim}550^{\circ}C$ 범위에서 $5{\sim}95ppm$ 농도의 $SO_{2}$ 가스를 주입하고 나서 EMF를 측정하였다. $500^{\circ}C$ 이상의 온도에서 측정된 EMF는 계산치와 일치하였으나, $500^{\circ}C$ 이하에서는 불완전한 평형 때문에 센서의 거동이 불안정하였다. 감응시간은 약 10분 정도 이내였다. 이전지의 안정도와 응답시간으로 보건데, $Na_{2}SiO_{3}(Pt)$를 기준전극으로 하고 순수 $Na_{2}SO_{4}(Pt)$를 지시전극으로한 NASICON 고체전해질은 SOx 측정용의 상업적인 센서물질로써 가능성이 있다.

  • PDF

열적 수직 구조의 장기 변화로부터 유추한 동해 심층수 형성 모드의 변환: 1차원 모델 연구 (Mode Change of Deep Water Formation Deduced from Slow Variation of Thermal Structure: One-dimensional Model Study)

  • 채영기;승영호;강석구
    • Ocean and Polar Research
    • /
    • 제27권2호
    • /
    • pp.115-123
    • /
    • 2005
  • Recently, it has been observed in the East Sea that temperature increases below the thermocline, and dissolved oxygen increase in the intermediate layer but decrease below it. The layer of minimum dissolved oxygen deepens and the bottom homogeneous layer in oxygen becomes thinner. It emerges very probably that these changes are induced by the mode change of deep water formation associated with global warming. To further support this hypothesis, a one-dimensional model experiment is performed. First, a thermal profile is obtained by injecting a cold and high oxygen deep water into the bottom layer, say the bottom mode. Then, two thermal profiles are obtained from the bottom mode profile by assuming that either all the deep water introduce into the intermediate layer has been initiated, say the intermediate mode, or that only a part of the deep water has been initiated into the intermediate layer, say the intermediate-bottom mode. The results, from the intermediate-bottom mode experiment are closest to the observed results. They show quite well the tendency for oxygen to increase in the intermediate layer and the simultaneous thinning of the bottom homogeneous layer in oxygen. Therefore, it can be said that the recently observed slow variation of the thermal structure might be associated with changes in the deep water formation from the bottom mode to the intermediate-bottom mode.

반응성 배수재를 이용한 중금속 오염토양의 정화효율 분석 (Analysis of Heavy Metal Contaminated Soils Remediation Using Reactive Drains)

  • 박정준;최창호;신은철
    • 한국지반신소재학회논문집
    • /
    • 제12권1호
    • /
    • pp.29-38
    • /
    • 2013
  • 본 논문에서는 생분해 배수재를 이용한 오염토양 정화기술의 현장적용성을 평가하기 위하여 생분해 배수재의 물리적 특성시험을 수행하였으며, 이를 이용한 현장실험을 통하여 중금속 오염토양의 정화효율을 분석하였다. 두 종류(실린더 코어형, 하모니카형)의 생분해 배수재에 대한 시험결과, 실린더 코어형 배수재의 경우, 한국산업규격 표준시방에서 제시하는 기준치를 모두 만족하였으며, 하모니카형 생분해성 배수재는 실린더 코어형 배수재에 비해 배수성능이 상당히 낮은 결과를 나타내었다. 또한 오염토양 복원시 사용한 세정제로는 자체독성이 적어 생태계에 미치는 영향을 최소화하며, 생물학적 재순환시스템과의 최적인 조건을 지니고 있는 시트르산(ctric acid)을 선정하여 중금속 중 Cd, Cu, Pb을 현장실험 대상 오염물질로 선정 후 실험을 수행하였다. 현장실험은 3가지 설치조건을 고려하여 정화효율을 분석하였으며, 반응물질이 도포된 생분해 배수재를 이용하여 세척제를 주입 추출을 동시에 수행한 경우가 복원효율이 가장 높은 것으로 평가되었다.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

EXPERIMENTAL ANALYSES OF SPALLATION NEUTRONS GENERATED BY 100 MEV PROTONS AT THE KYOTO UNIVERSITY CRITICAL ASSEMBLY

  • Pyeon, Cheol Ho;Azuma, Tetsushi;Takemoto, Yuki;Yagi, Takahiro;Misawa, Tsuyoshi
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.81-88
    • /
    • 2013
  • Neutron spectrum analyses of spallation neutrons are conducted in the accelerator-driven system (ADS) facility at the Kyoto University Critical Assembly (KUCA). High-energy protons (100 MeV) obtained from the fixed field alternating gradient accelerator are injected onto a tungsten target, whereby the spallation neutrons are generated. For neutronic characteristics of spallation neutrons, the reaction rates and the continuous energy distribution of spallation neutrons are measured by the foil activation method and by an organic liquid scintillator, respectively. Numerical calculations are executed by MCNPX with JENDL/HE-2007 and ENDF/B-VI libraries to evaluate the reaction rates of activation foils (bismuth and indium) set at the target and the continuous energy distribution of spallation neutrons set in front of the target. For the reaction rates by the foil activation method, the C/E values between the experiments and the calculations are found around a relative difference of 10%, except for some reactions. For continuous energy distribution by the organic liquid scintillator, the spallation neutrons are observed up to 45 MeV. From these results, the neutron spectrum information on the spallation neutrons generated at the target are attained successfully in injecting 100 MeV protons onto the tungsten target.

생쥐 수정란의 핵이식에 관한 연구 I. 모성 및 부성 genome의 기능차이에 관한 연구 (Studies on nuclear transplantation in mouse embryos. I. Functional differences between maternal and paternal genomes)

  • 최상용;박충생;이효종;박희성
    • 대한수의학회지
    • /
    • 제30권2호
    • /
    • pp.123-127
    • /
    • 1990
  • 모성 및 부성 genome의 기능을 알아보기 위하여 미세조작기법과 Sendai virus를 이용한 핵융합 기술을 이용하여 2개의 자성전핵만으로 구성된 2배체의 gynogenetic 수정란을 그리고 2개의 웅성전핵만으로 구성된 2배체의 androgenetic 수정란을 인위적으로 작출하였다. 이들의 작출효율은 biparental 수정란에서는 56%, gynogenetic 수정란에서는 50% 그리고 androgenetic 수정란에서는 56% 이었다. 이들을 체외에서 배양한 결과 gynogenetic 및 androgenetic 수정란은 2-세포기 이후에는 biparental 및 intact 수정란에 비하여 그 발달능이 매우 저조하였으나 이들 중 25% 이상이 포배까지 발달한 수 있음을 확인하였다. Gynogenetic 및 androgenetic 수정란을 동기화된 수란생쥐의 난관내에 이식하였던 바, androgenetic 수정란은 전혀 착상 되지 않았으나, gynogenetic 수정란에서는 착상이 확인되었다. 핵이식기법으로 인위조작된 2배체의 biparental 수정란으로부터 28마리의 생쥐 신생자를 생산하였다.

  • PDF

유리섬유 보강재로 제작한 레진의치의 온성 전·후에 따른 정확성 평가 (Accuracy evaluation of resin complete denture made with glass fiber mesh reinforcement before and after curing)

  • 김동연;정일도;박진영;강신영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.25-33
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate accuracy of glass fiber mesh complete denture of before and after curing. Methods: Edentulous model was selected as the master model. Ten study models were made by Type IV stone. Wax complete dentures were produced by the denture base and artificial teeth. CD and GD groups were measured six measurement distance before curing. The wax complete denture was investment after measurement is completed. Using a heat polymerization resin was injected resin. After injecting the resin it was curing. A complete denture was re-measured after curing. The measured data was verified by paired t-test. Results: Overall CD group was larger the value of the measured length. In the CD group, A-D point was larger. The smallest point was the B-D point. However, there was no statistically significant difference only C-D point(p>0.05). In the GD group, A-B point was larger. but B-D point was the smallest. A-D and B-C statistically points showed significant differences(p<0.05). Conclusion: Glass fiber mesh resin complete denture can be clinically applied to the edentulous patient.

방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구 (A study for its Characteristics with Electric Variation in an Electrical Discharge Machining)

  • 신근하
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 춘계학술대회 논문집
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

지반조건에 따른 친환경 바이오그라우팅 주입 효과에 관한 연구 (A Study on the Effectiveness of Injection in Environmentally-Friendly Bio-grouting with Soil Conditions)

  • 김대현;박경호;김민석;김선학
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4276-4283
    • /
    • 2015
  • 본 연구에서는 미생물 반응으로 생성된 탄산칼슘을 현장에서 활용되고 있는 주입장비와 유사하게 제작하여 모래지반에 주입함으로 지반조건에 따른 주입범위 및 주입효과를 확인하고자 하였다. 본 연구를 위해 2종류의 단층토(SP, SW)를 D 150mm ${\times}$ H 300mm의 모형토조에 상대다짐도 80, 85, 90, 95%로 제작하여 주입실험을 수행하였다. 주입 후 강도개선효과를 확인하기 위해 일축압축강도를 측정하였고, 주입노즐 주변의 구근형성을 통해 주입범위를 살펴보았다. 그 결과, SW시료는 상대다짐도 85% 이상에서 주입률이 10% 이하로 나타났으며, 지반의 상대다짐도에 따라 Bio-grouting의 주입률 및 고결범위에 영향이 있음을 확인 할 수 있었다.