• Title/Summary/Keyword: initial working condition

Search Result 47, Processing Time 0.024 seconds

Biological Treatment on Wastewater of Soluble Metal Working Fluids (수용성 금속가공유 폐액의 생물학적 처리)

  • 차미선;한창민;박근태;조순자;손홍주;이상준
    • Journal of Life Science
    • /
    • v.13 no.6
    • /
    • pp.917-923
    • /
    • 2003
  • The present investigation was conducted to determine the chemical oxygen demand (COD) removal efficiency by Pseudomonas aeruginosa EMS1. The COD removal efficiency in the medium containing 1% metal working fluid (MWF) was 12% after cultivation of 4 days. The composition of optimum medium for the COD removal efficiency of 1% MWF by P. aeruginosa EMS1 were NH$_4$Cl 0.3%,$ K_2HPO_4\; 0.05%,\; KH_2PO_4\; 0.04%,\; MgSO_4.7H_2O\; 0.05%,\; CaCl_2.2H_2O 0.03%$ and $FeSO_4.7H_2O$ 0.04% at initial pH 7.0 and $30^{\circ}C$. Under this condition, the highest the COD removal efficiency was observed after 4 days.

Effects of a Case-Based Sepsis Education Program for General Ward Nurses on Knowledge, Accuracy of Sepsis Assessment, and Self-efficacy

  • Kim, Bohyun;Jeong, Younhee
    • Journal of Korean Biological Nursing Science
    • /
    • v.22 no.4
    • /
    • pp.260-270
    • /
    • 2020
  • Purposes: Sepsis is a critical condition in which nurses should detect clinical manifestations and provide early intervention to prevent unwanted serious conditions in the patients. The initial occurrence and management of sepsis take place in general units, but there is a lack of knowledge in nurses. The purpose of this study was to examine the effects of a case-based sepsis education program and compare the case-based education program with and without smartphone applications. Methods: A quasi-experimental pre-test-post-test design with a control group was used. We provided a case-based education program with and without smartphone applications to the nurses and tested the effects of the program on knowledge, the accuracy of sepsis assessment, and self-efficacy as outcome variables. A total of 60 nurses in general units participated. To test differences in knowledge, the accuracy of sepsis assessment, and self-efficacy regarding sepsis between the groups over time, a mixed-design ANCOVA was used for parametric analysis, and generalized estimating equations (GEE) were used for nonparametric analysis. Results: There were significant differences in knowledge, the accuracy of sepsis assessment, and self-efficacy between the groups and within the groups over time. The intervention groups treated with the case-based education program showed improved outcome variables compared to the control group. There was no difference between case-based education with the smartphone application or without the application. Conclusions: The case-based education improved knowledge, the accuracy of sepsis assessment, and self-efficacy in the care of sepsis by nurses working in the general wards. The results suggest that the case-based education program for nurses was effective and eventually improved patient health outcomes.

Analysis Operating Characteristics of Matrix-Type Superconducting Fault Current Limiter in Ground Faults of Power Grid (전력계통의 지락사고에 대한 매트릭스형 초전도 한류기의 동작특성)

  • Oh, Kum-Gon;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Seong-Bo;Kim, Deog-Goo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.14-20
    • /
    • 2009
  • It is very important for power stability to suppress the excessive fault current happened frequently in the real power grid The superconducting fault current limiter (SFCL) is one of the most effective ways to reduce the fault current among the facilities developed so far. In this paper, we have investigated the operating characteristics of the power grid with the SFCL according to three types such as the single, double and triple line-to-ground faults. In addition, we analyzed the consumption power of the superconducting units based on the working data of the SFCL. We confirmed that the fault current could be limited lower than its peak value to 85 percentage in initial fault condition and to 85 percentage after one cycle in the matrix-type SFCL. The consumption powers of the superconducting units were almost equal by reduction of the difference of the critical current between superconducting units element.

Pharmacokinetic Modelling and Simulation of the Counter-transport in the Hepatic Transport of Organic Anions (음이온계 약물의 간수송과정에 있어서 대향수송의 약물동력학적 모델링 및 시뮬레이션)

  • Song, Suk-Gil;Lee, Jun-Seup;Chung, Youn-Bok
    • YAKHAK HOEJI
    • /
    • v.49 no.4
    • /
    • pp.275-283
    • /
    • 2005
  • The purpose of the present study was to kinetically investigate the carrier-mediated uptake in the hepatic transport of organic anions, and to simulate the 'in vivo counter-transport' phenomena, using kinetic model which was developed in this study. The condition that the mobility of carrier-ligand complex is greater than that of free carrier is not essential for the occurrence of 'counter-transport' phenomenon. To examine the inhibitory effects on the initial uptake of organic anions by the liver, it is necessary to judge whether the true counter-transport mechanism (trans-stimulation) is working or not. Effects of bromophenol blue (BPB) or bromosulfophthalein (BSP) on the plasma disappearance curves of a 1-anilino-8-naphthalene sulfonate (ANS) were then kinetically analyzed based on a flow model, in which the ligand is eliminated only from the peripheral compartment (liver compartment). Moreover, 'in vivo counter-transport' phenomena were simulated based on the perfusion model which incorporated the carrier-mediated transport and the saturable intracellular binding. The 'in vivo counter-transport' phenomena in the hepatic transport of a organic anions were well demonstrated by incorporating the carrier-mediated process. However, the 'in vivo counter-transport' phenomena may be also explained by the enhancement of back diffusion due to the displacement of intracellular binding. In conclusion, one should be more cautious in interpreting data obtained from so-called 'in vivo counter-transport' experiments.

Numerical Analysis on Effects of Radius Ratio in a Concentric Annulus with a Rotating Inner Cylinder (내부회전실린더를 가진 동심환형관에서 반경비의 영향에 관한 수치해석적 연구)

  • Bae, Kang-Youl;Kim, Hyoung-Bum;Lee, Sang-Hyuk
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.327-330
    • /
    • 2006
  • This paper represents the numerical analysis on effects of radius ratio in a concentric annulus with a rotating inner cylinder. The numerical model consisted of two cylinder which inner cylinder is rotating and outer cylinder is fix, and the axial direction is used the cyclic condition because of the length for axial direction is assumed infinite. The diameter of inner cylinder is assumed 86.8mm, the numerical parameters are angular velocity and radius ratio. Also, the whole walls of numerical model have no-slip and the working fluid is used water at $20^{\circ}C$. The numerical analysis is assumed the transient state to observe the flow variations by time and the 3-D cylindrical coordinate system. The calculation grid adopted a non-constant grid for dense arrangement near the wall side of cylinder, the standard $k-{\omega}$ high Reynolds number model to consider the effect of turbulence flow and wall, the fully implicit method for time term and the quick scheme for momentum equation. The numerical method is compared with the experimental results by Wereley and Lueptow, and the results are very good agreement. As the results, TVF isn't appeared when Re is small because of the initial flow instability is disappear by effect of the centrifugal force and viscosity. The vortex size is from 0.8 to 1.1 for TVF at various $\eta$, and the traveling distance for wavy vortex have the critical traveling distance for each case.

  • PDF

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part II Design of Lab Scale Dump Combustor (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part II 모형 덤프 연소기 설계)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.51-59
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

Managing Mental Health during the COVID-19 Pandemic: Recommendations from the Korean Medicine Mental Health Center

  • Hyo-Weon Suh;Sunggyu Hong;Hyun Woo Lee;Seok-In Yoon;Misun Lee;Sun-Yong Chung;Jong Woo Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.102-130
    • /
    • 2022
  • Objectives: The persistence and unpredictability of coronavirus disease (COVID-19) and new measures to prevent direct medical intervention (e.g., social distancing and quarantine) have induced various psychological symptoms and disorders that require self-treatment approaches and integrative treatment interventions. To address these issues, the Korean Medicine Mental Health (KMMH) center developed a field manual by reviewing previous literature and preexisting manuals. Methods: The working group of the KMMH center conducted a keyword search in PubMed in June 2021 using "COVID-19" and "SARS-CoV-2". Review articles were examined using the following filters: "review," "systematic review," and "meta-analysis." We conducted a narrative review of the retrieved articles and extracted content relevant to previous manuals. We then created a treatment algorithm and recommendations by referring to the results of the review. Results: During the initial assessment, subjective symptom severity was measured using a numerical rating scale, and patients were classified as low- or moderate-high risk. Moderate-high-risk patients should be classified as having either a psychiatric emergency or significant psychiatric condition. The developed manual presents appropriate psychological support for each group based on the following dominant symptoms: tension, anxiety-dominant, anger-dominant, depression-dominant, and somatization. Conclusions: We identified the characteristics of mental health problems during the COVID-19 pandemic and developed a clinical mental health support manual in the field of Korean medicine. When symptoms meet the diagnostic criteria for a mental disorder, doctors of Korean medicine can treat the patients according to the manual for the corresponding disorder.

TOPICAL GENE DELIVERY TO NORMAL ORAL EPITHELIUM USING ADENOVIRUS IN ORGAN CULTURE MODEL (조직 배양 모형에서 정상 구강 점막 상피에 대한 국소 유전자 요법)

  • Kim, Tae-Hwan;Kwak, Myung-Ho;Lee, Choon-Ho;Park, Jun-Woo;Park, Young-Wook;Kim, Seong-Gon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.193-197
    • /
    • 2009
  • Background: Though it is clear that many types of viruses can infect the oral mucosa, its condition for infection is unclear. The purpose of this study was to analyze the conditions for viral infection of normal oral mucosa and explore the possibility of topical gene therapy to oral mucosa using a viral vector. Methods: Freshly taken fragments of the palate and the tongue of mice were used for organ culture. The specimens were exposed to green fluorescent protein (GFP)-adenoviral vector for 1 hour except for the control. Initial viral titer was $6.3{\times}10^{11}\;pfu/ml$ and the virus was diluted to working concentrations. The dilution ratio was 1:1,000 ($6.3{\times}10^8\;pfu/ml$), 1:10,000 ($6.3{\times}10^7\;pfu/ml$), and 1:100,000 ($6.3{\times}10^6\;pfu/ml$). They were then cultured on a stainless steel wire mesh in an organ culture dish. The specimens were stereoscopically examined every 24 hours for 6 days, after which they were fixed and analyzed through immunohistochemical methods Results: There was no visible expression in the control, $6.3{\times}10^6\;pfu/ml$, and $6.3{\times}10^7\;pfu/ml$ groups. Initial expression was observed at 24 hours after infection in both the palate and the tongue in $6.3{\times}10^8\;pfu/ml$ and the expression significantly increased until 3 days in the palate and 2 days in the tongue after infection (P<0.05). In both groups, the expression was mostly observed at the resection margin. Immunohistochemical studies showed that the epithelial cells were positive to GFP. Conclusion: The present study showed that topically applied adenovirus containing specific genetic information of GFP could successfully transduce GFP in normal oral epithelial cells at the resection margin in organ culture in terms of dose and exposure time.

Design of an Improved Anti-Collision Unit for an RFID Reader System Based on Gen2 (Gen2 리더 시스템의 개선된 충돌방지 유닛 설계)

  • Sim, Jae-Hee;Lee, Yong-Joo;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2A
    • /
    • pp.177-183
    • /
    • 2009
  • In this paper, we propose an improved anti-collision algorithm. We have designed an anti-collision unit using this algorithm for the 18000-6 Type C Class 1 Generation 2 standard (Gen2). The Gen2 standard uses a Q-algorithm for incremental method on the Dynamic Slot-Aloha algorithm. It has basically enhanced performance over the Slot-Aloha algorithm. Unfortunately, there are several non-clarified parts: initial $Q_{fp}$ value, weighted C, and the ending point of the algorithm. If an incorrect value is selected, it causes degradation in performance. Thus we propose an improved anti-collision algorithm by clearly defining the vague parts of the existing algorithm. Simulation results showed an improved performance of up to 34.8% using an optimized value of C and the initial $Q_{fp}$ value. With the ending condition, performance is 34.7%. The anti-collision unit is designed using the Verilog HDL. The module was synthesized using Synopsys' Design Compiler and the TSMC $0.2{\mu}m$ standard cell library. The synthesized result yielded 3,847 gates, and was guaranteed under the proposed working frequency of 19.2MHz.

A Design on the Multimedia Fingerprinting code based on Feature Point for Forensic Marking (포렌식 마킹을 위한 특징점 기반의 동적 멀티미디어 핑거프린팅 코드 설계)

  • Rhee, Kang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.4
    • /
    • pp.27-34
    • /
    • 2011
  • In this paper, it was presented a design on the dynamic multimedia fingerprinting code for anti-collusion code(ACC) in the protection of multimedia content. Multimedia fingerprinting code for the conventional ACC, is designed with a mathematical method to increase k to k+1 by transform from BIBD's an incidence matrix to a complement matrix. A codevector of the complement matrix is allowanced fingerprinting code to a user' authority and embedded into a content. In the proposed algorithm, the feature points were drawing from a content which user bought, with based on these to design the dynamical multimedia fingerprinting code. The candidate codes of ACC which satisfied BIBD's v and k+1 condition is registered in the codebook, and then a matrix is generated(Below that it calls "Rhee matrix") with ${\lambda}+1$ condition. In the experimental results, the codevector of Rhee matrix based on a feature point of the content is generated to exist k in the confidence interval at the significance level ($1-{\alpha}$). Euclidean distances between row and row and column and column each other of Rhee matrix is working out same k value as like the compliment matrices based on BIBD and Graph. Moreover, first row and column of Rhee matrix are an initial firing vector and to be a forensic mark of content protection. Because of the connection of the rest codevectors is reported in the codebook, when trace a colluded code, it isn't necessity to solve a correlation coefficient between original fingerprinting code and the colluded code but only search the codebook then a trace of the colluder is easy. Thus, the generated Rhee matrix in this paper has an excellent robustness and fidelity more than the mathematically generated matrix based on BIBD as ACC.