• Title/Summary/Keyword: initial stability

Search Result 1,386, Processing Time 0.024 seconds

An Optimal Initial Configuration of a Humanoid Robot (인간형 로봇의 최적 초기 자세)

  • Sung, Young-Whee;Cho, Dong-Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.167-173
    • /
    • 2007
  • This paper describes a redundancy resolution based method for determining an optimal initial configuration of a humanoid robot for holding an object. There are three important aspects for a humanoid robot to be able to hold an object. Those three aspects are the reachability that guarantees the robot to reach the object, the stability that guarantees the robot to remain stable while moving or holding the object, and the manipulability that makes the robot manipulate the object dexterously. In this paper, a humanoid robot with 20 degrees of freedom is considered. The humanoid robot is kinematically redundant and has infinite number of solutions for the initial configuration problem. The complex three-dimensional redundancy resolution problem is divided into two simple two-dimensional redundancy resolution problems by incorporating the symmetry of the problem, robot's moving capability, and the geometrical characteristics of the given robot. An optimal solution with respect to the reachability, the stability, and the manipulability is obtained by solving these two redundancy resolution problems.

Design of Stable Time-varying Sliding Mode System

  • Kim, Ga-Gue;Ma, Jin-Suk;Lim, Chae-Deok;Choi, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.62.2-62
    • /
    • 2001
  • In this paper, we present a new time-varying sliding mode system that guarantees stable error convergence. The previous papers have dealt with stability of the time-varying sliding mode system by point-wisely investigating the stability of time-invariant system every time. However, it may be unstable even though it guarantees time-invariant stability every time, We designed the time-varying sliding surface so that the resultant time-varying system on sliding mode may be Stable. The initial sliding surface is obtained so that shifting distance of the surface may be minimized with respect to an initial error, and the intercept is produced so that the surface may pass the initial error.

  • PDF

An Improved Stability Design of Steel Cable-Stayed Bridges using Second-Order Effect (2차효과를 고려한 강사장교의 개선된 좌굴해석)

  • Kyung Yong-Soo;Kim Nam-Il;Lee Jun-Sok;Kim Moon-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.993-1000
    • /
    • 2006
  • Practical stability design method of main members of cable-stayed bridges is proposed and discussed through a design example. For this purpose, initial tensions of stay cables and axial forces of main members are firstly determined using initial shaping analysis of bridges under dead loads. And then the effective buckling length using system elastic/inelastic buckling analysis and bending moments considering $P-{\delta}-{\Delta}$ effect by second-order elastic analysis are calculated for main girder and pylon members subjected to both axial forces and moments, respectively. Particularly, load combinations of dead and live loads, in which maximum load effects due to live loads are obtained, are taken into account and effects of live loads on effective buckling lengths are investigated.

  • PDF

Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis (Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석)

  • Kim, Deug-Han;Pang, Eun-Kyoung;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.339-348
    • /
    • 2009
  • Purpose: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. Methods: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. Results: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. Conclusions: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period.

Stability of Nano-emulsions prepared upon Change of Composition (조성변화에 따라 제조된 나노에멀젼의 안정성)

  • Cho, Wan Goo;Kim, Eun Hee;Jeon, Bong-Ju;Cha, Young-Kweon;Park, Seon-Ki
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • Applications of nano-emulsion for cosmetics as a means of promoting dermal absorption have been the subject of interest. In this study, the stability of nano-emulsions prepared by low-energy emulsification method and varying the composition of raw materials was investigated. By measuring the particle size of the nano-emulsion against time, the stability of nano-emulsions prepared by adding polyol to water phase was increased significantly compared with the nano-emulsions prepared by adding polyol to ethanol phase. The speed of adding ethanol phase to water phase did not have a significant impact on the particle size and stability. Depending on the type of oil, stability was not affected. However, there would be a correlation between the initial size of the nano-emulsion droplets and the molecular weight and polarity of the oil. Stability and the initial particle size according to the type of polyols showed a similar trend except 1,2 hexanediol. The initial droplet size was affected by the concentration of surfactant and oil. However, the initial droplet size did not change against time. Concentration of ethanol was observed to have a significant impact on the initial particle size and stability.

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems (Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교)

  • Oh, Jun-Ho;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

How does the Operational Value Affect the Determination of Initial Fees in Franchise Restaurant Businesses? Based on a Value-Based Pricing Strategy (프랜차이즈 외식기업의 운영적 가치가 초기가맹비용결정에 미치는 영향: 가치기반 가격결정전략을 기반으로)

  • Seung Hyun KIM;Kyung A SUN
    • The Korean Journal of Franchise Management
    • /
    • v.14 no.4
    • /
    • pp.35-50
    • /
    • 2023
  • Purpose: This study aims to uncover the mechanism of how initial fees are determined in the restaurant franchise business. Since the initial fees can be considered as a price of utilizing business models and operational knowledge of a certain franchise brand, it is critical to understand the fee decision-making process based on the strategic pricing theories. Therefore, this study investigates the influence of operational value on the determination of initial franchise fees grounded on a value-based pricing strategy. The Operational value is specifically categorized into profitability, growth, and stability of the franchise system. Research design, data, and methodology: The data used were collected through franchise disclosure documents and brand equity index provided by Korea Management Association Consulting. Data from 44 franchise restaurants during 2018 to 2021 are included in the sample. The panel dataset was analyzed by using generalized least squares estimation with R-Studio. Results: Profitability and stability positively influence initial franchise fees. However, growth did not influence initial franchise fees. Conclusions: The results of the study demonstrate that the operational value plays a critical role in determining the franchise fees. Specifically, franchisees recognize how much revenue a franchise system generates for them (i.e., profitability) and how stable the entire system is for operating business (i.e., stability) when they make purchasing decisions for franchise. The findings extend the pricing literature by applying pricing theories in the franchise fee context. Also, the study contributes to franchising and restaurant management literature by providing knowledge of how franchise fees are determined.

Vibration and stability of initially stressed sandwich plates with FGM face sheets in thermal environments

  • Chen, Chun-Sheng;Liu, Fwu-Hsing;Chen, Wei-Ren
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.251-261
    • /
    • 2017
  • In this paper, thermal effect on the vibration and stability of initially stressed sandwich plates with functionally graded material (FGM) face sheets is analyzed. Material properties of FGM face sheet are graded continuously in the thickness direction. The variation of FGM properties assumes a simple power law distribution in terms of the volume fractions of the constituents. The governing equations of arbitrarily initially-stressed sandwich plates including the effects of transverse shear deformation and rotary inertia are derived. The initial stress is taken to be a combination of a uniaxial extensional stress and a pure bending stress in the examples. The eigenvalue problems are formed to study the vibration and buckling characteristics of simple supported initially stressed FGM/metal/FGM plates. The effects of volume fraction index, temperature rise, initial stress and layer thickness of metal on the natural frequencies and buckling loads are investigated. The results reveal that the volume fraction index, initial stresses and layer thickness of metal have significant influence on the vibration and stability of sandwich plates with FGM face sheets.

Study of Driving and Thermal Stability of Anode-type Ion Beam Source by Charge Repulsion Mechanism

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • v.27 no.3
    • /
    • pp.47-51
    • /
    • 2018
  • We fabricated an anode-type ion beam source and studied its driving characteristics of the initial extraction of ions using two driving mechanisms: a diffusion phenomenon and a charge repulsion phenomenon. For specimen exposed to the ion beam in two methods, the surface impurity element was investigated by using X-ray photoelectron spectroscopy. Upon Ar gas injection for plasma generation the ion beam source was operated for 48 hours. We found a Fe 2p peak 5.4 at. % in the initial ions by the diffusion mechanism while no indication of Fe in the ions released in the charge repulsion mechanism. As for a long operation of 200 min, the temperature of ion beam sources was measured to increase at the rate of ${\sim}0.1^{\circ}C/min$ and kept at the initial value of $27^{\circ}C$ for driving by diffusion and charge repulsion mechanism, respectively. In this study, we confirmed that the ion beam source driven by the charge repulsion mechanism was very efficient for a long operation as proved by little electrode damage and thermal stability.

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.