• Title/Summary/Keyword: initial bulk concentration

Search Result 38, Processing Time 0.026 seconds

Analysis of Bulk Concentration on Double-Layer Structure for Electrochemical Capacitors

  • Khaing, Khaing Nee Nee;Hla, Tin Tin
    • Korean Journal of Materials Research
    • /
    • v.32 no.7
    • /
    • pp.313-319
    • /
    • 2022
  • Double-layer capacitors (DLCs) are developed with high surface electrodes to achieve a high capacitance value. In the present work, the initial bulk concentration of 1 mol/m3 and 3 mol /m3 are selected to show the consequential effects on the performance of a double-layer capacitor. A 1D model of COMSOL Multiphysics has been developed to analyze the electric field and potential in cell voltage, the electric displacement field and polarization induced by the field, and energy density in a double-layer structure. The electrostatics and the electric circuit modes in COMSOL are used to simulate the electrochemical processes in the double-layer structure. The analytical analysis of a double-layer capacitor with different initial bulk concentrations is investigated by using Poisson-Nernst-Plank equations. From the simulation results, the differential capacitance changes as a function of compact layer thickness and initial bulk concentration. The energy density varies with the differential capacitance and voltage window. The values of energy density are dominated by the interaction of ions in the solution and electrode surface.

A comparative study for the decay of chlorine residual using EPANET2.0 and an experimental pipeline system (EPANET 2.0과 관망실험을 통한 배수관망 염소농도 감쇄 비교연구)

  • Baek, Dawon;Kim, Hyunjun;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.411-419
    • /
    • 2018
  • The residual chlorine concentration is an essential factor to secure reliable water quality in the water distribution systems. The chlorine concentration decays along the pipeline system and the main processes of the reaction can be divided into the bulk decay and the wall decay mechanisms. Using EPANET 2.0, it is possible to predict the chlorine decay through bulk decay and wall decay based on the pipeline geometry and the hydraulic analysis of the water distribution system. In this study, we tried to verify the predictability of EPANET 2.0 using data collected from experimental practices. We performed chlorine concentration measurement according to various Reynolds numbers in a pilot-scale water distribution system. The chlorine concentration was predicted using both bulk decay model and wall decay model. As a result of the comparison between experimental data and simulated data, the performance of the limited $1^{st}$-order model was found to the best in the bulk decay model. The wall decay model simulated the initial decay well, but the overall chlorine decay cannot be properly predicted. Simulation also indicated that as the Reynolds number increased, the impact of the wall.

The Effects of high Energy(1.5MeV) B+ ion Implantation and Initial Oxygen Concentration Upon Deep Level in CZ Silicon Wafer (고 에너지 (1.5 MeV) Boron 이온 주입과 초기 산소농도 조건이 깊은 준위에 미치는 영향에 관한 연구)

  • Song, Yeong-Min;Mun, Yeong-Hui;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.55-60
    • /
    • 2001
  • The effect of high energy B ion implantation and initial oxygen concentration upon defect formation and gettering of metallic impurities in Czochralski silicon wafer has been studied by applying DLTS( Deep Level Transient Spectroscopy), SIMS(Secondary ton Mass Spectroscopy), BMD (Bulk Micro-Defect) analysis and TEM(Transmission Electron Microscopy). DLTS results show the signal of the deep levels not only in as-implanted samples but also in low and high temperature annealed samples. Vacancy-related deep levels in as- implanted samples were changed to metallic impurities-related deep levels with increase of annealing temperature. In the case of high temperature anneal, by showing the lower deep level concentration with increase of initial oxygen concentration, high initial oxygen concentration seems to be more effective compared with the lower initial oxygen one.

  • PDF

Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network (상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발)

  • Jeong, Bobae;Kim, Kibum;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

Separation of Two Amino Acids by Microemulsion Bulk Liquid Membrane

  • Salabat, Alireza;Sanij, Fereshteh Dehghani
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3387-3390
    • /
    • 2012
  • In this research work the potentialities of microemulsion bulk liquid membrane for the selective transport of L-tryptophan (L-Trp) and L-tyrosine (L-Tyr) are investigated at 298.15 K. Reversed micelle formed by sodium bis(2-ethylhexyl)sulfosuccinate (AOT) in dichloroethane, was used as mobile carrier to transport amino acids between a source and a receiving aqueous phase. The effects of pH, surfactant concentration and initial amino acid concentration on the extraction efficiency and transfer rate of the amino acids were studied. It is verified that for a mixture of two amino acids, L-Trp can be extracted selectively by using this type of the bulk liquid membrane with optimized condition.

Contribution of Bulk Flow to Transport Mechanisms of the Membranes Surrounding Amniotic Fluid in the Rabbit

  • Lim, Young-Cheol;Lee, Sang-Jin;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.28 no.1
    • /
    • pp.79-90
    • /
    • 1994
  • The objective of the present study is to assess the contribution of bulk flow to the regulatory mechanism of amniotic fluid volume and its ionic concentration in the membranes surrounding the amniotic fluid. For quantitative assessment, we prepared 4 kinds of artificial amniotic fIuids (isotonic isovolumetric, hypotonic isovolumetric, isotonic hypervolumetric and hypotonic hypervolumetric ones) by replacing 70% of amniotic fluid of pregnant rabbits with water or normal Tyrode solutions. Isoosmotic saline of 0.5 ml volume containing 0.05% Censored and 15 mM/l LiCl was administered initially into amniotic sacs of all subject animals. Samples of amniotic fluid were collected in after 30 and 90 minute intervals; the concentrations of Censored, $Na^+\;and\;Li^+$ were determined and compared. Followings are the results obtained. 1. from isovolumetric and increased Congcord group, we couldn't find significant change in $Li^+\;and\;Na^+$ concentration in isotonic amniotic fluid. However, $Na^+$ concentration increased significantly as well as a striking increase in Censored concentration in hypotonic amniotic fluid. 2. In isovoIumetric and decreased Censored group, the rate of $[Li^+]$ decrement and the rate of $[Na^+]$ increment were much higher in hypotonic amniotic fluid than in isotonic. 3. In hypervolumetric and increased Censored group, the rate of $Na^+$ efflux increased proportionately with the increment of Censored concentration up to 0.98, which was higher than the rate of $Li^+$ efflux in isotonic amniotic fluid. However, the increment of $Na^+$ concentration was rather related with the initial $Na^+$ concentration in hypotonic amniotic fluid, showing inverse relationship. $Li^+$ concentration increased only when there was a marked increase in Censored concentration and approached near a maximum value or 1. 4. For hypervolumetric and decreased Censored group, the observations were identical to isovolumetric and decreased Censored group. From these results the following conclusions could be made: 1) There is no net movement of water or monovalent cations across the membranes surrounding amniotic fIuid in isotonic isovolumetric condition. In contrast, there is a net efflux of amniotic fluid by osmotic bulk flow, resulting in elevation of $Na^+$ concentration in hypotonic isovolumetric condition. 2) In hypervolumetric conditions, there is a massive efflux of amniotic fluid or solvent drag through the surrounding membranes by fiItrative bulk flow, where the rate of $Na^+$ efflux has a linear relationship with that of water efflux. This is assumed to be carried out through enlarged and newly opened intercellular spaces resulting from increased intraamniotic pressure. 3) Once increasing intraamniotic pressure reaches a point allowing $Li^+$ to pass through during osmotic bulk flow in hypotonic amniotic fIuid, $Na^+$ influx seems to occur by diffusion simultaneously or immediately thereafter, too.

  • PDF

Adsorptive Binding of Plasma Proteins to Red Blood Cell Ghosts (플라즈마 단백질의 고스트 적혈구 흡착 특성)

  • 김동욱;차운오
    • KSBB Journal
    • /
    • v.11 no.6
    • /
    • pp.630-635
    • /
    • 1996
  • Blood plasma proteins dissolved in isotonic phosphate-buffered saline were found to be adsorbed to red blood cell ghosts suspended in the solution. This was evidenced by concentration reduction of the plasma proteins in the bulk solution. For initial concentration of 0.1mg/mL immuno globulin, concentration reduction increased from 14% to 45% as the volume fraction of red blood cell ghosts in the solution increased from 5% to 45%. For initial concentration of 0.075mg/mL albumin, the concentration reduction increased from 12% to 47% as the volume fraction of red blood cell ghosts in the solution increased from 5% to 70%. The concentration reduction of plasma proteins in hardened red blood cell ghosts was higher than that in red blood cell ghosts. The number of adsorbed protein molecules per a red blood cell ghost were reduced as volume fraction of the ghosts in the solution increased.

  • PDF

A Study on the Initial Behavior of Dredged Material Disposal in the Coastal Water (연안수역에서 투기준설토의 초기거동에 관한 연구)

    • Journal of Korean Port Research
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 1995
  • Investigation of the physical behavior of dredged material disposal in coastal water includes estimations of water column concentration in the receiving water, exposure time, the initial deposition pattern as well as thickness of material at the dumping fields near the estuary area. Calculation based on vertical setting and horizontal advection of single particles ignore the effects of bulk properties of the disposed material, vertical and horizontal diffusion, and material dilution due to the entrainment of ambient water during descent. This paper focuses on the spatial and temporal changes in the dumping fields for the water column and bottom at a hypothetically confined coastal water, where the ambient time-invariant velocity and density profiles are applied, within the initial time period following the instantaneous release of the dredged material. This model accounts the behavior of material after release divided into three phases: convective descent, dynamic collapse and long-term passive dispersion

  • PDF

Biosorption of lead by Laminaria japonica

  • Jung-Ho;Il-Bae;Hak-Sung
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.208-211
    • /
    • 2003
  • Characteristics of biosorption of lead by marine algae, Laminaria japonica, were examined. The biosorption capacity of lead by L. japonica was achieved up to 30% of its own weight and proportional to the initial lead concentration. However, the opposite result was shown in different initial weight of biomass. Ion exchange reaction between lead ions and calcium ions was observed on lead biosorption with Ca-Ioaded biomass. Stoichiometric coefficient, which can represent the exchange ratio between metal ions and protons during elution process, was determined as 1.39. Therefore, it was concluded that the reaction between lead ions already attached in biomass and protons in bulk solution was not fully stoichiometric ion exchange relation at elution process.

  • PDF

포말 분리법에 의한 양어장의 단백질 제거

  • 서근학;이회근
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.41-45
    • /
    • 1998
  • The feasibility of foam separation to remove protein in aquacultural recirculating water was investigated. From the results of batch foam separation on protein removal, superficial air velocity and initial protein concentration in bulk solution were found to be important operational factors In determining removal rates of protein. The protein removal rate by batch foam separation was proportionally increased with the superficial air velocity. Performance characteristics of continous foam separator were highly dependent upon the operating parameters of superficial air velocity, hydraulic retention time(HRT) and foam height. Removal effeciency of protein increases with increasing superficial air velocity and HRT, and independent on foam height. As DO concentration was increased with superficial air velocity, foam separator is also used for oxygen addition. It could be confinned that foam separator might offer better perspective for protein removal in aquacuitural recirculating water.

  • PDF