• 제목/요약/키워드: initial attachment

검색결과 157건 처리시간 0.038초

Polyaryletherketones (PAEKs)로 제작된 임플란트 유지형 어태치먼트의 유지력 평가 (Evaluation of the initial retention of implant-retained attachments made of dental polyaryletherketones (PAEKs))

  • 박수철;김성민
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.61-66
    • /
    • 2023
  • Purpose: The current study examined the retention and wear resistance of stud-type attachments made of high-performance polyetheretherketone (PEEK) or polyetherketoneketone (PEKK) from the polyaryletherketones (PAEKs) family. Methods: The study sample included 10 PEEK or PEKK attachments that were mounted onto their male parts, designed on the upper aspect of the attachment, with a load of 30 N. Tensile stress was applied using an Instron machine to separate the male and female parts, and the maximum tensile stress to be applied was determined based on the retention force observed. The wear resistances of PEEK and PEKK were evaluated by measuring the inner diameter of the inserted female part 10 times. Results: The maximum tensile stresses of PEEK and PEKK were 56.26±0.58 and 69.12±0.92 N, respectively, with the maximum stress required to remove the PEKK specimens from the abutment being 12.86 N higher than that required to remove the PEEK specimens. Furthermore, PEKK exhibited higher wear resistance than PEEK. Conclusion: This study evaluated custom-made removable implant-retained attachment components for overdentures, wherein the female parts were made of PEEK or PEKK. The retention stress and wear resistance were evaluated based on the type of attachment material, and the results showed that both types of attachment inserts demonstrated clinically acceptable results in terms of retention.

폴리에틸렌 담체에 부착된 혐기성 생물막 부착 특성 (Characteristics of attach of biomass on PE substratum under anaerobic condition)

  • 이승란;김도한;나영수;이창한;박영식;윤태경;송승구
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.327-332
    • /
    • 2002
  • Optical microscope, SEM (Scanning Electron Microscopy) and fluorescent microscope were used for qualitative and morphological studies of the attached biomass on PE (polyethylene) substratum under anaerobic condition. It was shown by the observation of optical microscope that the initial attachment of biomass began in crevices of the surface of PE. The shape and structure of the attached biofilm could be observed by SEM photographs, but species of bacteria were and methanogens were not classified. A large number of methanogenic bacteria were identified on the surface of PE substratum by fluorescence under 480nm of radiation. It was estimated that methanogenic bacteria was also related to initial attachment of biomass under anaerobic condition.

법랑기질 단백질 유도체가 치주인대양세포 및 조골양세포에 미치는 영향 (Effects of enamel matrix protein derivatives on the periodontal ligament like fibroblast and osteoblast like cells)

  • 김동운;정진형;임성빈;고선일
    • Journal of Periodontal and Implant Science
    • /
    • 제33권2호
    • /
    • pp.225-246
    • /
    • 2003
  • Recent study on the enamel matrix derivatives explained on the effects of new bone and new attachment formation in infrabony pocket of periodontal defects. The purpose of this study was to investigate on the biological effects of enamel matrix derivatives to attachment, proliferation and activation of periodontal ligament and osteoblast cells, After treatment of osteoblast and PDL cells with various Emdogain concentration level(0.03${\mu}g$/ml, 3${\mu}g$/ml, 300${\mu}g$/ml), activation of osteogenetic factor, calcified nodule formation and measuring alkaline phosphatase activity(ALP) were performed. 1. Both osteoblast and PDL cell showed increasing initial cell attachment with 300${\mu}g$/ml Emdogain concentration. 2. At the level of 300${\mu}g$/ml, accelerated proliferation of oseoblast and PDL cell was appeared. 3. As Emdogain's concentration increased, increased ALP activation of osteoblast was shown. In case of PDL cell, Emdogain increased ALP activation prominently at the level of 300${\mu}g$/ml. 4. No statistically significant activating change were founded at all of the concentrations of Emdogain on the activating of transcript factor Runx2 for differentiating osteoblast. 5. At the level of 300${\mu}g$/ml, calcified nodule formation was increased prominently to compare with other concentration. These results indicated that Emdogain should activate initial attachment, proliferation and activation, but not on Runx2 activation and can be used for useful tool of the treatment of periodontal tissue regeneration.

Fibrin affects short-term in vitro human mesenchymal stromal cell responses to magneto-active fibre networks

  • Spear, Rose L.;Symeonidou, Antonia;Skepper, Jeremy N.;Brooks, Roger A.;Markaki, Athina E.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권3호
    • /
    • pp.143-157
    • /
    • 2015
  • Successful integration of cementless femoral stems using porous surfaces relies on effective periimplant bone healing to secure the bone-implant interface. The initial stages of the healing process involve protein adsorption, fibrin clot formation and cell osteoconduction onto the implant surface. Modelling this process in vitro, the current work considered the effect of fibrin deposition on the responses of human mesenchymal stromal cells cultured on ferritic fibre networks intended for magneto-mechanical actuation of in-growing bone tissue. The underlying hypothesis for the study was that fibrin deposition would support early stromal cell attachment and physiological functions within the optimal regions for strain transmission to the cells in the fibre networks. Highly porous fibre networks composed of 444 ferritic stainless steel were selected due to their ability to support human osteoblasts and mesenchymal stromal cells without inducing untoward inflammatory responses in vitro. Cell attachment, proliferation, metabolic activity, differentiation and penetration into the ferritic fibre networks were examined for one week. For all fibrin-containing samples, cells were observed on and between the metal fibres, supported by the deposited fibrin, while cells on fibrin-free fibre networks (control surface) attached only onto fibre surfaces and junctions. Initial cell attachment, measured by analysis of deoxyribonucleic acid, increased significantly with increasing fibrinogen concentration within the physiological range. Despite higher cell numbers on fibrin-containing samples, similar metabolic activities to control surfaces were observed, which significantly increased for all samples over the duration of the study. It is concluded that fibrin deposition can support the early attachment of viable mesenchymal stromal cells within the inter-fibre spaces of fibre networks intended for magneto-mechanical strain transduction to in-growing cells.

Wettability and cellular response of UV light irradiated anodized titanium surface

  • Park, Kyou-Hwa;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.63-68
    • /
    • 2011
  • PURPOSE. The object of this study was to investigate the effect of UV irradiation (by a general commercial UV sterilizer) on anodized titanium surface. Surface characteristics and cellular responses were compared between anodized titanium discs and UV irradiated anodized titanium discs. MATERIALS AND METHODS. Titanium discs were anodized and divided into the following groups: Group 1, anodized (control), and Goup 2, anodized and UV irradiated for 24 hours. The surface characteristics including contact angle, roughness, phase of oxide layer, and chemical elemental composition were inspected. The osteoblast-like human osteogenic sarcoma (HOS) cells were cultured on control and test group discs. Initial cellular attachment, MTS-based cell proliferation assay, and ALP synthesis level were compared between the two groups for the evaluation of cellular response. RESULTS. After UV irradiation, the contact angle decreased significantly (P<.001). The surface roughness and phase of oxide layer did not show definite changes, but carbon showed a considerable decrease after UV irradiation. Initial cell attachment was increased in test group (P=.004). Cells cultured on test group samples proliferated more actively (P=.009 at day 2, 5, and 7) and the ALP synthesis also increased in cells cultured on the test group (P=.016 at day 3, P=.009 at day 7 and 14). CONCLUSION. UV irradiation induced enhanced wettability, and increased initial cellular responses of HOS cells on anodized titanium surface.

Effects of cp-Ti Surface Roughness and Directionality on Initial Cell Attachment Behaviors

  • Shin, Dong-Hoon;Chun, Sungsu;Ahn, Myun-Whan;Song, In-Hwan;Kim, Sukyoung
    • 대한금속재료학회지
    • /
    • 제50권4호
    • /
    • pp.338-343
    • /
    • 2012
  • The early osseointegration of titanium (Ti) dental implants is related to the initial cell morphology. The morphology of the cells (mesenchymal stem cells, MSC) was observed on three different Ti disc surfaces, which were mechanically treated by polishing, blasting, and scratching. A non-directional surface (isotropic texture) was obtained by the blasting of HA grits on cp-Ti discs, and a unidirectional surface (anisotropic texture) was obtained by the scratching of SiC papers. The cell attachment and arrangement in the initial periods were quite similar, but those in the later periods were significantly affected by the texture of the cp-Ti discs. After 1 week, the blasted Ti discs showed non-directional arrangement or spreading of the cells, whereas the scratched cp-Ti discs showed unidirectional properties parallel to the direction of the scratched grooves on the surface. The surface roughness of the cp-Ti discs significantly affects cell proliferation. Cell proliferation on the blasted and scratched surfaces was about 60% and 40% higher compared to the control result (polishing group) after 1 week (P<0.05). Cell proliferation on the blasted and scratched surfaces after 1 week was slightly enhanced with increasing surface roughness. It is believed that the direction of cell attachment and arrangement is closely related to the surface texture of the substrate surfaces, but cell proliferation after a relatively long period of time is directly enhanced by the surface roughness, not by the surface texture.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

혐기성 BAC 유동층 반응기에서 Start-up 방법 및 미생물 부착 특성 연구 (A Study on the Start-up Method and Characteristics of Microorganisms Attachment in an Anaerobic BAC FluidizedBed Reactor)

  • 박동일;신승훈;안재동;최석규
    • 한국환경보건학회지
    • /
    • 제22권1호
    • /
    • pp.82-90
    • /
    • 1996
  • The objectives of this study were to examine the start-up method and characteristics of biomass attachment on the media in an anaerobic fluidized bed reactor(AFBR). The media adopted was the granular activated carbon which was successfully capable of adsorbing organics and biomass. The reactor was operated at 5 kg $COD/m^3\cdot day$ and 24hr of HRT. There were important problems in the AFBR's start-up, which has been reported very long and unstable. Therefore, this research was to solve the problem of the start-up and it was performed, comparing two start-up ways that were initial fluidized system and initial static-fluidized system. The results were summarized as follows: (1) On the whole initial static-fluidized system was superior to initial fluidized system in the aspects of biogas production rate, methane content and COD removal efficiency etc. (2) At the steady state methane production rate and recoverable bioenergy of initial static-fluidized system were $2.074 m^3CH_4/m^3\cdot day$, $0.488 m^3CH_4/kgCOD_{removed}\cdot day$, and 81.3kcal/day, respectively. (3) Thickness of biofilm was about $5.11 \mu m$, $\rho_{bw}$ and $\rho_{bd}$ were $1.022 g/cm^3, 0.0953g/cm^3$ respectively. (4) Biomass concentration of fluidized state was about 35 mg/g GAC. In conclusion the efficient method on the start-up of the AFBR using GAC as media was initial static-fluidized system and the period of static state needed to reach steady state was considered about twenty days.

  • PDF

임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 (Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment)

  • 최재원;채성기;허중보
    • 대한치과보철학회지
    • /
    • 제59권2호
    • /
    • pp.173-180
    • /
    • 2021
  • 목적: 본 연구는 반복적인 착탈에 따른 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장치의 유지력 특성을 평가해보고자 하였다. 재료 및 방법: 본 연구에서는 새롭게 개발된 유지장치(ADD-Lock; AL)와 기존의 상용화된 유지장치(Locator blue; LB)의 두 가지 유지장치를 평가하였다. 두 개의 고정체를 하부 구조물에 평행하게 위치시키고, 각 유지장치의 patrix를 고정체에 연결하였다. 각 유지장치의 matrix는 대합되는 상부 구조물에 위치시키고 고정하였다. Universal testing machine을 이용하여 초기, 100, 250, 500, 1000, 2000, 2500회의 반복적인 착탈 동안에 각 유지장치의 유지력을 측정하였다. 유지장치의 마모 및 변형 정도는 주사전자현미경으로 관찰하였다. Kruskal-Wallis test, Mann-Whitney U test (α = .05), 그리고 wilcoxon signed-rank test (α = .05)를 이용하여 통계분석 실시하였다. 결과: 초기 유지력과 2500회의 반복적인 착탈 후 유지력에서, AL군(15.24 ± 1.46 N, 9.74 ± 1.16 N)은 LB군(43.53 ± 12.39 N, 22.99 ± 4.77 N)보다 유의하게 작은 값을 보였다(P < .05). 또한, 유지력 소실량에 있어서도 AL군(5.50 ± 1.08 N, 36.08%)이 LB군(20.54 ± 11.89 N, 47.19%)에 비해 낮은 값을 보였다(P < .05). 주사전자현미경 분석 결과, AL군은 patrix에서, LB군은 matrix에서 눈에 띄는 마모 및 변형이 관찰되었다. 결론: Locator는 새롭게 개발된 유지장치보다 높은 초기 유지력을 보인 반면 높은 유지력 소실량을 보였다. 한편, 두 가지 부가적인 유지장치는 반복적인 착탈 후에도 충분한 유지력을 가지는 것으로 나타났다.

여과초기에서의 탈착된 입자의 거동 (Role of Detached Particles During Initial Filtration Phase)

  • 김자겸
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.16-24
    • /
    • 2005
  • Mathematical model was developed to verify a sequential particle removal taking place in a granular media gravity filter. Consequential multi-layer filtration cycle model was applied to verify the fraction of filter effluent particles that are filter influent particles that were never removed as well as the fraction of filter effluent particles that were detached after deposition were performed through laboratory experiments. Three sizes of marker particles were injected ahead of the filter column as a pulse in the presence of four sizes of polystyrene particles that were used as a primary source of particles in the raw suspension to investigate particle attachment alone in contrast to net removal from attachment and detachment. Microscopic counting of filter effluent particles was assumed to reflect attachment. Experimental results indicated that particle detachment is significant beginning from the early phase of filtration. For each size of fluorescent microspheres at one filter depth, fluorescent microsphere removal increased with filter runtime to a maximum due to ripening. The detached fraction of effluent particles increased with particle size and filter depth. The presence of detached particles and the increasing fraction of detached particles in deeper bed were confirmed.