• 제목/요약/키워드: infrared sensors

검색결과 433건 처리시간 0.026초

체감형 스키 시뮬레이터 개발을 위한 플루크보겐 동작의 운동역학적 비교 (Comparisons of Pflugbogen's Biomechanical Characteristics to Develop Interactive Ski Simulator)

  • 구도훈;이민현;권효순;현보람;은선덕
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.189-199
    • /
    • 2014
  • The purpose of this study was to compare pflugbogen's biomechanical characteristics between on the ski simulator and snowed ski slope to develop interactive ski simulator. Nine ski instructors(sex: male, age: $29.6{\pm}5.4yrs$, height: $176.0{\pm}5.6cm$, body mass: $76.0{\pm}14.0kg$) belong to Korean Ski Instructors Association participated in this research. 24 Infrared cameras for snowed ski slope experiment and 13 infrared camera for ski simulator experiment were installed near by path of pflugbogen. The participants did pflugbogen on the snowed ski slope and the ski simulator both. During the experiment, the participants weared motion capture suit with infrared reflective makers on it, and plantar pressure sensors in ski boots, so that ski motion and plantar pressure data were collected together. Displacement of COG(center of gravity) movements, trunk flexion/extension angle, adduction/abduction angle, and plantar pressure data were significantly different between on the simulator and ski slope. However, percentage of time of COG movement in the phases during medial/lateral and anterior/posterior movement were not significantly different. Findings indicate that the difference between two groups occurred because the ski simulator's drive mechanism is different from ski motion on the slope. In order to develop the ski simulator more interactively for pflugbogen, the ski simulator's drive mechanism need to be reflected 3D motion data of pflugbogen on the slope that were purposed in this research.

시간응답특성을 고려한 2광원 1센서 방식의 capnograph 시스템용 NDIR식 $CO_2$ 가스 챔버 설계 및 측정 회로의 구현 (An implementation of NDIR type $CO_2$ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics)

  • 박일용;이인기;이성기;강경목;강신원;조진호
    • 센서학회지
    • /
    • 제10권5호
    • /
    • pp.279-285
    • /
    • 2001
  • 본 논문에서는 동맥혈중 이산화탄소 분압을 실시간으로 추정하는 capnograph 시스템에 상용되는 대부분 NDIR 흡수식(non-dispersive infrared absorption) 광챔버와 신호처리회로를 설계 및 구현하였다. 광챔버 설계시 일반 정상인의 capnogram을 주파수 분석하여 적합한 광쵸핑 주파수를 결정한 뒤, 이에 근거하여 시간응답을 고려한 광챔버를 설계하였으며, 열잡음에 대한 영향을 줄이기 위해 2광원 1센서 방식의 $CO_2$ 농도 신호처리회로를 구현하였다. 구현된 광챔버에 대한 가스배출시간을 조사하였으며 신호처리회로를 외부 온도 변화 실험에 적용한 결과 2광원 1센서 방식이 안정된 출력 신호를 얻을 수 있음을 확인하였고, 실제 사람의 호흡에 대한 실험결과 정상적인 capnogram 형태의 $CO_2$ 농도 변화 곡선을 보였다.

  • PDF

인체 감지용 강유전체 박막 초전형 적외선 센서의 제작 (Pyroelectric Infrared Microsensors Made for Human Body Detection)

  • 최준림
    • 센서학회지
    • /
    • 제7권2호
    • /
    • pp.103-110
    • /
    • 1998
  • 강유전체 박막과 마이크로 가공기술을 이용하여 초전형 적외선 센서를 제작하였다. 초전형 적외선 센서는 $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) (PLT) 강유전체 박막 커패시터를 RF 마그네트론 스퍼터링 방식으로 백감 전극이 증착된 MgO 기판상에 결정 성장시킨 구조를 갖고 있다. 스퍼터링된 PLT 박막은 높은 c-축 결정 구조를 가지므로 센서로 사용하기 위한 분극 처리 과정이 필요 없다. 이는 적외선 이미지 센서를 구현함에 있어서 수율 향상에 필수적인 요소이다. 또한 마이크로 가공 기술을 사용하여 센서의 열용량을 극소화함으로서 센서의 효율을 최대화하였다. 제작된 센서의 상부에 폴리이미드를 코팅하고 MgO 기판을 선택적으로 식각하여 코팅된 폴리이미드와 MgO가 강유전체 박막 커패시터를 지지하고 있는 구조를 구현하였다. 이렇게 제작된 센서의 감도는 상온에서 $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$로 측정되었으며 이는 마이크로 가공 기술을 사용하지 않은 경우보다 약 100 배의 감도 향상을 가져왔다. 2차원 배열 구조를 갖는 센서를 가지고 인체의 유 무 뿐만 아니라 위치까지 감별할 수 있는 센싱 시스템을 구현하였다.

  • PDF

First Light Results of IGRINS Instrument Control Software

  • Lee, Hye-In;Pak, Soojong;Sim, Chae Kyung;Le, Huynh Anh N.;Jeong, Ueejeong;Chun, Moo-Young;Park, Chan;Yuk, In-Soo;Kim, Kangmin;Pavel, Michael;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.54.2-54.2
    • /
    • 2014
  • IGRINS (Immersion GRating Infrared Spectrograph) is a high spectral resolution near-infrared spectrograph that has been developed in a collaboration between the Korea Astronomy & Space Science Institute and the University of Texas at Austin. By using a silicon immersion echelle grating, the size of the fore optics is reduced by a factor of three times and we can make a more compact instrument. One exposure covers the whole of the H- and K-band spectrum with R=40,000. While the operation of and data reduction for this instrument is relatively simple compared to other grating spectrographs, we still need to operate three infrared arrays, cryostat sensors, calibration lamp units, and the telescope during astronomical observations. The IGRINS Instrument Control Software consists of a Housekeeping Package (HKP), Slit Camera Package (SCP), Data Taking Package (DTP), and Quick Look Package (QLP). The SCP will do auto guiding using a center finding algorithm. The DTP will take the echellogram images of the H and K bands, and the QLP will confirm fast processing of data. We will have a commissioning observations in 2014 March. In this poster, we present the performance of the software during the test observations.

  • PDF

비정질 실리콘 희생층을 이용한 니켈산화막 볼로미터 제작 (Fabrication of Nickel Oxide Film Microbolometer Using Amorphous Silicon Sacrificial Layer)

  • 김지현;방진배;이정희;이용수
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.379-384
    • /
    • 2015
  • An infrared image sensor is a core device in a thermal imaging system. The fabrication method of a focal plane array (FPA) is a key technology for a high resolution infrared image sensor. Each pixels in the FPA have $Si_3N_4/SiO_2$ membranes including legs to deposit bolometric materials and electrodes on Si readout circuits (ROIC). Instead of polyimide used to form a sacrificial layer, the feasibility of an amorphous silicon (${\alpha}-Si$) was verified experimentally in a $8{\times}8$ micro-bolometer array with a $50{\mu}m$ pitch. The elimination of the polyimide sacrificial layer hardened by a following plasma assisted deposition process is sometimes far from perfect, and thus requires longer plasma ashing times leading to the deformation of the membrane and leg. Since the amorphous Si could be removed in $XeF_2$ gas at room temperature, however, the fabricated micro-bolomertic structure was not damaged seriously. A radio frequency (RF) sputtered nickel oxide film was grown on a $Si_3N_4/SiO_2$ membrane fabricated using a low stress silicon nitride (LSSiN) technology with a LPCVD system. The deformation of the membrane was effectively reduced by a combining the ${\alpha}-Si$ and LSSiN process for a nickel oxide micro-bolometer.

비분산적외선 CO2 센서를 위한 DBR기반의 패브리 페로-필터 설계 및 성능 연구 (Design and performance study of fabry-perot filter based on DBR for a non-dispersive infrared carbon dioxide sensor)

  • 도남곤;이준엽;정동건;공성호;정대웅
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.250-254
    • /
    • 2021
  • A highly sensitive and selective non-dispersive infrared (NDIR) carbon dioxide gas sensor requires achieving high transmittance and narrow full width at half maximum (FWHM), which depends on the interface of the optical filter for precise measurement of carbon dioxide concentration. This paper presents the design, simulation, and fabrication of a Fabry-Perot filter based on a distributed Bragg reflector (DBR) for a low-cost NDIR carbon dioxide sensor. The Fabry-Perot filter consists of upper and lower DBR pairs, which comprise multilayered stacks of alternating high- and low-index thin films, and a cavity layer for the resonance of incident light. As the number of DBR pairs inside the reflector increases, the FWHM of the transmitted light becomes narrower, but the transmittance of light decreases substantially. Therefore, it is essential to analyze the relationship between the FWHM and transmittance according to the number of DBR pairs. The DBR is made of silicon and silicon dioxide by RF magnetron sputtering on a glass wafer. After the optimal conditions based on simulation results were realized, the DBR exhibited a light transmittance of 38.5% at 4.26 ㎛ and an FWHM of 158 nm. The improved results substantiate the advantages of the low-cost and minimized process compared to expensive commercial filters.

센서 융합을 이용한 이동 로봇의 물체 검출 방법 (Object Detection Method on Vision Robot using Sensor Fusion)

  • 김상훈
    • 정보처리학회논문지B
    • /
    • 제14B권4호
    • /
    • pp.249-254
    • /
    • 2007
  • 본 논문에서는 초음파 및 적외선 센서와 무선 카메라를 장착한 소형 이동 로봇의 물체 검출 방법을 제시한다. 전방 물체의 존재 여부를 판단하기 위해, 초음파 센서는 초음파 발생 신호의 귀환시간, 적외선 센서는 감지한 적외선 아날로그신호의 양, 카메라는 영상 데이터 중 물체의 특징 등을 추출하여 그 결과를 융합함으로써 물체의 유무 또는 이동 로봇과 물체와의 거리를 판단하여 로봇의 움직임을 제어하는데 사용한다. 초음파와 적외선 센서는 물체의 유무와 물체의 대략의 거리를 예측하는 1차 센서로 사용되며 거리 계산결과와 실제 거리 값과의 오차는 5%이내이다. 영상처리에 의해 2차의 섬세한 물체 검출 및 추적을 수행하여 최종적으로 센서 융합에 의한 물체 검출율을 개선하였다. 영상처리방법은 물체와 배경 및 유사잡음들과의 강인한 분리를 위하여 고유색상정보와 움직임 정보 등의 사전정보를 활용하였으며, 형태의 변화가 수반되는 경우에도 유연한 대처능력을 갖도록 하기 위해 시그니처를 이용한 영역분할 방법을 통해 모든 후보영역내의 물체의 존재를 확인하고 목표 물체영역만을 검출하였다. 세가지 센서에 의한 대상 물체 검출 결과의 합은 최종적인 검출을 결정하는데 확률적 근거로 활용되며 각 개별 센서를 사용한 경우보다 최소 7% 이상의 검출율이 개선되었다.

연안 해양기상(해상풍, 수온) 관측을 위한 항공기 원격탐사 시스템 (Development of Airborne Remote Sensing System for Monitoring Marine Meteorology (Sea Surface Wind and Temperature))

  • 김덕진;조양기;강기묵;김진우;김승희
    • 한국해양학회지:바다
    • /
    • 제18권1호
    • /
    • pp.32-39
    • /
    • 2013
  • 인공위성은 넓은 지역에 대한 전 세계의 정보를 획득하는데 유용하지만, 좁은 지역에 대한 적시적소에 촬영하는 데는 한계가 있다. 이러한 단점을 극복하기 위하여 본 연구에서는 항공기 원격탐사 시스템을 구축하였다. 항공기 원격탐사시스템은 SAR센서와 열적외선 센서로 구성되어 있으며, 획득된 자료의 방사 및 기사보정을 위하여 GPS, IMU, 온도/습도계 등도 설치하였다. SAR영상은 표면 거칠기에 따라 민감하게 반응하여 밝기 값이 달라지게 되며, 해양에서는 바람에 의해 쉽게 생성 되는 표면 장력파의 진폭이 이러한 표면 거칠기를 야기한다. 따라서 정량화된 SAR의 후방산란과 해상풍 사이의 관계식을 통해 해상풍 추출이 가능하다. 한편, 열적외선 센서는 물체의 온도를 측정하는데 유용하며, 물체와 센서 사이의 대기에 의한 효과를 보정한 후 수온 추출이 이루어진다. 이 두 센서를 탑재한 항공기로 서해안 일대를 4차례 시험비행을 수행하였으며, 이로부터 획득된 SAR 및 열적외선 영상의 품질이 연안환경 모니터링 및 해양기상 자료 추출에 충분함을 보여주었다.

적외선 검출기 검보정을 위한 대구경흑체 설계, 제작 및 검증 (Full Aperture Black Body Design, Fabrication and Validation for Infrared Detector Calibration)

  • 조혁진;서희준;김근식;박성욱;문귀원
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.40-45
    • /
    • 2013
  • 적외선 영상을 획득하는 인공위성의 적외선 검출기는 임무 궤도에서 정확한 성능을 보장받기 위해 발사 전 지상에서 흑체를 이용한 검보정 환경시험을 거쳐야 한다. 적외선 탑 재체의 검보정 기준이 되는 대구경흑체는 궤도환경 지상시험을 위해 진공환경에 적합한 재질로 구성되어야 하며, $-40^{\circ}C$에서 $+40^{\circ}C$까지의 온도 범위에서 중심 80 %의 영역에 대해 $2^{\circ}C$ 이하의 표면 온도 균일도와 0.95 이상의 방사율을 가져야 한다. 열유동해석 결과로 도출된 대구경흑체는 $1m{\times}1m{\times}8mm$의 크기의 구리판에 방사율을 높이기 위한 알루미늄 하니콤 코아를 부착하고, 블랙페인트를 도포하여 제작되었으며, 온도 조절을 위해 뒷면에는 질소가스 흐름을 위한 구리튜브가 용접되었다. 한국항공우주연구원의 광학열 진공챔버에서 수행된 대구경흑체 검증시험에서 20개의 저항온도센서와 적외선카메라를 이용하여 표면 온도 분포를 측정하여 ${\pm}40^{\circ}C$의 온도 범위에서 약 $1^{\circ}C$의 온도 균일도를 가짐을 확인하였다. 표면방사율은 대기압, $40^{\circ}C$에서 0.975로 측정되었다.

p-i-n 구조의 InSb 웨이퍼를 이용한 적외선 광다이오드의 제조 및 그 특성 (Fabrication and Characteristics of Infrared Photodiode Using Insb Wafer with p-i-n Structure)

  • 조준영;김종석;손승현;이종현;최시영
    • 센서학회지
    • /
    • 제8권3호
    • /
    • pp.239-246
    • /
    • 1999
  • MOCVD로 성장된 p-i-n 구조의 InSb 웨이퍼를 이용하여 $3{\sim}5\;{\mu}m$ 영역의 적외선을 감지할 수 는 고감도 광기전력 형태의 적외선 광다이오드를 제조하였다. InSb는 녹는점과 표면원자들의 증발온도가 낮기 때문에 광다이오드의 접합계면과 표면의 절연보호막으로 $SiO_2$ 박막을 원격 PECVD를 이용하여 성장시켰다. 광다이오드의 저항성 접촉을 위해 In을 증착하였고 77K의 암상태에서 전류-전압 특성을 조사하였다. 영전위 저항과 수광면적의 적($R_0A$)이 $1.56{\times}10^6\;{\Omega}{\cdot}cm^2$의 높은 값을 가졌는데 이는 BLIP 조건을 만족하는 높은 값이었다. InSb 광다이오드에 적외선을 입사 했을때 $10^{11}\;cm{\cdot}Hz^{1/2}{\cdot}W^{-1}$의 매우 높은 정규화된 검지도를 나타내었다. 높은 양자효율과 검지도로 인해 제조된 InSb 적외선 단위 셀을 적외선 array에 그 적용이 가능할 것으로 보인다.

  • PDF