• Title/Summary/Keyword: infrared imaging camera

Search Result 142, Processing Time 0.026 seconds

AKARI INFRARED CAMERA SURVEY OF THE LARGE MAGELLANIC CLOUD

  • Shimonishi, T.;Kato, D.;Ita, Y.;Onaka, T.;AKARI/IRC LMC team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.83-85
    • /
    • 2017
  • We conducted an unbiased near- to mid-infrared imaging and spectroscopic survey of the Large Magellanic Cloud (LMC) as a part of the AKARI Mission Program "Large-area Survey of the LMC" (LSLMC, PI: T. Onaka). An area of about 10 square degrees of the LMC was observed by five photometric bands (3.2, 7, 11, 15, and $24{\mu}m$) and a low-resolution slitless prism ($2-5{\mu}m$, R ~20) equipped with AKARI /IRC. We constructed and publicly released photometric and spectroscopic catalogues of point sources in the LMC based on the survey data. The catalogues provide a large number of near-infrared spectral data, coupled with complementary broadband photometric data. Combined use of the present AKARI LSLMC catalogues with other infrared point source catalogues of the LMC possesses scientific potential that can be applied to various astronomical studies.

A Study on the Best Applicationsof Infra-Red(IR) Sensors Mounted on the Unmanned Aerial Vehicles(UAV) in Agricultural Crops Field (무인기 탑재 열화상(IR) 센서의 농작물 대상 최적 활용 방안 연구)

  • Ho-Woong Shon;Tae-Hoon Kim;Hee-Woo Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1073-1082
    • /
    • 2023
  • Thermal sensors, also called thermal infrared wavelength sensors, measure temperature based on the intensity of infrared signals that reach the sensor. The infrared signals recognized by the sensor include infrared wavelength(0.7~3.0㎛) and radiant infrared wavelength(3.0~100㎛). Infrared(IR) wavelengths are divided into five bands: near infrared(NIR), shortwave infrared(SWIR), midwave infrared(MWIR), longwave infrared(LWIR), and far infrared(FIR). Most thermal sensors use the LWIR to capture images. Thermal sensors measure the temperature of the target in a non-contact manner, and the data can be affected by the sensor's viewing angle between the target and the sensor, the amount of atmospheric water vapor (humidity), air temperature, and ground conditions. In this study, the characteristics of three thermal imaging sensor models that are widely used for observation using unmanned aerial vehicles were evaluated, and the optimal application field was determined.

Design and Analysis of Coaxial Optical System for Improvement of Image Fusion of Visible and Far-infrared Dual Cameras (가시광선과 원적외선 듀얼카메라의 영상 정합도 향상을 위한 동축광학계 설계 및 분석)

  • Kyu Lee Kang;Young Il Kim;Byeong Soo Son;Jin Yeong Park
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.106-116
    • /
    • 2023
  • In this paper, we designed a coaxial dual camera incorporating two optical systems-one for the visible rays and the other for far-infrared ones-with the aim of capturing images in both wavelength ranges. The far-infrared system, which uses an uncooled detector, has a sensor array of 640×480 pixels. The visible ray system has 1,945×1,097 pixels. The coaxial dual optical system was designed using a hot mirror beam splitter to minimize heat transfer caused by infrared rays in the visible ray optical system. The optimization process revealed that the final version of the dual camera system reached more than 90% of the fusion performance between two separate images from dual systems. Multiple rigorous testing processes confirmed that the coaxial dual camera we designed demonstrates meaningful design efficiency and improved image conformity degree compared to existing dual cameras.

Soundness Evaluation of 120W LED Lighting using Passive Infrared Thermal Imaging Method (수동적 적외선 열화상 기법을 적용한 120W급 LED조명등 건전성 평가)

  • Jung, Yoon-Soo;Gao, Jia-Chen;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.140-146
    • /
    • 2017
  • As energy conservation and environmental issues are emerging as a hot topic around the world, consumers are demanding high-efficiency, eco-friendly products. In this study, the author proposed 120W LED lighting system that replace metal halide lamp (MHL) which is currently used in the industry. Furthermore, it would be possible to provide a perfect opportunity for Korea to rise as a global leader in the LED lighting industry through soundness evaluation of the LED lighting system that is applied.

Optical Design of a Snapshot Nonmydriatic Fundus-imaging Spectrometer Based on the Eye Model

  • Zhao, Xuehui;Chang, Jun;Zhang, Wenchao;Wang, Dajiang;Chen, Weilin;Cao, Jiajing
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.151-160
    • /
    • 2022
  • Fundus images can reflect ocular diseases and systemic diseases such as glaucoma, diabetes mellitus, and hypertension. Thus, research on fundus-detection equipment is of great importance. The fundus camera has been widely used as a kind of noninvasive detection equipment. Most existing devices can only obtain two-dimensional (2D) retinal-image information, yet the fundus of the human eye also has spectral characteristics. The fundus has many pigments, and their different distributions in the eye lead to dissimilar tissue penetration for light waves, which can reflect the corresponding fundus structure. To obtain more abundant information and improve the detection level of equipment, a snapshot nonmydriatic fundus imaging spectral system, including fundus-imaging spectrometer and illumination system, is studied in this paper. The system uses a microlens array to realize snapshot technology; information can be obtained from only a single exposure. The system does not need to dilate the pupil. Hence, the operation is simple, which reduces its influence on the detected object. The system works in the visible and near-infrared bands (550-800 nm), with a volume less than 400 mm × 120 mm × 75 mm and a spectral resolution better than 6 nm.

The Near-Infrared Imaging Spectroscopy to Visualize the Distribution of Sugar Content in the Flesh of a Melon

  • Tsuta, Mizuki;Sugiyama, Junichi;Sagara, Yasuyuki
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1526-1526
    • /
    • 2001
  • To improve the accuracy of sweetness sensor in automated sorting operations, it is necessary to clarify unevenness of the sugar content distribution within fruits. And it is expected that the technique to evaluate the content distribution in fruits contribute to the development of the near-infrared (NIR) imaging spectroscopy. Sugiyama (1999) had succeeded to visualize the distribution of the sugar content on the surface of a half-cut green fresh melon. However, this method cannot be applied to red flesh melons because it depends on information of the absorption band of chlorophyll (676 nm), which is affected by the color of the fresh. The objective of this study was to develop the universal visualization method depends on the absorption band of sugar, which can be applied to various kinds of melons and other fruits. The relationship between the sugar contents and absorption spectra of both green and red fresh melons were investigated by using a NIR spectrometer to determine the absorption band of sugar. The combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm was highly correlated with the sugar contents. The wavelength of 902 nm is attributed to the absorption band of sugar. A cooled charge-coupled device (CCD) imaging camera which has 16 bit (65536 steps) A/D resolution was equipped with rotating band-pass filter wheel and used to capture the spectral absorption images of the flesh of a vertically half-cut red fresh melon. The advantage of the high A/D resolution in this research is that each pixel of the CCD is expected to function as a detector of the NIR spectrometer for quantitative analysis. Images at 846 nm, 874 nm, 902 nm and 930 nm were acquired using this CCD camera. Then the 2$\^$nd/ derivative absorbances at 902 nm and 874 nm at each pixel were calculated using these four images. On the other hand, parts of the same melon were extracted for capturing the images and squeezed for the measurement of sugar content. Then the calibration curve between the combination of 2$\^$nd/ derivative absorbances at 902 nm and 874 nm and sugar content was developed. The calibration method based on NIR spectroscopy techniques was applied to each pixel of the images to convert the 2$\^$nd/ derivative absorbances into the Brix sugar content. Mapping the sugar content value of each pixel with linear color scale, the distribution of the sugar content was visualized. As a result of the visualization, it was quantitatively confirmed that the Brix sugar contents are low at the near of the skin and become higher towards the seeds. This result suggests that the visualization technique by the NIR imaging spectroscopy could become a new useful method fer quality evaluation of melons.

  • PDF

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

FABRICATION AND ALIGNMENT OF PARTS OF THE KASINICS OFFNER SYSTEM (KASINICS 오프닝 광학계의 부품 가공 및 정렬)

  • Mok, Seung-Won;Lee, Sung-Ho;Yuk, In-Soo;Park, Young-Sik;Jin, Ho;Han, Jeong-Yeo;Moon, Bong-Kon;Cha, Sang-Mok;Kim, Geon-Hee;Im, Myung-Shin
    • Publications of The Korean Astronomical Society
    • /
    • v.21 no.2
    • /
    • pp.43-49
    • /
    • 2006
  • The KASINICS (KASI Near Infrared Camera System) is a ground-based Near-Infrared (NIR) imaging instrument developed by the Korea Astronomy and Space Science Institute (KASI). In this paper, we report the test results of the KASINICS camera optics system which is comprised of a 1-1 Offner relay. We measure that the surface RMS fluctuations of the Offner mirrors are at the level of $10^{-1}-10^{-2}$ of the target wavelengths, showing that the mirrors are sufficiently smooth for NIR observations. The alignment of the Offner optics system has been checked too. Our ray-tracing simulations find that the image quality should not degrade more than the pixel size of the KASINICS ($40{\mu}m$), if a de-centering or a tilt of the Offner mirrors are within 5mm, or $2.5^{\circ}$. Our measurement shows that the de-centering or the tilt of the Offner mirrors are less than 1 mm or $0.5^{\circ}$, assuring that the KASINICS image quality are not affected by the alignment errors. We have also measured that the optics resolution is $20{\mu}m$ and it does not degrade more than 10% over the detector surface area of 14.3 mm ${/times}$ 14.3mm. Overall, we conclude that the KASINICS optics system satisfies the design requirements for NIR imaging observations.

A Study on the Improvement of Image Quality for a Thermal Imaging System with focal Plane Array Typed Sensor (초점면 배열 방식 열상 카메라 시스템의 화질 개선 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • Thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main Part of the system is thermal camera in which a focal plane array typed sensor is introduced The sensor detects mid-range infrared spectrum or target objects and then it output generic video signal which should be processed to form a thermal image frame. A digital signal processor(DSP) in the system inputs analog to digital converted data. performs algorithms to improve the thermal images and then outputs the corrected frame data to frame buffers for NTSC encoding and for digital outputs.. To enhance the quality of the thermal images, two point correction method is applied. Figures indicate that the corrected thermal images are much improved.

  • PDF

Development of the Ultra Precision Thermal Imaging Optical System (초정밀 열 영상 현미경 광학계 개발)

  • Yang, Sun-Choel;Won, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.