• 제목/요약/키워드: infrared image analysis

검색결과 249건 처리시간 0.029초

연속발진 레이저에 의한 CCD 영상센서의 손상 분석 (Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser)

  • 윤성희;장경영;신완순
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.

적외선 열화상 카메라용 캘리브레이션 타겟 개발 (Development of Calibration Target for Infrared Thermal Imaging Camera)

  • 김수언;최만용;박정학;신광용;이의철
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.248-253
    • /
    • 2014
  • 카메라 영상 캘리브레이션은 머신비전과 같은 비전검사기술분야에서 영상으로부터 기하학적 정보를 정확하게 추출하고자 할 때 정확성을 높이는데 필요한 매우 중요한 과정이다. 그러나 기존에 가시광 카메라에 사용되던 캘리브레이션 타겟은 중적외선, 원적외선 열화상 카메라에 적용하기 어렵다. 최근에 적외선 열화상카메라를 이용한 결함측정기술이 많이 사용되면서 적용할 수 있는 캘리브레이션 타겟 개발이 요구되고 있다. 따라서 본고에서는 유한요소 열전달 해석을 이용하여 가시광 카메라와 적외선 열화상카메라 모두에 적용 가능한 캘리브레이션 타겟을 제안하였다. 개발된 캘리브레이션 타겟을 열화상카메라와 가시광 카메라로 촬영하여 비교실험 하였으며, 실험결과 제안된 캘리브레이션 타겟의 효율성을 보여준다.

온배수 확산분석을 위한 Remote Sensing 활용에 관한 연구 (A Study on Application of Remote Sensing for Thermal Plume Analysis)

  • 유복모;조기성
    • 대한공간정보학회지
    • /
    • 제1권2호
    • /
    • pp.185-194
    • /
    • 1993
  • 원격탐측은 초기에는 자연현상이나 지표대상물의 개략적인 분포와 변화를 추출하는데 사용되어 왔으나 최근에는 식물의 분광특성을 이용한 농업조사, 산림조사나 지하자원탐사, 해양상의 수온 및 해류분포조사, 기상조사 등 많은 분야에 응용되고 있다. 본 연구에서는 이와 같은 원격탐측의 많은 응용분야 중에서 해양으로 배출되는 공장온배수의 확산범위를 조사하기 위하여 지구자원 탐사위성인 LANDSAT-5호에 탑재되어 있는 TM에 의해 얻어진 영상과 지상탐측기인 열적외주사기 Thermo Tracer에 의해 얻어진 열적외 영상을 이용하였다. LANDSAT TM영상의 Band 6은 열적외 Band로서 NASA의 CSFC에서 제공한 변환식 및 사후검정값을 이용하여 Band 6의 gray level값으로부터 해수온도 분포를 추출하였으며, Thermo Tracer의 열적외 영상은 TH1100 Series의 Processing mode를 이용하여 온도분포를 얻었다. 이와 같은 영상을 분석한 결과 근해의 수심이 얕은 지역의 해수온도는 담수온도와 내륙온도의 영향을 크게 받고 있음을 알 수 있었으며, 온배수의 확산범위 및 면적을 시각적 및 정량적으로 나타낼 수 있었다. 또한 열적외선 주사영상을 이용하여 보다 세부적인 확산범위를 제시할 수 있었으며 LANDSAT영상결과와 거의 동일한 결과를 나타냄을 알 수 있다.

  • PDF

열적외선 영상분석을 이용한 기능성 스포츠 팬티 개발 (Developing of Functional Sport Underpants using Infrared Thermal Image Analysis)

  • 이중숙;양정옥;이범진
    • 한국운동역학회지
    • /
    • 제25권2호
    • /
    • pp.231-240
    • /
    • 2015
  • Objective : This study is for providing data about men's functional sport underpants. It provides the fundamental data of biomechanics by measuring and analyzing the functionality of various underpants using infrared thermal image camera. Method : Then author drew a conclusion based on the final analysis of 965 questionnaire survey results about issues on men's functional sport underpants after discarding invalid questionnaires, as following. Change in body temperature while wearing functional underpants compared to general briefs or boxer pants showed lower temperature by approximately 1~2 degrees Celsius. In the case of general underpants, wearer sweats and feels hotter due to the friction of penis, scrotum and thigh. However functional sport functional underpants improved this issue with ergonomic 3D design by putting penis towards the lower part of the abdomen(below the navel) while putting the scrotum comfortably on the testicles, which enables to make room between the penis, scrotum and thigh of a wearer. Results : This was analyzed to lower the temperature of penis and scrotum. The survey results about the quality of functional underpants showed that 78% of the respondents felt comfortable while driving; 68.5% replied that frictional heat decreased while working out; 78.7% felt less sweat and humidity; 81.7% replied as highly wearable and comfortable; 77.1% replied functional sport underpants were the most comfortable in routine lives or in workout times. Putting all such results together, it is possible to conclude that functional sport is an excellent product. Conclusion : This can be evaluated as an excellent functional sport underpants, towards the penis abdomen (under the navel) in 3D human engineering design, by the scrotum to wearing to be easier to scrotum of pocket, the penis and scrotum and thighs were separated and analyzed with a function that will lower the body temperature of the penis and scrotum.

표면온도분포 분석을 이용한 몰드 변압기 진단 (Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution)

  • 임용배;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

시판 발열의복의 발열성능 평가 (Evaluation for the Heating Performance of the Heated Clothing on Market)

  • 이현영;정연희
    • 한국의류산업학회지
    • /
    • 제12권6호
    • /
    • pp.843-850
    • /
    • 2010
  • To evaluate the heating performance of commercial heated vests, we investigated the thermal images and the temperature between body and vest for three heated vests. We captured infrared thermography by FT-IR Spectrometer to analyzed the heating temperature of the heating elements taken from the vests, and the maximum heating temperature of the vests was compared with thermal image in the room temperature($18^{\circ}C$). In outdoor experiment($-4.7^{\circ}C$), we measured the inner temperature as well as the thermal image of heated vests. Four healthy men participated in this experiment, and the ANOVA and Duncan test was performed for statistical analysis. As the results, the heating temperature range of the heated vests used in this experiment was $32{\sim}42^{\circ}C$, much lower than the displayed temperature range in their specifications, so the exact specification for heating performance of heated clothing was required. In comparisons of the heating performance among the heated vests, we found out that the insulation of clothing is very important to design the heated clothing, because the inner temperature of the vest had good insulation by itself was higher than that of the vest shown higher temperature over $7^{\circ}$ than another vests at the heating temperature.

로봇 착유시스템을 위한 NIR 필터 선정 및 유두인식 영상처리 (Image Processing for Recognition of Cow Teats and Selection of a NIR Filter for Robot Milking System)

  • 김웅;이대원
    • Journal of Biosystems Engineering
    • /
    • 제30권5호
    • /
    • pp.299-305
    • /
    • 2005
  • This study was developed image processing algorithm for recognition of few teats of a cow in the image using black and white camera attached with infrared filter. Spectroscopic analysis was used for selection of a NIR filter to separate teats from udder skin in the image captured. To verify the performance of image processing algorithm was developed and NIR filter was selected, carried out an experiment with cows. NIR band-pass filter was used to pass the 975nm band of light spectrum. The image processing algorithm was developed could recognize all teats and the process time was 0.9 second to recognize the all teats and to acquire end position of teats.

Detecting Incipient Caries Using Front-illuminated Infrared Light Scattering Imaging

  • Kim, Ji-Young;Ro, Jung-Hoon;Jeon, Gye-Rok;Kim, Jin-Bom;Ye, Soo-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.310-316
    • /
    • 2012
  • A new method for early caries diagnosis was proposed and tested through a home-made optical examination system that used quantitative light fluorescence (QLF) and digital imaging fiber optic transillumination (FOTI) (DIFOTI), with light sources across a wide spectral range, from 350 nm to 1,000 nm. The front-illuminated infrared light scattering image (FIR) showed similar diagnostic abilities to that of DIFOTI. The FIR method was invented based on the observation that caries lesions lose the high transmittance and low scattering properties of benign enamel tissue. There are various methods for the early diagnosis of caries, such as visual examination, exploration, X-ray radiography, QLF, FOTI, and infrared fluorescence (diagnodent). Among them, methods based on optical properties are regarded as having the most potential. A comparative study was performed between the FOTI, QLF, diagnodent, optical coherence tomography, and FIR scattering image methods, using 20 extracted teeth samples with early caries. A scale of lesion measurement based on optical image contrast was proposed. The statistical analysis showed a significant correlation between the DIFOTI and FIR methods (r = 0.35, p < 0.05). However, the QLF and diagnodent methods showed little association with FIR images, as they have different detection principles as compared with FIR. Tomographic images obtained by OCT, using 1,330 nm super luminescent LED as a gold standard of tooth structure, verified that the FOTI and FIR results correctly represented the lack of homogeneity in dental tissue. The newly proposed FIR method attained similar diagnostic results to those of FOTI, but with an easier approach.

적외선 카메라-레이저 공통광학계의 레이저빔 열 영향성 분석 (Analysis of Laser-beam Thermal Effects In an Infrared Camera and Laser Common-path Optical System)

  • 김성재
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2017
  • 지향성적외선방해장비의 정렬 정밀도를 높히고 중량을 감소시키기 위해 적용된 적외선 카메라-레이저 공통광학계 구조에서 영상 성능 저하를 야기시키는 레이저빔 열 영향성을 분석하였다. 높은 에너지 밀도를 가지는 레이저빔이 광부품에 흡수되면 열이 발생하고 온도가 상승한다. 공통광학계 광부품 표면에서 발생한 열은 시스템 투과율을 감소시켜 적외선 카메라의 영상 품질을 저하시킬 수 있다. 지향성적외선방해장비의 운용개념을 고려하여 파장 $4{\mu}m$, 출력 3 W의 레이저빔이 10초간 미러(알루미늄, 실리카 글래스, 실리콘) 및 렌즈(사파이어, 셀레늄화아연, 실리콘, 게르마늄) 재료에 조사되는 상황을 가정하여 온도 분포를 계산하였다. 계산 결과, 미러 재료로는 실리카 글래스, 렌즈 재료로는 사파이어의 온도 상승이 상대적으로 컸고, 재료 온도 분포에 가장 큰 영향을 미치는 요소는 재료의 레이저빔 흡수율과 열전도도임을 확인하였다. 결론적으로 적외선 카메라-레이저 공통광학계에 사용하는 광부품은 흡수율이 낮고 열전도도가 높은 특성을 갖도록 선정되어야 광부품 온도 상승에 의한 적외선 카메라의 영상 품질 저하를 방지할 수 있다.

An Extraction of Solar-contaminated Energy Part from MODIS Middle Infrared Channel Measurement to Detect Forest Fires

  • Park, Wook;Park, Sung-Hwan;Jung, Hyung-Sup;Won, Joong-Sun
    • 대한원격탐사학회지
    • /
    • 제35권1호
    • /
    • pp.39-55
    • /
    • 2019
  • In this study, we have proposed an improved method to detect forest fires by correcting the reflected signals of day images using the middle-wavelength infrared (MWIR) channel. The proposed method is allowed to remove the reflected signals only using the image itself without an existing data source such as a land-cover map or atmospheric data. It includes the processing steps for calculating a solar-reflected signal such as 1) a simple correction model of the atmospheric transmittance for the MWIR channel and 2) calculating the image-based reflectance. We tested the performance of the method using the MODIS product. When compared to the conventional MODIS fire detection algorithm (MOD14 collection 6), the total number of detected fires was improved by approximately 17%. Most of all, the detection of fires improved by approximately 30% in the high reflection areas of the images. Moreover, the false alarm caused by artificial objects was clearly reduced and a confidence level analysis of the undetected fires showed that the proposed method had much better performance. The proposed method would be applicable to most satellite sensors with MWIR and thermal infrared channels. Especially for geostationary satellites such as GOES-R, HIMAWARI-8/9 and GeoKompsat-2A, the short acquisition time would greatly improve the performance of the proposed fire detection algorithm because reflected signals in the geostationary satellite images frequently vary according to solar zenith angle.