• Title/Summary/Keyword: infrared detector

Search Result 320, Processing Time 0.022 seconds

INFRARED PHOTOMETRIC STUDY OF FIELD POPULATION II STARS

  • LEE SANG-GAK;BRUCE W. CARNEY;ROBERT PROBST
    • Journal of The Korean Astronomical Society
    • /
    • v.30 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Near infrared JHK magnitudes are presented for two hundred two high proper motion stars. We have observed high proper motion stars in the near-infrared bands(JHK) using the COB detector on the Kitt Peak 1.3m, 2.1m and 4m telescopes. The observations and data reduction procedures are described. The infrared color magnitude diagram and color-color diagrams for the program stars are presented.

  • PDF

Design and analysis of a signal readout integrated circuit for the bolometer type infrared detect sensors (볼로미터형 적외선 센서의 신호처리회로 설계 및 특성)

  • Kim, Jin-Su;Park, Min-Young;Noh, Ho-Seob;Lee, Seoung-Hoon;Lee, Je-Won;Moon, Sung-Wook;Song, Han-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.475-483
    • /
    • 2007
  • This paper proposes a readout integrated circuit (ROIC) for $32{\times}32$ infrared focal plane array (IRFPA) detector, which consist of reference resistor, detector resistor, reset switch, integrated capacitor and operational amplifier. Proposed ROIC is designed using $0.35{\;}{\mu}m$ 2P-4M (double poly four metal) n-well CMOS process parameters. Low noise folded cascode operational amplifier which is a key element in the ROIC showed 12.8 MHz unity-gain bandwidth and open-gain 89 dB, phase margin $67^{\circ}$, SNR 82 dB. From proposed circuit, we gained output voltage variation ${\Delta}17{\};mV/^{\circ}C$ when the detector resistor varied according to the temperature.

Fabrication of 3D Feed Horn IR Antenna for IR Detector

  • Kim, Kun-Tae;Han, Yong-Hee;Shin, Hyun-Joon;Sung Moon;Park, Jung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.170-175
    • /
    • 2004
  • A three dimensional feed horn 10${\mu}{\textrm}{m}$ wavelength infrared antenna has been suggested, fabricated and characterized. It was applied to an infrared detector for efficient collecting of IR radiation and for reducing background noise. The horn antenna size was designed for maximum antenna directivity. The 3D feed horn antenna mold was fabricated using rotating and tilted illumination while the antenna plate was constructed by way of electroplating. Antenna characteristics were measured by coupling with a microbolometer. Measurement results indicated that the directivity of the antenna is 16.1㏈ and the background noise is reduced by approximately two times.

Thermal Analysis of a Cryochamber for an Infrared Detector Considering a Radiation Shield (적외선 검출기용 극저온 챔버에서 복사 차폐막을 고려한 열해석)

  • Kim Young-Min;Kang Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.672-677
    • /
    • 2006
  • The steady cooling characteristics of a cryochamber for infrared (IR) detector have been investigated analytically, considering radiation shields. The thermal modeling considers the conduction heat transfer through cold finger, the gaseous conduction due to out-gassing, and the radiation heat transfer. The cooling load of the cryochamber is obtained by using a fin equation. The results obtained indicate that the gaseous conduction plays an important role in determining the steady cooling load. The steady cooling load is increased as the gas pressure is increased. It is also found that the cooling load is substantially decreased with a radiation shield. The most thermal load of a cryochamber occurs through the cold finger.

Fabrication of 64x1 linear array infrared detector using Hg1-xCdxTe (Hg1-xCdxTe를 이용한 64x1 선형 적외선 감지 소자 제작)

  • Kim, Jin-Sang;Suh, Sang-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.135-138
    • /
    • 2009
  • $64{\times}1$ forcal plane infrared detector has been fabricated by using HgCdTe epi layer. HgCdTe was grown on GaAs substrate by using metal organic chemical vapor deposition. This paper describes key developments in the epi layer growth and device fabrication process. The performance of IR imaging system is summarized.

Near-Infrared Light Propagation in an Adult Head Model with Refractive Index Mismatch

  • Kim, Seung-Hwan;Lee, Jae-Hoon
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • We investigate near-infrared light (NIR) propagation in a model of an adult head using an extensive Monte Carlo (MC) simulation. The adult head model is a four-layered slab which consists of a surface layer, a cerebrospinal fluid layer, a gray-matter layer, and a white-matter layer. We study the effects of a refractive index mismatch on the model, calculating the intensity of detected light, mean flight time, and partial mean flight time of each layer for various refractive indices of the cerebrospinal fluid layer as functions of source-detector spacing. The Monte Carlo simulation shows that the refractive index mismatch presents very rich results including rapidly decaying intensity of detected light and a peak and cross-over in the partial mean flight time with source-detector spacing. We also investigate spatial sensitivity profiles at various source-detector spacings, discussing the index mismatch effect on the model.

  • PDF

Wide-angle optical design using high-resolution uncooled thermal detector

  • Lee, Jonghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.11
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we propose efficient design and construction of an infrared wide angle optical system with low distortion utilizing a high resolution detector for automobile application. The operational convenience and the recognition ability have been improved significantly by applying the high resolution uncooled thermal detector with wide angle optical design. The active ahtermalization mechanism is implemented so that the adjustment of the optical component of the system is to be made automatically according to the temperature change by motorized control. The modulation transfer function (MTF) is about 50% at the Nyquist frequency close the diffraction limit. The distortion is less than 5% at the edge field. As a result, a high-resolution uncooled thermal optical system with wide field of view (FOV) is assembled, aligned and its performance is tested successfully.

Adaptive Nonlinear Filter for Removal of Salt-Pepper Noise in Infrared Image (적외선 영상의 Salt-Pepper 잡음제거를 위한 적응 비선형 필터)

  • Lee, Je-Il;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.9
    • /
    • pp.429-434
    • /
    • 2006
  • In this paper, detection based - adaptive windowed nonlinear filter(DB-AWNF) is proposed for removing salt-pepper noise in infrared image. This filter is composed of impulse detector and window-size-variable median filters. Impulse detector checks whether current pixel is impulse or not using range function and nonlinear location estimator. If impulse is detected, current pixel is filtered according to four kinds of local masks by use of median filter. If not, current pixel is delivered to output like identity filter. In Qualitative view, the proposed could have removed heavy corrupted noise up to 30% and reserved the details of image. In quantitative view, PSNR was measured. The proposed could have about 12-31[dB] more improved performance than those of median $(3{\times}3)$ filter and 13-29[dB] more improved performance than those of median $(5{\times}5)$ filter.

High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector (320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현)

  • Hong, Seok-Min;Yu, Wee-Kyung;Yoon, Eun-Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

Experimental Study on the Stirling refrigerator for Cooling of Infrared Detector (적외선 센서 냉각용 스터링 냉동기의 실험적 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Koh, D.Y.;Kim, J.H.;Yu, B.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.172-176
    • /
    • 2001
  • A Stirling cryocooler is relatively compact, reliable, commercially available, and uses helium as a working fluid. The FPFD stirling cryocooler consists of two compressor pistons driven by linear motors which makes pressure waves and a pneumatically driven displacer piston with regenerator. A free piston and free displacer(FPFD) Stirling cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM(Korea Institute of Machinery & Materials). In order to evaluate the feasibility of using a linear motor driving cryocooler, prototype Stirling cryocooler with a nominal cooling capacity of 0.5W at 80K was designed, fabricated and tested. The prototype has achieved no load temperature of 51K and cooling power of 0.33W.

  • PDF