• 제목/요약/키워드: infrared Image

검색결과 906건 처리시간 0.026초

지평선을 이용한 영상기반 위치 추정 방법 및 위치 추정 오차 (A Vision-based Position Estimation Method Using a Horizon)

  • 신종진;남화진;김병주
    • 한국군사과학기술학회지
    • /
    • 제15권2호
    • /
    • pp.169-176
    • /
    • 2012
  • GPS(Global Positioning System) is widely used for the position estimation of an aerial vehicle. However, GPS may not be available due to hostile jamming or strategic reasons. A vision-based position estimation method can be effective if GPS does not work properly. In mountainous areas without any man-made landmark, a horizon is a good feature for estimating the position of an aerial vehicle. In this paper, we present a new method to estimate the position of the aerial vehicle equipped with a forward-looking infrared camera. It is assumed that INS(Inertial Navigation System) provides the attitudes of an aerial vehicle and a camera. The horizon extracted from an infrared image is compared with horizon models generated from DEM(Digital Elevation Map). Because of a narrow field of view of the camera, two images with a different camera view are utilized to estimate a position. The algorithm is tested using real infrared images acquired on the ground. The experimental results show that the method can be used for estimating the position of an aerial vehicle.

Characterisation of Tensile Deformation through Infrared Imaging Technique

  • B. Venkataraman, Baldev Raj;Mukhophadyay, C.K.
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.609-620
    • /
    • 2002
  • It is well known that during tensile testing, a part of the mechanical work done on the specimen is transformed into heat energy. However, the ultimate temperature rise and the rate of temperature rise is related to the nature of the material, conditions of the test and also to the deformation behaviour of the material during loading. The recent advances in infrared sensors and image/data processing techniques enable observation and quantitative analysis of the heat energy dissipated during such tensile tests. In this study, infrared imaging technique has been used to characterise the tensile deformation in AISI type 316 nuclear grade stainless steel. Apart from identifying the different stages during tensile deformation, the technique provided an accurate full-field temperature image by which the point and time of strain localization could be identified. The technique makes it possible to visualise the region of deformation and failure and also predict the exact region of fracture in advance. The effect of thermal gradients on plastic flow in the case of interrupted straining revealed that the interruption of strain and restraining at a lower strain rate not only delays the growth of the temperature gradient, but the temperature rise per unit strain decreases. The technique is a potential NDE tool that can be used for on-line detection of thermal gradients developed during extrusion and metal forming process which can be used for ensuring uniform distribution of plastic strain.

UV/IR센서 결합에 의한 불꽃 영상검출의 설계 및 분석 (Design and Analysis of Flame Signal Detection with the Combination of UV/IR Sensors)

  • 강대석;김은종;문필재;신원호;강민구
    • 인터넷정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.45-51
    • /
    • 2013
  • 본 논문에서는 자외선(UV, ultraviolet) 및 적외선(IR, infrared) 센서를 결합함으로서 불이 연소하면서 방출하는 빛의 파장을 활용한 영상신호를 검출하는 결합형 불꽃영상 검출시스템은 적외선 센서와 자외선 센서 기반의 신호처리 알고리즘 설계방안을 제안한다. 또한, 설계한 듀얼모드인 결합형 불꽃영상 검출시스템은 단독형 적외선 또는 자외선 센서 기반의 영상검출 알고리즘의 검출 성능결과를 비교한다.

연속발진 레이저에 의한 CCD 영상센서의 손상 분석 (Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser)

  • 윤성희;장경영;신완순
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.

FPGA-Based Real-Time Multi-Scale Infrared Target Detection on Sky Background

  • Kim, Hun-Ki;Jang, Kyung-Hyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.31-38
    • /
    • 2016
  • In this paper, we propose multi-scale infrared target detection algorithm with varied filter size using integral image. Filter based target detection is widely used for small target detection, but it doesn't suit for large target detection depending on the filter size. When there are multi-scale targets on the sky background, detection filter with small filter size can not detect the whole shape of the large targe. In contrast, detection filter with large filter size doesn't suit for small target detection, but also it requires a large amount of processing time. The proposed algorithm integrates the filtering results of varied filter size for the detection of small and large targets. The proposed algorithm has good performance for both small and large target detection. Furthermore, the proposed algorithm requires a less processing time, since it use the integral image to make the mean images with different filter sizes for subtraction between the original image and the respective mean image. In addition, we propose the implementation of real-time embedded system using FPGA.

FFT를 이용한 화재 열영상의 주파수 스펙트럼 분석 (A Frequency Spectrum Analysis based on FFT of Fire Thermal Image)

  • 김원호;장복규
    • 융합신호처리학회논문지
    • /
    • 제12권1호
    • /
    • pp.33-37
    • /
    • 2011
  • 본 논문은 FFT를 이용한 적외선 화재 열영상의 주파수 스펙트럼 분석에 관한 것으로 영상처리를 통하여 화재 발생 유무를 주파수 영역에서 판별하기 위한 조건을 도출하는 것이 목적이다. 적외선 열영상의 주파수 스펙트럼 분석은 고속 푸리에 변환을 이용하여 수행하였으며, 화재로 추정되는 고명도의 영역을 화재 후보영역으로 결정한 다음, 연속적인 열영상의 해당영역에 대하여 DC 및 AC 주파수 분포를 분석하였다. 분석된 결과를 기반으로 정적인 오검출 요소와 동적특성을 가지는 화재영역을 구분하는 열영상의 화재 판정 기준을 제시하고 컴퓨터 모의실험을 통하여 실용성을 확인하였다.

정맥 관찰용 소형 근적외선 영상 시스템에서의 비지역적평균 알고리즘 적용 가능성 연구 (Application Feasibility Study of Non-local Means Algorithm in a Miniaturized Vein Near-infrared Imaging System)

  • 정현우;이영진
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.679-684
    • /
    • 2023
  • 정맥의 천자는 병리학적 검사를 위한 혈액 샘플을 획득하기 위해 널리 사용되고 있다. 바늘을 사용한 침습적인 정맥 천자 방법이 반복되서 시행되면 환자가 받는 고통이 증가되는 문제가 있어 본 연구팀은 사전에 소형 근적외선 (near-infrared, NIR) 영상 시스템을 개발하였다. 획득된 NIR 영상의 화질 개선을 위하여 본 연구에서는 노이즈 제거에 효율적으로 잘 알려진 비지역적 평균 (non-local means, NLM) 알고리즘을 모델링하여 시스템에서의 적용 가능성을 분석하고자 한다. 개발된 NIR 영상 시스템은 dichroic 및 long-pass filter를 적외선 (infrared, IR)이 통과하여 최종적으로 CMOS 센서 모듈로 검출되는 원리를 기반으로 구성하였다. 제안하는 NLM 알고리즘은 노이즈를 제거시키고자 하는 픽셀을 주변 픽셀들간의 거리들을 고려한 값으로 대체하는 원리를 기반으로 모델링하였다. 850 nm의 중심 파장을 가진 NIR 영상을 획득 후 NLM 알고리즘을 적용하여 히스토그램 평활화를 통해 최종 정맥 영역을 분할하였다. 결과적으로 NLM 알고리즘을 적용한 정맥의 NIR 영상의 coefficient of variation은 평균 0.247로 기존의 filtering 방법들과 비교하여 우수한 결과값으로 도출되었다. 또한 NLM 알고리즘의 dice similarity coefficient 값은 기존의 median filter와 total variation 방법에 비하여 각각 62.91 및 9.40% 향상된 값이 획득되었다. 결론적으로 NLM 알고리즘은 NIR 영상 시스템으로 획득한 정맥의 정확한 분할이 가능하게 할 수 있음을 증명하였다.

Near-infrared face recognition by fusion of E-GV-LBP and FKNN

  • Li, Weisheng;Wang, Lidou
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권1호
    • /
    • pp.208-223
    • /
    • 2015
  • To solve the problem of face recognition with complex changes and further improve the efficiency, a new near-infrared face recognition algorithm which fuses E-GV-LBP and FKNN algorithm is proposed. Firstly, it transforms near infrared face image by Gabor wavelet. Then, it extracts LBP coding feature that contains space, scale and direction information. Finally, this paper introduces an improved FKNN algorithm which is based on spatial domain. The proposed approach has brought face recognition more quickly and accurately. The experiment results show that the new algorithm has improved the recognition accuracy and computing time under the near-infrared light and other complex changes. In addition, this method can be used for face recognition under visible light as well.

3차원 Navigator에 적용할 적외선 시스템의 구성 (An Implementation of an Infrared System for the 3D Navigator)

  • 신동익;허수진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.315-316
    • /
    • 1998
  • The purpose of this study is a potentiality examination of an infrared camera system for the 3D navigator which can be used in the field of neurosurgery. Nowadays, CAS(computer aided surgery) technique using 3D navigator is rapidly spread into the neurosurgeric operation such as brain and spine surgery. Several techniques which can detect 3D position of a probe have been proposed. These include mechnical arm, magnetic field, optical and ultrasonic sensing methods. In this study, we decided that using optical sensing method and tested a conventional CCD camera with a infrared filter and LEDs. Pulnix TM-300 camra has sufficient spectral response in the range of near infrared. Acquired image of infrared LEDs also sufficient quality.

  • PDF

의료용 적외선 영상장치의 구현 (Development of Medical Infrared Imaging System)

  • 이수열;우응제;조민형;송형빈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.17-20
    • /
    • 1993
  • With proper designs of infrared optic system and two dimensional scanning mechanism, a medical infrared imaging system has been developed. The infrared imaging system can be used for two dimensional imaging of surface temperature of human body by measuring the amount of infrared lights radiating from it. It hag been experimentally proven that the degree of temperature measurement accuracy of the developed system is under $0.1^{\circ}C$ with spatial resolution of 1 mrad, image matrix size of $256{\times}240$, and imaging time of 4 seconds.

  • PDF