• 제목/요약/키워드: inflow temperature

검색결과 350건 처리시간 0.026초

인위적 담수 유입에 의한 도암만의 환경변화와 식물플랑크톤 변동 (Size and Species Composition of Phytoplankton Related to Anthropogenic Environmental Changes in Doam Bay)

  • 양응렬;정병관;이어진;류동기;신용식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1183-1197
    • /
    • 2014
  • Doam Bay is an estuary where harmful algal blooms (HABs) such as red tides develop frequently in summer. The bay also is influenced by freshwater inflow from Tamjin River in upper regions as well as from an artificial lake in lower regions. Phytoplankton size and species composition were investigated at six stations located in the lower regions in April, June and July, 2007. Physical properties (temperature, salinity and SS) were intensively measured for 3 days (5 occasions) after the freshwater discharges from the dike. The freshwater discharge affected temperature, salinity and turbidity in the study sites adjacent to the freshwater lake. Phytoplankton biomass was larger in April than June and it increased more in July. An explicit shift of species composition was observed. Diatoms were dominant in April and June (>70%) whereas their abundances greatly decreased and chlorophytes increased in July. Pseudo-nitzschia sp. was dominant at all stations (except St. 2) and this change was also detected in ecological indices such as diversity and dominance index.

Cochlodinium polykrikoides 적조발생에 있어 증식촉진물질의 기원과 지하해수의 수질 (Water Quality of Ground Seawater and Trigger Elements for a Cochlodinium polykrikoides Red Tide)

  • 이영식;김윤빈;한형균
    • 한국환경과학회지
    • /
    • 제21권9호
    • /
    • pp.1079-1085
    • /
    • 2012
  • Ground seawater quality was investigated, and the algal growth potential (AGP) tests were performed along the Tongyeong coast to examine the inflow of materials, which is needed for the red tide species Cochlodinium polykrikoides to grow. The study was conducted to determine the mechanism for C. polykrikoidesred tides. Water temperature, salinity, pH, and dissolved oxygen (DO) ranged from 16.05 to $20.74^{\circ}C$, 18.20 to 32.11 psu, 6.00 to 7.61, and 3.41 to 7.91 mg/L (41.4-96.1%), respectively. No seasonal variation was observed in water temperature. The salinity, pH, and DO saturations at most stations were lower than those of coastal seawater at Tongyeong. The ${NH_4}^+$-N, ${NO_{2+3}}^-$-N, ${PO_4}^{3-}$-P concentrations ranged from 0.43 to 16.00 ${\mu}M$, 1.50 to 132.38 ${\mu}M$, and 1.30 to 6.29 ${\mu}M$, respectively; the values at some stations were much higher than observed in Tongyeong coast seawater. Using seawater from station B, C. polykrikoides grew consistently, with a high growth rate, similar to the red tide in nature. This seawater appeared to contain materials needed by C. polykrikoides to grow. Therefore, C. polykrikoides red tides seem to occur wherever the ground sea water contains materials that are needed for its growth.

Dynamically Induced Anomalies of the Japan/East Sea Surface Temperature

  • Trusenkova, Olga;Lobanov, Vyacheslav;Kaplunenko, Dmitry
    • Ocean and Polar Research
    • /
    • 제31권1호
    • /
    • pp.11-29
    • /
    • 2009
  • Variability of sea surface temperature (SST) in the Japan/East Sea (JES) was studied using complex empirical orthogonal function (CEOF) analysis. Two daily data sets were analyzed: (1) New Generation 0.05o-gridded SST from Tohoku University, Japan (July 2002-July 2006), and (2) 0.25o-gridded SST from the Japan Meteorological Agency (October 1993-November 2006). Linkages with wind stress curl were revealed using 6-h 1o-gridded surface zonal and meridional winds from ancillary data of the Sea- WiFS Project, a special National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) product (1998-2005). SST anomalies (SSTA) were obtained by removing the seasonal signal, estimated as the leading mode of the CEOF decomposition of the original SST. Leading CEOF modes of residual SSTA obtained from both data sets were consistent with each other and were characterized by annual, semiannual, and quasi-biennial time scales estimated with 95% statistical significance. The Semiannual Mode lagged 2 months behind the increased occurrence of the anticyclonic (AC) wind stress curl over the JES. Links to dynamic processes were investigated by numerical simulations using an oceanic model. The suggested dynamic forcings of SSTA are the inflow of subtropical water into the JES through the Korea Strait, divergence in the surface layer induced by Ekman suction, meridional shifts of the Subarctic Front in the western JES, AC eddy formation, and wind-driven strengthening/weakening of large-scale currents. Events of west-east SSTA movement were identified in July-September. The SSTA moved from the northeastern JES towards the continental coast along the path of the westward branch of the Tsushima Current at a speed consistent with the advective scale.

표층수를 방류하는 저수지(용담호)에서 몬순 탁수환경의 공간적 해석 (Spatial Interpretation of Monsoon Turbid-water Environment in a Reservoir (Yongdam) Discharging Surface Water, Korea)

  • 신재기;허진;이흥수;박재충;황순진
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.933-942
    • /
    • 2006
  • In this study, temperature, turbidity, suspended paniculate matter (SPM) distribution and mineral characteristics were investigated to explain spatial distribution of the turbid-water environment of Yongdam reservoir in July, 2005. Six stations were selected along a longitudinal axis of the reservoir and sampling was conducted in four depths of each station. Water temperature was showed the typical stratified structure by the effects of irradiance and inflow. Content of inorganic matter in suspended particles increased with the concentration of suspended particulate matter (SPM) due to the reduction of ash-free dry matter (AFDM). Turbidity ranged from 0.6 to 95.1 NTU and the maximum turbidity value of each station sharply increased toward downstream from upstream. The high turbidity layers were located at the depth between 12~16 m. Particle size ranged from 0.435 to $482.9{\mu}m$. day and silt-sized particles corresponded 91.9~98.9% and 1.1~8.0% in total numbers of SPM, respectively. Turbidity showed high correlations with clay (r=0.763, p<0.05) and silt content (r=0.870, p<0.05).Inorganic matter content (r=0.960, p<0.01) was more correlated with turbidity than organic matter (r=0.823, p<0.05). Mineral characterization using x-ray diffraction and electron probe microanalyzer demonstrated that the major minerals contained in the SPM were kaolinite, illite, vermiculite and smectite. As results of this study, surface water discharge as well as small size of the SPM were suggested as long-term interfering factors in settling down the turbid water in the reservoir.

파주생태습지의 부착규조를 이용한 생물학적 수질평가 (The biological assessment of water quality using DAIpo and TDI of Paju Ecological wetland)

  • 김용진;김헌년;이옥민
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.229-238
    • /
    • 2012
  • This research was to examine the physiochemical factors and the attached diatoms of ecological wetland in Paju from August 2010 to May 2011. As a result of physicohemical water quality assessment, the water temperature did not fluctuate much due to ample riparian vegetation and aquatic plants growing at the site. Due to the effect of Han River Estuary, site 4, 5 and 6 had high electricity conductivity. The BOD concentration was high at site 2, 3, and 4 caused by decrease in water quantity and inflow of polluted water. At all sites, T-N and T-P concentrations ranged from eutrophic to hypertrophic status. At the downstream, the T-N and T-P concentrations decreased by inhabiting aquatic plant. Total of 98 taxa of attached diatoms were found. As for dominant taxa, Achnanthes convergens, A. minutissima, Gomphonema gracile, G. parvulum, Melosira varians, Navicula seminulum, N. minima, N. pseudolanceolata, Nitzschia amphibia, N. palea, Surirella minuta and Synedra ulna var. fragilariodes appeared. The result of biological assessment of water quality rated the sites B(suboptimal)~D(poor) during seasons of low water temperature, Fall and Winter, with DAIpo ranging 24.1~68.2 and TDI of 48.4~85.6. During Spring and Summer, all sites were rated D(poor) with DAIpo lower than or equal to 40, and TDI above or equal to 70. The biological assessment of water quality at the research site showed inferior TDI result compared to that of DAIpo.

복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향 (Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center)

  • 최병보;전현식;윤석일;김석환;이상진;김수민
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

L자형 배관내 물의 결빙에 관한 해석적 연구 (Numerical Analysis on the Freezing Process of Internal Water Flow in a L-Shape Pipe)

  • 이충호;서정세
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.144-150
    • /
    • 2018
  • In this study, the freezing process of L-shaped pipe exposed to the outside was investigated numerically by considering the mushy zone of freezing water. From the numerical results, it was found that the flow was outwardly directed due to the influence of the L-shaped bending part in the outside exposed part of the pipe, and the ice was formed in the shape of longitudinal corrugation on the wall surface of the pipe after the bending part. It is confirmed that this phenomenon is caused by the venturi effect due to the freezing as seen in connection with the velocity distribution in the pipe. It is found that the remelting phenomenon at the end of the freezing section occur simultaneously during the process of forming the ice in the pipe section. In regard of the factors affecting freezing, it was found that the thickness of the freezing layer is increased as the exposed pipe surface temperature is decreased, and the pipe surface temperature had a significant effect on the change of the freezing layer thickness. At the same time, it was found that the freezing layer becomes relatively thin when the water inflow rate is increased. This phenomenon was caused by reducing the exposure time of freezing water due to the vigorous flow convection of the water fluid.

다변량 통계분석을 이용한 북한강의 수질 및 식물플랑크톤 군집 특성 평가 (Evaluation of Water Quality and Phytoplankton Community Using a Multivariate Analysis in Bukhan River)

  • 김헌년;윤석제;변명섭;유순주;임종권
    • 한국물환경학회지
    • /
    • 제35권1호
    • /
    • pp.19-27
    • /
    • 2019
  • The purpose of this study is to evaluate the water quality and phytoplankton community in Bukhan River which account for 44.4 % of the total inflow into Lake Paldang, using multivariate statistical techniques (i.e., correlation analysis, principal component analysis (PCA)/factor analysis (FA)). Water samples were collected from March to November 2015 and the following parameters measured; water temperature, pH, DO, EC, SS, BOD, Chl-a, COD, TN, $NO_3-N$, $NH_3-N$, TP, DTP, $PO_4-P$, and phytoplankton community. The water quality of the main stream and the tributaries were not significantly different apart from the relatively high concentration of BOD, COD and nutrients recorded in MH. The highest cell density of Stephanodiscus hantzschii and Merismopedia glauca dominated phytoplankton was observed in PD. Based on the correlation analysis, total phytoplankton and cyanophyceae were highly correlated with BOD, COD and nutrients. PCA/FA resulted in four main factors accounting for 82.240 % of the total variance in the water quality dataset. The group of component 1 (TN, DTN, DO, $NO_3-N$, water temperature) and component 2 ($PO_4-P$, T-P, DTP, SS) were classified as nutrient element factor whereas component 3 (Chl-a, COD, BOD, $NH_3-N$, pH) was related to organic substances. Hence, the identification of the main potential environmental pollution factors in Bukhan River will help policy makers make better and more informed decisions on how to improve the water quality.

아세트알데히드 제거를 위한 Mn-Cu 금속촉매 실용화에 관한 연구 (Practical Application of Mn-Cu Metal Catalyst for the Removal of Acetaldehyde)

  • 정성철;이승환
    • 디지털융복합연구
    • /
    • 제10권8호
    • /
    • pp.201-210
    • /
    • 2012
  • 악취는 사람마다 느끼는 정도가 다르므로 법적 배출허용농도 이내로 배출된다고 하더라도 민원 발생 시 사회적으로 이슈화가 되는 특징이 있다. 본 연구는 산업공정에서 발생된 악취중의 아세트알데히드를 경제적으로 제거하기 위해 Mn-Cu 금속산화물 촉매의 실용화 가능성에 관한 연구이며, 실험실에서 성능평가를 통해 아세트알데히드 제거를 위한 최적 운전인자를 도출하였고, 파일럿 규모의 Scale-up을 통한 현장 실험으로 실제규모 시설에 적용하여 성능을 검증하였다. 지금까지 연구되어진 금속산화물 촉매의 운전온도는 최소 $220^{\circ}C$ 근방에서 아세트알데히드 제거효율이 50% 이하였다. 그러나 본 연구에서 Mn-Cu 금속산화물 촉매를 사용하여 실험한 결과 공간속도(GHSV)가 6,000 $hr^{-1}$ 이하일 때 최적의 제거효율을 보였으며, 촉매제어 온도가 $120^{\circ}C$일 때 평균 제거효율은 61.2%, $160^{\circ}C$에서는 93.3%, $180^{\circ}C$에서는 94.9%로 높은 제거효율을 보였다. 촉매의 비표면적은 사용 전 $200m^2/g$이었으나 24개월 경과 시 $47.162m^2/g$으로 나타나 비표면적은 시간이 지남에 따라 줄어들지만 성능에는 큰 영향이 없었고, 황화합물과 산성가스 등과 같은 피독물질이 유입되지 않는 현장에서 Mn-Cu 금속산화물 촉매장치를 2년 이상 운전한 결과 90% 이상의 제거효율이 유지되고 있는 것을 확인할 수 있었다.

터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향 (Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.187-193
    • /
    • 1996
  • 여름철 고온기 참외재배시 환기방법에 따른 시설내 온도차이가 참외의 생육 및 품질에 미치는 영향을 구명하고자 측면환기공 환기구(Type 1), 측면환기공 환가+천정 환기공 환기구(Type 2) 및 권취식 환기구(Type 3)로 구분하여 시험을 실시한 결과를 요약하면 다음과 같다. 1. 환기방법별 온도의 하강효과는 Type 3이 가장 좋았고 Type 2, Type 1의 순으로 나타났다. 2. 환기방법에 따른 온도분포는 측면환기공만 있는 Type 1과 천정환기통 및 측면환기공이 있는 Type 2의 경우 환기공 및 환기통의 면적이 적어 중력환기 및 풍력환기가 미세하여 온도가 상승하였다. Type 3은 측면환기 면적이 넓어 풍력환기에 의한 공기의 유입, 유출이 쉬워 온도분포가 비교적 균일하였다. 3. 실측치를 이용하여 내외기온차이에 의한 환기량을 추정한 결과, Type 3이 Type 1 및 Type 2보다도 많음을 알 수 있었다. 4. 생육 및 상품성을 조사한 결과, Type 3이 Type 2, Type 1보다도 엽수 및 엽면적이 증가하여 생육이 양호하였고 과중, 과육두께, 기형과율, 상품과율 등 상품성도 우수하였다. 5. 수확시기별 상품수량은 각처리 공히 수확초기 보다는 후기로 갈수록 증가하였다. 특히 Type 3에서 뚜렷한 경향을 보였다.

  • PDF