• Title/Summary/Keyword: infiltration effect

Search Result 837, Processing Time 0.034 seconds

외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포 (The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings)

  • 박주현;윤성민;송두삼;김용식
    • 도시과학
    • /
    • 제8권1호
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

침투형 빗물받이의 배수 및 비점오염물질 저감 효과 (Reduction Effect of Nonpoint Source Pollutants and Drainage of Infiltration Grate Inlet)

  • 이원용;임봉수;박인성
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.474-480
    • /
    • 2017
  • This study was to estimate the reduction effect of nonpoint source pollutants according to the rainfall intensity and drainage of infiltration grate inlet. Soil infiltration flow was measured on-site and SS load by the filter part was calculated by the experimental data in laboratory reactor test. Soil infiltration flow was measured to be about $1m^3/hr$ in soil condition saturated with water. The filter part of the infiltration grate inlet was a hydraulic equipment unhindered by soil infiltration on the bottom of the storage tank, because the infiltration flow was measured to be about $3m^3/hr$ continuously in the closing infiltration hole condition. Infiltration flow and SS load were over about $1m^3/hr$ and 1.71 kg according to laboratory results by the filter part using the artifical sample. Therefore, the above values could be presented as the limitted value to start the reduction of filtration effect. Reduction efficiencies of SS load by the filter part for the rainfall intensity were about 87 % at 5 mm/hr and about 61 % at 10 mm/hr in consideration of one infiltration grate inlet got the drainage area about $200m^2$. The reduction efficiency of nonpoint source pollutants was very effective in the first flush rainfall. However, the reduction efficiency by rainfall density was higher than by flow.

단열재 두께 변화와 창호 침기 부하와의 관계 (A Study on Relationship Insulation Thickness and Infiltration Load by Window)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.

도시유역에서 침투시설의 우수유출저감효과 분석 (An Analysis of Runoff Reduction Effect of Infiltration Facilities in Urban Area)

  • 이재준;김호년;곽창재;이상원
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.628-631
    • /
    • 2007
  • One of the structural measures for the peak flow reduction is infiltration facilities. There are many types in infiltration facilities - infiltration basin, trench, bed, porous pavement, percolated subdrain, dry well. In this study runoff reduction effect of infiltration trench is analyzed by WinSLAMM. Runoff reduction effect is investigated by each design rainfall and temporal pattern of rainfall particularly. The biggest reduction is shown in Yen and Chow's temporal pattern of design rainfall and the smallest reduction is shown in Huff's first quartile pattern. Runoff reduction rate is presented about 6 to 14 percentage, and the larger return period, the smaller runoff reduction rate.

  • PDF

Effect of soil physical properties on infiltration rate

  • Sajjadi, Sayed-Abdul-Hamid;Mirzaei, Maryam;Nasab, Afsaneh Fayyaz;Ghezelje, Amin;Tadayonfar, Gholamreza;Sarkardeh, Hamed
    • Geomechanics and Engineering
    • /
    • 제10권6호
    • /
    • pp.727-736
    • /
    • 2016
  • Excessive rainfall can cause runoff flows over the soil surface and as a consequence some amount of water will infiltrate into the soil. From a hydrologic modeling perspective it is necessary to estimate infiltration rate in order to calculate the actual runoff discharge. There are many parameters that can affect the infiltration rate such as soil texture, moisture and compaction. However, the most common equations used in hydrological calculations for estimating the infiltration rate do not consider the soil properties directly and estimate infiltration rate without any soil properties expressions. The purpose of this research was to investigate the relations between infiltration rate and soil texture, moisture and compaction. To achieve this purpose an experimental study was performed to show the effect of soil properties and their relations on infiltration rate by using non-linear regression.

빗물 유출면 및 빗물 침투시설이 주거단지 유출빗물의 pH에 미치는 영향 (The Effect of Impermeable Surface and Rainwater Infiltration Facilities on the Runoff pH of Housing Complexes)

  • 현경학;최정주;정연규
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.39-47
    • /
    • 2010
  • In order to examine the effect of impermeable surface (rooftop, outdoor parking lot) and rainwater infiltration facilities on runoff pH, pH was measured. pH measurement spots were splash blocks accepted roof runoff of 3 sites, infiltration boxes and trenches accepted parking lot runoff and plastic rainwater harvesting facility accepted roof runoff. These measurements were operated at 3 housing complexes from 2006 to 2009. The rainwater runoff pH was influenced by the quality of the runoff surface material (concrete), the age of the building, waterproofing methods according to each housing site, antecedent rainfall conditions and others. Rain garden, infiltration boxes and trenches decreased the alkalinity of runoff by detention and infiltrating the roof and outdoor parking lot runoff. These results mean that decentralized rainwater management facilities of housing complexes can reduce effect on the outskirt aquatic ecosystem by the accumulation of substances causing pH rising in the infiltration facilities and rain garden.

Effect of Powder Size on Infiltration Height in Producing MgO Reinforced Al Matrix Composite by Vacuum Infiltration Method

  • Calin, Recep;Citak, Ramazan
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1271-1272
    • /
    • 2006
  • The vacuum infiltration method is one of the composite producing methods. There are several parameters in composite production by vacuum infiltration. One of them is particle size of reinforcement in particulate reinforced composites. In this study, MgO powder and Al were used as reinforcement and matrix respectively. MgO powders with different size and amount to give same height were filled in quartz tubes and liquid metal was vacuum infiltrated into the MgO powder under same vacuum condition and for same time. Infiltration height was measured and microstructure and fracture behavior of composite were investigated. It has been found that infiltration height and fracture strength were increased with particulate reinforcement sizes. It has also been determined that molten metal temperature facilitates infiltration.

  • PDF

유출저감을 위한 유역내 침투시설의 적용 (An Application of Infiltration Facilities for Reducing the Runoff in the Basin)

  • 이재준;설지수
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.133-141
    • /
    • 2011
  • 유역의 도시화는 유출총량과 첨두유량의 증가와 도달시간이 감소시키며, 홍수피해의 위험성을 더욱 크게 만든다. 침투시설은 도시유역의 유출총량과 첨두유량을 감소시킬 수 있고, 그 종류에는 침투트렌치와 투수성 포장재 등이 있다. 본 연구에서는 침투시설 설치에 따른 우수유출저감효과를 알아보기 위하여 경북 구미시 옥계동의 $0.18km^2$와 공단동의 $0.67km^2$의 면적을 가진 도시유역을 대상으로 하여 각각의 유역특성을 분석하고, 유출총량 및 첨두유량의 저감량을 WinSLAMM 모형을 이용하여 분석하였다. 또한, 침투시설 설치에 따른 첨두유량저감효과를 분석하였고, 침투시설 면적비와 유출저감률과의 관계식을 도출하였다.

침투형 우수유출 저감시설의 저감효과 개선에 관한 실험 연구 : 누가침투량 분석에 의한 침투-저류시스템 제안 (An Experimental Study on Improvement of the Effect for Runoff Reducing Facilities Using Infiltration)

  • 임장혁;송재우;박영진
    • 한국지반환경공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.5-13
    • /
    • 2009
  • 최근 지속적이고 건전한 물 관리를 위하여 침투형 우수유출 저감시설이 고려되고 있는 실정이다. 그러나 침투형 우수유출저감시설의 실제 적용에는 많은 문제점에 대한 개선이 필요하다. 본 연구에서는 침투형 우수유출 저감시설에 대한 개선 방법으로 침투-저류 시스템(ISS)을 제안하고, 수리모형 실험에 의해 우수유출 저감효과를 분석하였다. 본 연구에서 새로 제안된 우수유출 저감시설의 침투 특성을 분석하기 위해 다양한 강우 조건과 택지 개발 및 도시화를 고려하기 위해 실제 택지 개발시 이용되는 표면재료를 적용하였다. 본 연구에서는 수리모형 실험결과에 따라, 하부층의 누가 침투량에 의해서 침투-저류 시스템(ISS)은 부가적인 저감효과를 나타냈으며, 강우강도가 증가함에 따라 누가 침투율도 증가하였다. 그러므로 침투-저류 시스템(ISS)은 침투율이 증가하므로 기존 우수유출 저감시설보다 더 효과적으로 나타났다. 이러한 결과는 침투-저류 시스템(ISS)의 우수유출저감시설로써 적용에 대한 타당성을 확보할 수 있으며, 향후 관련 연구가 수행되면 침투-저류시스템(ISS)은 실제 우수유출 저감시설로써 활용될 수 있을 것이다.

  • PDF

조립식 저류형 침투시설의 설계 및 공간적용 효과분석 (Design and Effectiveness Analysis of prefabricated Storage-type infiltration facility)

  • 이태구
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: This study has developed economical and environmentally friendly storage type infiltration facilities that securing storage space inside the infiltration facility. It focused on preventing flooding rainfall as well as securing more groundwater through rainwater infiltration that is valuable for the dry season. In addition, this study compares the installation cost of the storage-type infiltration facility to the cost of the conventional rainwater management facilities to demonstrate the economic efficiency of the storage-based infiltration facility. Method: Unit infiltration of this facility is calculated and when it was applied to a certain capacity, the amount of countermeasures are proposed in case study. Result: Unit infiltration of it is $0.2541m^3/hr$ and un it Temporary storage of it is $1.054m^3/m$. As a result, the infiltration effect of this facility is $1.306m^3/hr$. The cost was approximately 30% reduction in time to apply the storage type infiltration facility as compared with the case to apply the existing penetration of the facilities. Since the penetration of the existing facilities is smaller than that and it has much securing volume to process the same the amount of countermeasures. Therefore, it is determined that the cost significantly increases in material cost part. On the other hand, storage type infiltration facility is installed a small quantity because Unit Temporary storage and infiltration are bigger than that. So, it occurred to reduce material and installation costs.