• 제목/요약/키워드: inelastic structures

검색결과 521건 처리시간 0.023초

지진의 특성주기를 고려한 완만한 곡선형 이력거동시스템의 비탄성 변위비 (Inelastic Displacement Ratios for Smooth Hysteretic System Considering Characteristic Period of Earthquakes)

  • 송종걸
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.1-10
    • /
    • 2013
  • In order to predict inelastic displacement response without nonlinear dynamic analysis, the equal displacement rule can be used for the structures with longer natural periods than the characteristic period, $T_g$, of earthquake record. In the period range longer than $T_g$, peak displacement responses of elastic systems are equal or larger than those of inelastic systems. In the period range shorter than $T_g$, opposite trend occurs. In the equal displacement rule, it is assumed that peak displacement of inelastic system with longer natural period than $T_g$ equals to that of elastic system with same natural period. The equal displacement rule is very useful for seismic design purpose of structures with longer natural period than $T_g$. In the period range shorter than $T_g$, the peak displacement of inelastic system can be simply evaluated from the peak displacement of elastic system by using the inelastic displacement ratio, which is defined as the ratio of the peak inelastic displacement to the peak elastic displacement. Smooth hysteretic behavior is more similar to actual response of real structural system than a piece-wise linear hysteretic behavior such as bilinear or stiffness degrading behaviors. In this paper, the inelastic displacement ratios of the smooth hysteretic behavior system are evaluated for far-fault and near-fault earthquakes. The simple formula of inelastic displacement ratio considering the effect of $T_g$ is proposed.

Inelastic lateral-distortional buckling of continuously restrained continuous beams

  • Lee, Dong-Sik
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.305-326
    • /
    • 2005
  • The inelastic buckling behaviour of continuously restrained two and three-span continuous beams subjected to concentrated loads and uniformly distributed loads are studied in this paper. The restraint type considered in this paper is fully restrained against translation and elastic twist applied at the top flange. These types of restraints are most likely experienced in industrial structures, for example steel-concrete composite beams and half through girders. The buckling analysis of continuous beam consists of two parts, firstly the moment and shear distribution along the member are determined by employing force method and the information is then used for an out-of-plane buckling analysis. The finite element method is incorporated with so-called simplified and the polynomial pattern of residual stress. Owing to the inelastic response of the steel, both the in-plane and out-of-plane analysis, which is treated as being uncoupled, extend into the nonlinear range. This paper presents the results of inelastic lateral-torsional and lateral-distortional buckling load and finally conclusions are drawn regarding the web distortion.

실용적인 비선형 비탄성해석을 이용한 강구조 설계기술 (Design Technique of Steel Structures using Practical Nonlinear Inelastic Analysis)

  • 김승억;이동호;장은석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.971-976
    • /
    • 2006
  • This paper presents a design technique of steel structures subjected to static and dynamic loadings using practical nonlinear inelastic analysis software. The beam-column approach using the stability functions and the plastic hinge concept enables the software to suitably predict second-order effects and inelastic behavior of beam-columns. For dynamic analysis. the incremental from of the equation of motion is solved by the use of a step-by-step numerical integration procedure in which the assumption of constant acceleration over a small time step is employed. The accuracy of the analysis program is validated using the results of ABAQUS program and experimental tests. A user-friendly graphic interface of the software is developed to facilitate the modeling process and result interpretation of the problem. A design example of large span bridge is presented to detail the direct design process using the practical advanced analysis software.

  • PDF

비탄성 설계 스펙트럼에 의한 이력 모델의 효과 (Effect of Hysteretic Models on the Inelastic Design Spectra)

  • 한상환;오영훈;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.214-224
    • /
    • 1999
  • The design response spectrum has been widely used in seismic design to estimate force and deformation demands of structures imposed by Earthquake Ground Motion (EQGM). Inelastic Design Response Spectra (IDRS) to specify design yielding strength in seismic codes are obtained by reducing the ordinates of Linear Elastic Design Response Spectrum (LEDRS) by strength reduction factor (R). Since a building is designed using reduced design spectrum (IDRS) rather than LEDRS in current seismic design procedures it allows structures behave inelastically during design level EQGM. Inelastic Response Spectra (IRS) depend not only on the characteristics of the expected ground motion at a given site, but also on the dynamic properties and nonlinear characteristics of a structure. However, it has not been explicitly investigated the effect of different hysteretic models on IRS. In this study, the effect of hysteretic models on IRS is investigated.

  • PDF

비탄성 설계스펙트럼에 대한 이력거동 특성의 영향 (Effect of Hysteretic Characteristics on Inelastic Seismic Design Spectra)

  • 오영훈;한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.207-214
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". The effect of hysteretic behavior, as well as maximum ductility ratio and period on the inelastic strength demand is investigated. Special emphasis is given to the effects of the hysteretic characteristics such as strength degradation or pinching. Results indicate that inelastic strength demands are strongly dependent on level of inelastic deformation, period and hysteretic behavior.

  • PDF

역량스펙트럼 방법을 이용한 구조물의 비탄성 응답의 평가 (Inelastic Response Evaluation of Structures using Capacity Spectrum Method)

  • 송종걸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.161-168
    • /
    • 2002
  • To evaluate seismic performance of bridges, two procedures far capacity spectrum method are presented. The capacity spectrum procedures include the reduction factor-ductility-period relationship in order to construct the inelastic demand spectra from the elastic demand spectra. Application of the procedures is illustrated by example analysis. Maximum displacements estimated by the procedures are compared to those by inelastic time history analysis for several artificial earthquakes. The results show that the maximum displacements estimated by the procedures are, on overall, smaller than those by the inelastic time history analysis

  • PDF

수평접합부의 비탄성 특성을 고려한 프리캐스트 대형판넬 구조물의 비선형 해석에 관한 연구 (Nonlinear Analysis of Precast Large Panel Structures Considering the Inelastic Properties of Horizontal Joints)

  • 정일영;최완철;송진규;강해관
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.45-52
    • /
    • 1995
  • The stability and integrity of precast large panel structures are analyzed with nonlinear mathematical model considering the inelastic properties of horizontal joints. In this research, an analysis for cyclic loading test was carried out by the macro model that idealized the horizontal joints as inelastic-nonlinear spring systems. As a results, the strain hardening ratio of shear slip element was estimated as about 0.05%- 0.2% of initial shear stiffness. And under lateral load, the rocking motion due ti overturning moment was dominant rather than shear slip motion in the behavior of precast structures.

  • PDF

등가 1자유도계에 의한 다자유도 비선형 지진응답 산정 (Evaluation of Inelastic Earthquake Response of MDOF System by Equivalent SDOF System)

  • 김부식;노필성;전대한;송호산
    • 한국공간구조학회논문집
    • /
    • 제2권2호
    • /
    • pp.45-49
    • /
    • 2002
  • Current seismic design codes for building structures are based on the methods which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. This paper is to suggest the method of inference of inelastic earthquake response obtained from MDOF system by equivalent SDOF system, and to prove the validity. The analysis results form simple model shows a good application possibility.

  • PDF

철골조를 위한 직접비탄성설계법의 적용 (Application of Direct Inelastic Design for Steel Structures)

  • 엄태성;박홍근
    • 한국강구조학회 논문집
    • /
    • 제17권1호통권74호
    • /
    • pp.103-113
    • /
    • 2005
  • 본 연구에서는 선행 연구에서 개발된 강구조물에 대한 직접비탄성설계 방법을 설계실무의 활용성을 확대할 수 있도록 개선하였다. 그룹부재에 대한 설계, 불연속적인 단면 성능, 축력에 따른 휨재하능력의 변화, 접합방식에 따른 거동특성, 다중하중조건 및 성능기준 등 강구조물 설계실무의 제한조건을 고려하여 비탄성설계를 수행할 수 있는 방법을 개발하였다. 본 연구에서는 제안된 방법의 해석 및 설계절차를 정립하였고, 이를 적용한 컴퓨터 해석/설계 프로그램을 개발하였다. 전통적인 탄성설계와 제안된 직접비탄성설계법을 사용한 설계결과를 비교하였으며, 기존의 비선형해석프로그램을 이용하여 설계결과를 검증하였다. 비탄성 변형을 고려할 수 있는 제안된 설계법은 전통적인 탄성해석을 사용한 한계상태설계에 비하여 강재량을 절감하고, 구조물의 변형능력을 향상하였다. 제안된 설계방법은 비탄성 거동을 구조물의 설계에 직접 반영할 수 있으므로 설계에 편리하고 각 소성힌지의 변형을 제어함으로써 구조안전성을 확보하고 동시에 변형능력을 최대로 활용하는 설계를 수행할 수 있다.

확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가 (Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure)

  • 최인길;서정문
    • 한국지진공학회논문집
    • /
    • 제5권5호
    • /
    • pp.47-56
    • /
    • 2001
  • 원전 격납건물은 내진 안정성을 확보하기 위해 설계단계에서 여유나 보수성을 부여하게 된다. 원전 구조물의 내진성능 평가는 이러한 여유나 보수성을 배제한 실질적인 성능 및 응답을 기준으로 평가하게 된다. 본 연구에서는 내진성능 평가에 고려되는 구조물의 성능 및 응답관련 계수들 중 그 기여도가 비교적 큰 비탄성 에너지 흡수계수의 산정방법에 대한 비교를 수행하였다. 또한 각종 방법에 따라 산정된 비탄성 에너지 흡수계수에 따른 HCLPF(high confidence of low probability of failure)값의 변화를 분석하였다. 연구결과 원전 격납건물의 비탄성 에너지 흡수계수는 1.5~1.75로 나타났다. 구조물의 내진성능을 명확히 평가하기 위해서는 먼저 구조물의 비선형 거동 및 연성도를 정확히 평가하여야 함을 알 수 있다.

  • PDF