• Title/Summary/Keyword: industrial sludge

Search Result 444, Processing Time 0.024 seconds

Study on Optimum Conditions for the Composting of Industrial Wastewater Sludge (공단 폐수 슬러지의 퇴비화 최적조건)

  • Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Su
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • To study the optimum conditions of composting with industrial wastewater sludge, the variations of temperature and $CO_2$ generation amount during the composting periods were investigated. The conditions were that industrial wastewater added to bulking agents such as sawdust and rice hull was used, and differently treated with microorganism seeding or not, initial C/N ratios, air flow rate and initial moisture contents, respectively. The results were summarized as follows : Seeding 5% of microorganism was higher the temperature than not seeding. And using sawdust as bulking agents, and adjusting 30~40 of Initial C/N ratio, 200ml/l.min. of k flow rate and 67~68% moisture contents were higher the temperature than any other conditions. Seeding 5% of microorganisms was higher $CO_2$ generation amount than not seeding. And that was much in the order of 7~40, 30~34 and 22~23 of initial C/N ratio. Judging from the results, it should be considered that the optimum conditions in the composting of industrial wastewater sludge were seeding of 5% microorganisms, and adjusting 30~34 of Initial C/N ratio, 200ml/l min. of air flow rate and 67~68% of Intitial moisture contents. The contents of inorganic matters and C/N ratio during the composting periods at optimum condition were a little Increased. and heavy metals contents after composting were lower than standard for fortllizer.

  • PDF

Study on the Co-firing of Sewage Sludge to a 80 kWth-scale Pulverized Coal Combustion System (80 kWth급 미분탄 연소 시스템에서 하수슬러지 혼소시 연소 특성 연구)

  • Chae, Taeyoung;Lee, Jaewook;Lee, Youngjae;Yang, Won
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.74-80
    • /
    • 2019
  • Thermochemical treatment of sewage sludge is an energy-intensive process due to its high moisture content. To save the energy consumed during the process, the hydrothermal carbonization process for sewage sludge can be used to convert sewage sludge into clean solid fuel without pre-drying. This study is aimed to investigate co-firing characteristics of the hydrothermally carbonated sewage sludge (HCS) to a pulverized coal combustion system. The purpose of the measurement is to measure the pollutants produced during co-firing and combustion efficiency. The combustion system used in this study is a furnace with a down-firing swirl burner of a $80kW_{th}$ thermal input. Two sub-bituminous coals were used as a main fuel, and co-firing ratio of the sewage sludge was varied from 0% to 10% in a thermal basis. Experimental results show that $NO_x$ is 400 ~ 600 ppm, $SO_x$ is 600 ~ 700 ppm, and CO is less than 100 ppm. Experimental results show that stable combustion was achieved for high co-firing ratio of the HCS. Emission of $NO_x$ and $SO_x$ was decreased for higher co-firing ratio in spite of the higher nitrogen contents in the HCS. In addition, it was found that the pollutant emission is affected significantly by composition of the main fuel, regardless of the co-firing ratios.

Flotation Characteristics of Activated Sludge by Micro-bubbles (미세 기포에 의한 활성슬러지의 부상특성)

  • Kim, Seong-Jin;Kang, Byoung-Jun;Park, Sang-Wook;Lee, Jae-Wook;Jung, Heung-Joe;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.501-507
    • /
    • 2006
  • Dissolved air flotation (DAF) has been well known for the gravity separation process. The solids to be separated are transferred from the water body to the water surface using micro-air bubbles. DAF has also been used for enhancing solids-liquid separation of industrial and municipal wastewater by adding a its unit parallel to a sedimentation unit to reduce the hydraulic loading in the sedimentation clarifier. This study was to investigate flotation characteristics of activated sludge by the recent DAF technique without chemical agents. In addition, the effect on temperature in flotation of activated sludge and the thickening degree of activated sludge were studied.

Thermal insulation property according to pearlite addition ratio of non cement matrix using paper ash and polysilicon sludge (제지애시와 폴리실리콘 슬러지를 활용한 무시멘트 경화체의 펄라이트 첨가율에 따른 단열특성)

  • Shin, Jin-Hyun;Kim, Dae-Yeon;Lee, Dong-Hoon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.165-166
    • /
    • 2018
  • Researches for the development of renewable energy as a fuel substitute for global warming and depletion of petroleum resources are actively being carried out. Among them, the annual growth rate of PV generation is 20.73%, which is higher than other renewable energy sources. However, the production of 1 ton of polysilicon, which is known as a raw material for solar power generation panels, generates 2 tons of waste. As the demand for PV panels increases, the problem of the treatment of polysilicon sludge is attracting attention, and studies on the utilization of polysilicon sludge are needed. Therefore, in this study, the applicability of polysilicon sludge treated as industrial waste to the lightweight panel for architectural purposes was examined.

  • PDF

Utilization of Industrial Waste to Organic Fertilizer for Lawn (산업폐기물의 잔디용 유기질 비료화에 관한 연구)

  • 주영규
    • Asian Journal of Turfgrass Science
    • /
    • v.5 no.2
    • /
    • pp.81-86
    • /
    • 1991
  • The sludge, a waste of brewery industries, was examined for potentials as a natural organic fertilizer (or soil conditioner) for lawn. Trial products were measured for changes of physical, chemical properties in laboratory and seed germination and seedling growth in green house were also tested. The results are as the following:1The sludge from distilled liquor brewery contained high quantity of organic matter which had proper physical and chemical properties for lawn fertilizer (natural organic fertilizer, soil conditioner, top-dressing mix) . It showed good characteristics in handling and capabilities to be developed as commercial products for golf courses. 2.Sludge from beer company needs proper treatment to improve physical properties for futher degradiation. It is because aggregation of the sludge particles prevented microbial activities and changing to soluble form. 3.Green carbon can be used as carbon source for organic fertilizer production using brewery sludge, but it should not contain wood extract which inhibit seed germination and seedling growth.

  • PDF

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

Study on the Emission Characteristics of Heavy metals in sewage sludge Incinerator (하수슬러지 소각시설의 중금속 배출특성에 관한 연구)

  • Park, Jung-Min;Lee, Sang-Bo;Kim, Min-Jung;Kim, Jin-Pil;Kim, Jong-Chooun;Lee, Suk-Jo;Lee, Sang-Hak
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.28-36
    • /
    • 2009
  • We have closely examined the concentration change characteristics, emission amounts, and the material balance of hazardous air pollutants at both early and later stages of the prevention facilities. These results will be uses as the basic data when preparing for the regulatory and management plans for hazardous air pollutants. The results of the study on heavy metals illustrated that the content of heavy metals in sludge across five facilities were as follows: copper> zinc> chrome> nickel> cadmium> mercury. In terms of heavy metal content in swage sludge, the sludge in incinerating facilities other than the sludge in the D incinerating facility containing industrial water waste, was examined in order to satisfy the ocean contamination standard and fertilizer specifications. Most of the items were shown to have satisfied the emission tolerance standards in the latter part of the prevention facilities(The average elimination rate was over 90%). Therefore, it is concluded that swage sludge containing high-concentrate heavy metals needs to be incinerated rather than recycled as fertilizer.

Development of Remote Controlled Bucket Driven Dredger for Sludge Treatment in Box Culvert (박스암거내 슬러지 처리를 위한 원격조정 버켓구동식 준설기 개발)

  • Kang, Sung-Jun;So, Byung-Moon;Park, Young-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2774-2779
    • /
    • 2010
  • In this paper, we develope the bucket driven dredger for sludge treatment in box type culvert. The dreadger is opererated in $2m\;{\times}\;2m$ box type narrow culvert under the road, and controlled using remote controller on the remote zone. In order to operate under dangerous environment, we develope the bucket drived dredger, and we will commercialize the result.

Incorporation of water sludge, silica fume, and rice husk ash in brick making

  • Hegazy, Badr El-Din Ezzat;Fouad, Hanan Ahmed;Hassanain, Ahmed Mohammed
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.83-96
    • /
    • 2012
  • The water sludge is generated from the treatment of water with alum. Disposing of sludge again to the streams raises the concentrations of aluminum oxides in water, which has been linked to Alzheimer's disease. The use of water treatment plant (WTP) sludge in manufacturing of constructional elements achieves both the economical and environmental benefits. Due to the similar mineralogical composition of clay and WTP sludge, this study investigated the complete substitution of brick clay by sludge incorporated with some of the agricultural and industrial wastes, such as rice husk ash (RHA) and silica fume (SF). Three different series of sludge to SF to RHA proportions by weight were tried, which were (25: 50: 25%), (50: 25: 25%), and (25: 25: 50%), respectively. Each brick series was fired at 900, 1000, 1100, and $1200^{\circ}C$. The physical and mechanical properties of the produced bricks were then determined and evaluated according to Egyptian Standard Specifications (E.S.S.) and compared to control clay-brick. From the obtained results, it was concluded that by operating at the temperature commonly practiced in the brick kiln, a mixture consists of 50% of sludge, 25% of SF, and 25% of RHA was the optimum materials proportions to produce brick from water sludge incorporated with SF and RHA. The produced bricks properties were obviously superior to the 100% clay control-brick and to those available in the Egyptian market.

Implementation of a silicon sludge recycling system for solar cell using multiple centrifuge (다중 원심분리법을 이용한 태양전지용 실리콘 폐 슬러지 재생 시스템 구현)

  • Kim, Ho-Woon;Choi, Byung-Jin
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • This paper explained about the sludge recycling system which retrieved the silicon and abrasive from solar cell wafer slicing. The basic process of the recycling system was multiple centrifuge and secondary processes of ultra sonic agitation, addition of alcohol-water solution and heating sludge was added for raising separation efficiency. The recycling rate was about 96% and 94% for 2N, 4N silicon respectively. The SiC abrasive recycling rate was about 80%. To retrieve the high purity of 4N silicon, the heat process in vacuum furnace was added to remove remaining impurity components.