• Title/Summary/Keyword: industrial column

Search Result 455, Processing Time 0.027 seconds

The Purification Characteristics of Reactive Soil-Bentonite Landfill Liner (혼합반응 차수재의 오염정화특성)

  • 김학문
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.398-403
    • /
    • 2003
  • The purpose of this paper is to investigate purification characteristic of soil-bentonite landfill liner and to develop a desirable liner system. In order to clarify the purification characteristics, high pressure column tests using soil-bentonite, reactive soil-bentonite and reactive bentomat were carried out in the presence of water and leachate. The test results indicated that the significant amount of NH$_3$-N, Pb and Cu was removed through the reactive soil-bentonite liner system.

  • PDF

EFFICIENT LATTICE REDUCTION UPDATING AND DOWNDATING METHODS AND ANALYSIS

  • PARK, JAEHYUN;PARK, YUNJU
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.19 no.2
    • /
    • pp.171-188
    • /
    • 2015
  • In this paper, the efficient column-wise/row-wise lattice reduction (LR) updating and downdating methods are developed and their complexities are analyzed. The well-known LLL algorithm, developed by Lenstra, Lenstra, and Lov${\acute{a}}$sz, is considered as a LR method. When the column or the row is appended/deleted in the given lattice basis matrix H, the proposed updating and downdating methods modify the preconditioning matrix that is primarily computed for the LR with H and provide the initial parameters to reduce the updated lattice basis matrix efficiently. Since the modified preconditioning matrix keeps the information of the original reduced lattice bases, the redundant computational complexities can be eliminated when reducing the lattice by using the proposed methods. In addition, the rounding error analysis of the proposed methods is studied. The numerical results demonstrate that the proposed methods drastically reduce the computational load without any performance loss in terms of the condition number of the reduced lattice basis matrix.

Overturning of precast RC columns in conditions of moderate ground shaking

  • Kafle, Bidur;Lam, Nelson T.K.;Lumantarna, Elisa;Gad, Emad F.;Wilson, John L.
    • Earthquakes and Structures
    • /
    • v.8 no.1
    • /
    • pp.1-18
    • /
    • 2015
  • A simple method of assessing the risk of overturning of precast reinforced concrete columns is presented in this paper. The displacement-based methodology introduced herein is distinguished from conventional force-based codified methods of aseismic design of structures. As evidenced by results from field tests precast reinforced concrete columns can be displaced to a generous limit without sustaining damage and then fully recover from most of the displacement afterwards. Realistic predictions of the displacement demand of such (rocking) system in conjunction with the displacement capacity estimates enable fragility curves for overturning to be constructed. The interesting observation from the developed fragility curves is that the probability of failure of the precast soft-storey column decreases with increasing size of the column importantly illustrating the "size effect" phenomenon.

Comparison of steels via SMAW and MIG welding methods under industrial loads

  • Soy, Ugur
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.225-232
    • /
    • 2011
  • In this study, the deflection and deformation behaviours of IPN80 steel beam and column were investigated under the different industrial loads. Single-sided welds were applied to IPN80 steel beams using shielded metal arc (SMAW) and metal inert gas welding (MIG) method in the form of T-type. After that, the performance of SMAW and MIG welded joints were identified using beam bending test under 500 and 3000 N loads. SMAW and MIG methods were compared with each other to understand the deflection and deformation behaviours of the welded steel structures. Lower deformation and deflection were obtained in MIG welded steel beams. The results show that, steel beams welded MIG method has higher load capacity than SMAW welded ones. MIG welding method is more reliable than the SMAW method for the combining performance and load capacity.

Shadow Recovery for Column-based Databases (컬럼-기반 데이터베이스를 위한 그림자 복구)

  • Byun, Si-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2784-2790
    • /
    • 2015
  • The column-oriented database storage is a very advanced model for large-volume data transactions because of its superior I/O performance. Traditional data storages exploit row-oriented storage where the attributes of a record are placed contiguously in hard disk for fast write operations. However, for search-mostly data warehouse systems, column-oriented storage has become a more proper model because of its superior read performance. Recently, solid state drive using flash memory is largely recognized as the preferred storage media for high-speed data analysis systems. In this research, we propose a new transaction recovery scheme for a column-oriented database environment which is based on a flash media file system. We improved traditional shadow paging schemes by reusing old data pages which are supposed to be invalidated in the course of writing a new data page in the flash file system environment. In order to reuse these data pages, we exploit reused shadow list structure in our column-oriented shadow recovery(CoSR) scheme. CoSR scheme minimizes the additional storage overhead for keeping shadow pages and minimizes the I/O performance degradation caused by column data compression of traditional recovery schemes. Based on the results of the performance evaluation, we conclude that CoSR outperforms the traditional schemes by 17%.

Retrofit Design of RC Column by Displacement-Based-Design Method (변위기반설계법에 의한 철근콘크리트 기둥의 보강설계)

  • Lim, Cheong-Kweon;Kwon, Min-Ho;Ha, Keum-Hee;Kim, Jin-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2804-2811
    • /
    • 2012
  • In this study, It is developed a retrofitting procedure of RC column with rectangular section to archive the target displacement at failure. Nonlinear behavior of the column is considered as the equivalent linear system. First, target displacement is determined, and then elastic displacement spectrum is constructed to estimate the equivalent natural vibration period of the SDOF system. After natural vibration period is determined, required strength is calculated using secant stiffness based on the mass of system. In accordance with, obtained force-displacement relationship through non-linear fiber based section analysis, retrofit design was carried out to meet required strength. As a result, retrofitted RC column can confirm that the improved seismic performance. It is observed that the proposed design procedure can be applicable to seismic retrofitting design of columns.

Numerical Upwelling Experiment for Optimum Arrangement of Artificial Seamount (용승을 고려한 인공해중산 최적배치 수치실험)

  • Kim, Seong-Hyeon;Kim, Dong-Sun
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.997-1009
    • /
    • 2011
  • In order to estimate volume transport by upwelling for single artificial seamount, same shape and size of artificial seamount already deployed was applied to numerical experiment. The result showed that strong upwelling appeared at front while took place downwelling at rear. The strongest upwelling existed at the top of the artificial seamount. Volume transport by upwelling was computed as 785 m3/s. Column arrangement was applied to two artificial seamount in three cases; case 1) no clearance, case 2) sixty-five meters of clearance as half of artificial seamount's length, and case 3) hundred-thirty meters of clearance as an artificial seamount's length. All cases of column arrangements showed more upwelling volume transport than that of single seamount. Particularly, the case of no clearance calculated as 106% and appeared the most upwelling effect comparing to two other cases. Row arrangement was also applied to two artificial seamount in three cases; case 4) no clearance, case 5) forty meters of clearance as an artificial seamount's width, and case 6) eighty meters of clearance as twice of artificial seamount's width. Upwelling volume transport in case 4 increased 48% than the case of single seamount. Other two cases of 5 and 6 were estimated as 97% increased and more effective than case 4. According to the case experiments, column arrangements show more upwelling volume transport than that of row arrangements. In cases of column arrangements, with decreasing clearance between two seamount, the effect increases while showing maximum value at clearance zero. In cases of row arrangements, on the contrary, with decreasing clearance between two seamount, the effect decreases while showing minimum value at clearance zero. Since simple barotropic condition was considered for this study, further study is necessary by considering baroclinic condition to get close to reality. In conclusion, in deploying artificial seamount, optimal arrangement should be well designed to enhance primary and secondary productivity and to increase the diversity of species as well as reducing time and space.

Effects of Operating Variables on the Conversion of Meta Boric Acid Formation in a Bubble Column Reactor (기포탑 반응기에서 조작변수가 meta 붕산 생성반응 전환율에 미치는 영향)

  • Cho, Soo-Haeng;Do, Jae-Bum;Kang, Y.
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.573-579
    • /
    • 1996
  • Effects of operating variables on the conversion of the formation reaction of meta boric acid from ortho boric acid in a laboratory-scale bubble column reactor were investigated to obtain the basic data which are indispensable for the design, scale-up, control, development and operation of industrial bubble column reactors. Reaction time and pressure, particle size of reactant and gas flow rate were chosen as experimental variables. Effects of the experimental variables on the gas holdup in the bubble column reactor were also discussed in relation to the conversion of reaction. From the results of this study, the optimum conditions were drawn as follows : Reaction time ; 35~40(min), reaction pressure ; 92~95(kPa), particle size ; under $0.6{\times}10^{-3}(m)$, gas flow rate ; 0.07~0.08(m/s).

  • PDF

Structural Performance of High-Strength Concrete-Filled Steel Tube Steel Columns using Different Strength Steels (이종강종을 사용한 고강도 CFT 합성부재의 구조성능)

  • Choi, In Rak;Chung, Kyung Soo;Kim, Jin Ho;Hong, Geon Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.711-723
    • /
    • 2012
  • Structural tests were performed to investigate the structural performance of concrete-filled steel tube column using different strength steels in their flange and web with high-strength steel HSA800 and mild steel SM490, respectively. The test parameters included the strength of column flange and infill concrete, and effect of concrete infill. Connection between different grade steels were welded using the electrode appropriate for mild steel and verified its performance. To evaluate the behavior of test specimens, eccentric loading tests were performed and the results were compared with the prediction by current design codes. Axial load and moment carrying capacity of test specimens increased with the yield strength of compression flange and weld fracture occurred after the specimen shows full strength. The prediction result for axial load-bending moment relationship and effective flexural stiffness gave good agreement with the test result.

Evaluation and modelling of the separation of anthracite in the hindered-settling column

  • Kim, Jeong-Yun;Cho, Hee-Chan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.611-617
    • /
    • 2003
  • This study was performed to develop the method for producing industrial coal sources by cleaning Korean anthracite. Laboratory hindered-settling separation column was set and three coal samples were used for tests. Tests were conducted to evaluate the effects of the major operating variables, teeter water flow rate and relative column pressure (set point). Additional tests were performed to elevate the yield and properties of the products using air bubble injecting process. In results, nice products were obtained with high teeter water flow rate and air bubble injection. Also, model of continuous hindered-settling separation process was established to assist the evaluation of the equipment and several operating variables, such as dispersion, teeter water flow rate, feeding rate, etc.

  • PDF