• Title/Summary/Keyword: industrial chimney

Search Result 20, Processing Time 0.025 seconds

System identification and reliability assessment of an industrial chimney under wind loading

  • Tokuc, M. Orcun;Soyoz, Serdar
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.283-291
    • /
    • 2018
  • This study presents the reliability assessment of a 100.5 m tall reinforced concrete chimney at a glass factory under wind loading by using vibration-based identified modal values. Ambient vibration measurements were recorded and modal values such as frequencies, shapes and damping ratios were identified by using Enhanced Frequency Domain Decomposition (EFDD) method. Afterwards, Finite Element Model (FEM) of the chimney was verified based on identified modal parameters. Reliability assessment of the chimney under wind loading was performed by obtaining the exceedance probability of demand to capacity distribution. Demand distribution of the chimney was developed under repetitive seeds of multivariate stochastic wind fields generated along the height of chimney. Capacity distribution of the chimney was developed by Monte Carlo simulation. Finally, it was found that reliability of the chimney is lower than code suggested limit values.

Some aspects of the dynamic cross-wind response of tall industrial chimney

  • Gorski, Piotr
    • Wind and Structures
    • /
    • v.12 no.3
    • /
    • pp.259-279
    • /
    • 2009
  • The paper is concerned with the numerical study of the cross-wind response of the 295 m-tall six-flue industrial chimney, located in the power station of Belchatow, Poland. The response of the chimney due to turbulent wind flow is caused by the lateral turbulence component and vortex excitation with taking into account motion-induced wind forces. The cross-wind response has been estimated by means of the random vibration approach. Three power spectral density functions suggested by Kaimal, Tieleman and Solari for the evaluation of the lateral turbulence component response are taken into account. The vortex excitation response has been calculated by means of the Vickery and Basu's model including some complements. Motion-induced wind forces acting on a vibrating chimney have been modeled as a nonlinear aerodynamic damping force. The influence of three components mentioned above on the total cross-wind response of the chimney has been investigated. Moreover, the influence of damping ratios, evaluated by Multi-mode Random Decrement Technique, and number of mode shapes of the chimney have been examined. Computer programmes have been developed to obtain responses of the chimney. The numerical results and their comparison are presented.

Effects of blast-induced random ground motions on the stochastic behaviour of industrial masonry chimneys

  • Haciefendioglu, Kemal;Soyluk, Kurtulus
    • Structural Engineering and Mechanics
    • /
    • v.43 no.6
    • /
    • pp.835-845
    • /
    • 2012
  • This paper focuses on the stochastic response analysis of industrial masonry chimneys to surface blast-induced random ground motions by using a three dimensional finite element model. Underground blasts induce ground shocks on nearby structures. Depending on the distance between the explosion centre and the structure, masonry structures will be subjected to ground motions due to the surface explosions. Blast-induced random ground motions can be defined in terms of the power spectral density function and applied to each support point of the 3D finite element model of the industrial masonry system. In this paper, mainly a parametric study is conducted to estimate the effect of the blast-induced ground motions on the stochastic response of a chimney type masonry structure. With this purpose, different values of charge weight and distance from the charge centre are considered for the analyses of the chimney. The results of the study underline the remarkable effect of the surface blast-induced ground motions on the stochastic behaviour of industrial masonry type chimneys.

Numerical modelling for evaluating the TMD performance in an industrial chimney

  • Iban, A.L.;Brownjohn, J.M.W.;Belver, A.V.;Lopez-Reyes, P.M.;Koo, K.
    • Wind and Structures
    • /
    • v.17 no.3
    • /
    • pp.263-274
    • /
    • 2013
  • A numerical technique for fluid-structure interaction, which is based on the finite element method (FEM) and computational fluid dynamics (CFD), was developed for application to an industrial chimney equipped with a pendulum tuned mass damper (TMD). In order to solve the structural problem, a one-dimensional beam model (Navier-Bernoulli) was considered and, for the dynamical problem, the standard second-order Newmark method was used. Navier-Stokes equations for incompressible flow are solved in several horizontal planes to determine the pressure in the boundary of the corresponding cross-section of the chimney. Forces per unit length were obtained by integrating the pressure and are introduced in the structure using standard FEM interpolation techniques. For the fluid problem, a fractional step scheme based on a second order pressure splitting has been used. In each fluid plane, the displacements have been taken into account considering an Arbitrary Lagrangian Eulerian approach. The stabilization of convection and diffusion terms is achieved by means of quasi-static orthogonal subscales. For each period of time, the fluid problem was solved and the geometry of the mesh of each fluid plane is updated according to the structure displacements. Using this technique, along-wind and across-wind effects have been properly explained. The method was applied to an industrial chimney in three scenarios (with or without TMD and for different damping values) and for two wind speeds, showing different responses.

Design of Heating Supply System for Facility House using Industrial Chimney Waste Heat (산업용 굴뚝 폐열을 활용한 시설하우스 난방 공급 시스템 설계)

  • Chang-Jo Lee;Jin-Gwang Koh;Sung-Keun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.661-668
    • /
    • 2023
  • A large amount of fuel is required for heating the agricultural facility house, and many farmhouses are experiencing the burden of heating costs due to the recent increase in fuel prices. This paper proposes a supply system that supports heating of agricultural facility houses located nearby by utilizing industrial chimney waste heat, and analyzes the application and effect of a heating cost reduction model. The system was designed based on the chimney waste heat system, and the facility house heating cost reduction model was applied and effect analysis was performed based on the proposed model. It was confirmed that the high-temperature waste heat from the chimney can be used to supply heating to facility houses in nearby farms. If heating is supplied to large-scale facility houses near industrial complexes, it is expected to contribute to improve productivity and competitiveness of domestic farms.

Dynamic soil-structure interaction studies on 275m tall industrial chimney with openings

  • Jayalekshmi, B.R.;Thomas, Ansu;Shivashankar, R.
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.233-250
    • /
    • 2014
  • In this paper, a three dimensional soil-structure interaction (SSI) is numerically simulated using finite element method in order to analyse the foundation moments in annular raft of tall slender chimney structures incorporating the effect of openings in the structure and the effect of soil flexibility, when the structure-soil system is subjected to El Centro (1940) ground motion in time domain. The transient dynamic analysis is carried out using LS-DYNA software. The linear ground response analysis program ProShake has been adopted for obtaining the ground level excitation for different soil conditions, given the rock level excitation. The radial and tangential bending moments of annular raft foundation obtained from this SSI analysis have been compared with those obtained from conventional method according to the Indian standard code of practice, IS 11089:1984. It is observed that tangential and radial moments increase with the increase in flexibility of soil. The analysis results show that the natural frequency of chimney decreases with increase in supporting soil flexibility. Structural responses increase when the openings in the structure are also considered. The purpose of this paper is to propose the need for an accurate evaluation of the soilstructure interaction forces which govern the structural response.

A comparative study of along and cross-wind responses of a tall chimney with and without flexibility of soil

  • Gorski, Piotr;Chmielewski, Tadeusz
    • Wind and Structures
    • /
    • v.11 no.2
    • /
    • pp.121-135
    • /
    • 2008
  • The paper is concerned with a comparative study of both the along and cross-wind responses of a tall industrial chimney with and without flexibility of soil. The along-wind response has been estimated by means of approaches presented in three Standards: the Polish, the ISO and the Eurocode and by random vibration approach which is outlined below. The cross-wind response has been estimated by means of the three models developed by Vickery and Basu, Ruscheweyh and Flaga and methods presented in Standards: the Polish, the ISO and the Eurocode (Approach 1 and 2). Computer programmes were developed to obtain estimates of responses of a six-flue, 250 m-tall chimney. The analytical results computed according to the methods presented in different standards and random vibration approaches have been compared. Some unexpected conclusions have been observed.

The slenderness effect on wind response of industrial reinforced concrete chimneys

  • Karaca, Zeki;Turkeli, Erdem
    • Wind and Structures
    • /
    • v.18 no.3
    • /
    • pp.281-294
    • /
    • 2014
  • There are several parameters affecting the response of industrial reinforced concrete (RC) chimneys, i.e., the severity of wind and earthquake loads acting to the structure, structural properties such as height and cross section of the chimney, the slenderness property of the structure etc. One of the most important parameter that should be considered while understanding the wind response of industrial RC chimneys is slenderness property. Although there is no certain definition for slenderness effect on these structures, some standards like ASCE-7 define slenderness from different aspects of the structural properties. In the first part of this study, general information about the definition of slenderness in the well-known standards and ten selected industrial RC chimneys are given. In the second part of the study, brief information about wind load standards that are used for calculating wind loads namely ACI 307/98, CICIND 2001, DIN 1056, TS 498 and Eurocode 1 is given. In the third part of the study, calculated wind loads for selected chimneys are represented. In the fourth part of this study, the internal forces obtained from load combinations that are applied to chimneys and some graphs presenting the effect of slenderness on chimneys are given. In the last part of the study, a conclusion and discussion part is taking place.

Response of fiber reinforced plastic chimneys to wind loads

  • Awad, A.S.;El Damatty, A.A.;Vickery, B.J.
    • Wind and Structures
    • /
    • v.3 no.2
    • /
    • pp.83-96
    • /
    • 2000
  • Due to their high corrosion and chemical resistance, fiber reinforced plastics (FRP) are becoming widely used as the main structural material for industrial chimneys. However, no national code currently exists for the design of such type of chimneys. The purpose of this study is to investigate analytically the response of FRP chimneys to wind loads. The classical lamination theory is used to substitute the angle-ply laminate of a FRP chimney with an equivalent orthotropic material that provides the same stiffness. Dynamic wind loads are applied to the equivalent chimney to evaluate its response to both along and across wind loads. A parametric study is then conducted to identify the material and geometric parameters affecting the response of FRP chimneys to wind loads. Unlike the across-wind response, the along-wind tip deflection is found to be highly dependent on the angle of orientation of the fibers. In general, the analysis shows that FRP chimneys are very vulnerable to across-wind oscillations resulting from the vortex shedding phenomenon.

YOLOv5-based Chimney Detection Using High Resolution Remote Sensing Images (고해상도 원격탐사 영상을 이용한 YOLOv5기반 굴뚝 탐지)

  • Yoon, Young-Woong;Jung, Hyung-Sup;Lee, Won-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_2
    • /
    • pp.1677-1689
    • /
    • 2022
  • Air pollution is social issue that has long-term and short-term harmful effect on the health of animals, plants, and environments. Chimneys are the primary source of air pollutants that pollute the atmosphere, so their location and type must be detected and monitored. Power plants and industrial complexes where chimneys emit air pollutants, are much less accessible and have a large site, making direct monitoring cost-inefficient and time-inefficient. As a result, research on detecting chimneys using remote sensing data has recently been conducted. In this study, YOLOv5-based chimney detection model was generated using BUAA-FFPP60 open dataset create for power plants in Hebei Province, Tianjin, and Beijing, China. To improve the detection model's performance, data split and data augmentation techniques were used, and a training strategy was developed for optimal model generation. The model's performance was confirmed using various indicators such as precision and recall, and the model's performance was finally evaluated by comparing it to existing studies using the same dataset.