• 제목/요약/키워드: inductive

검색결과 1,466건 처리시간 0.026초

송전선용 대용량 신호결합장치의 설계 (Design of an Inductive Coupler for Power Transmission line)

  • 김현식;변우봉;김종령;배을록;이동철;이해연;이준희;지민권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.439-440
    • /
    • 2008
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nano-crystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electro-magnetic simulation in this study. Communication speed of 14 Mbps in 600 m communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

  • PDF

귀납적 추론의 과정 분석 (Analysis of Inductive Reasoning Process)

  • 이성근;류희수
    • 대한수학교육학회지:학교수학
    • /
    • 제14권1호
    • /
    • pp.85-107
    • /
    • 2012
  • 본 연구에서는 문제해결에서 귀납적 추론의 과정을 분석하여 귀납적 추론의 단계를 0단계 문제 이해, 1단계 규칙성 인식, 2단계 자료 수집 실험 관찰, 3단계 추측(3-1단계)과 검증(3-2단계), 4단계 발전의 총 5단계로, 귀납적 추론의 흐름은 0단계에서 4단계로의 순차적인 흐름을 포함하여 자신이 찾은 규칙이나 추측에 대하여 반례를 발견하였을 때 대처하는 방식에 따라 다양하게 설정하였다. 또한 초등학교 6학년 학생 4명에 대한 사례 연구를 통하여 연구자가 설정한 귀납적 추론 단계와 흐름의 적절성을 확인하였고 귀납적 추론의 지도를 위한 시사점을 도출하였다.

  • PDF

품질 및 신뢰성 기법에서 연역 및 귀납 추론에 의한 Conjugate 분포의 적용 (Application of Conjugate Distribution using Deductive and Inductive Reasoning in Quality and Reliability Tools)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.27-33
    • /
    • 2010
  • The paper proposes the guidelines of application and interpretation for quality and reliability methodologies using deductive or inductive reasoning. The research also reviews Bayesian quality and reliability tools by deductive prior function and inductive posterior function.

  • PDF

The Study On the Effectiveness of Information Retrieval in the Vector Space Model and the Neural Network Inductive Learning Model

  • Kim, Seong-Hee
    • 정보기술과데이타베이스저널
    • /
    • 제3권2호
    • /
    • pp.75-96
    • /
    • 1996
  • This study is intended to compare the effectiveness of the neural network inductive learning model with a vector space model in information retrieval. As a result, searches responding to incomplete queries in the neural network inductive learning model produced a higher precision and recall as compared with searches responding to complete queries in the vector space model. The results show that the hybrid methodology of integrating an inductive learning technique with the neural network model can help solve information retrieval problems that are the results of inconsistent indexing and incomplete queries--problems that have plagued information retrieval effectiveness.

  • PDF

소형궤도 열차용 유도 전력 전송 시스템 특성해석 (Characteristic Analysis of Inductive Power Transfer System for PRT)

  • 민병훈;이병송
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.35-43
    • /
    • 2007
  • 본 논문에서는 전자 유도 법칙을 이용한 차량용 유도 전력 집전장치가 제안하였으며 전력 전송 특성을 개선하기 위한 전력 집전체의 몇 가지 설계에 관련된 개점을 제시하였다. 또한 다양한 공진 주파수로 동작되는 직렬 공진 컨버터와 연결하여 전력 전송 시스템의 해석을 나타내었다. 동작 주파수와 파라미터의 변동에 대한 시스템의 민감도가 고려되며, 유도 전력 전송 시스템에 있어서 전력은 코일이나 트랙의 형태인 1차 권선을 통하여 하나, 혹은 그 이상의 절연된 급전 코일로 전송된다. 본 논문은 유도전력전송의 집전장치의 구조를 기존변압기와 유사한 등가회로의 파라미터로 구성하고, 공극 및 권선을 고려한 1차, 2차측 파라미터를 설정하여 1차측 급전 주파수의 변화에 따른 집전특성에 대하여 기술하였다.

Feasibility study on the inductive fault current limiting cable

  • Lee, Sang Yoon;Choi, Jongho;Kim, Dong Min;Sim, Kideok;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.24-28
    • /
    • 2013
  • Fault current limiting (FCL) cable is a kind of superconducting cable which has a function of limiting the fault current at the fault of power grid. The superconducting cable detours the fault current through its stabilizer to keep the temperature as low as possible. On the other hands, the FCL cable permits the temperature rise within some acceptable limit and the fault current is limited by the consequent increase of the resistance of superconducting cable. This kind of FCL cable is called 'resistive FCL cable' because it uses resistive impedance to limit the fault current. In this paper, we suggest a novel concept of FCL cable, which is named as 'inductive FCL cable'. The inductive FCL cable is similar as the magnetic shielding fault current limiter in its operating mechanism. The magnetic field of superconducting cable is almost perfectly shielded by the induced current at the shielding layer during its normal operation. However, at the fault condition, quench occurs at the shielding layer by the induced current higher than its critical current and the magnetic field is spread out of the shielding layer. It will induce additional inductive impedance to the superconducting cable and the inductive impedance can be increased more by installing some material with high magnetic susceptibility around the superconducting cable. We examined the feasibility of inductive FCL cable with simple elemental experiments. The current limiting performance of inductive FCL cable was estimated considering an arbitrary power grid and its fault condition.

Practical Bifurcation Criteria considering Inductive Power Pad Losses in Wireless Power Transfer Systems

  • Kim, Minkook;Lee, Jae-Woo;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.173-181
    • /
    • 2017
  • In this paper, the bifurcation criteria for inductive power transfer (IPT) systems is suggested considering the inductive power pad losses. The bifurcation criteria for series-series (SS) and series-parallel (SP) topologies are derived in terms of the main parameters of the IPT system. For deriving precise criteria, power pad resistance is obtained by copper loss calculation and core loss analysis. Utilizing the suggested criteria, possibility of bifurcation occurrence can be predicted in the design process. In order to verify the proposed criteria, 50 W IPT laboratory prototype is fabricated and the feasibilities of the switching frequency and AC load resistance shift to escape from bifurcation are identified.

유도형 변위 센서의 민감도 향상을 위한 형상 최적 설계 (Shape Design Optimization of Inductive Position Sensor to Improve Sensitivity)

  • 홍준희;이동주;신우철
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.250-254
    • /
    • 2001
  • The resolution of analog sensor is determined by its sensitivity and amplitude of noise. This paper presents modeling of inductive gap sensor base on equivalent magnetic circuit and analysis of sensitivity. We can simulate static characteristic of inductive gap sensor using this model. Computer simulation show that sensor's sensitivity is affected by magnetic flux's leakage and fringing, and that they are affected by shape of sensor probe. Base on this, we designed shape of inductive position sensor probe.

  • PDF

고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석 (The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting)

  • 송재주;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF