• Title/Summary/Keyword: induced voltage

Search Result 1,158, Processing Time 0.023 seconds

Measurement and Analysis of Antenna Induced Voltage for Tactical Mobile Wireless Communication System under HEMP Environment (HEMP 상황 하 전술기동무선통신체계 안테나 유도전압 측정 및 분석)

  • Park, Kyoung-Je;Jeong, Kil-Soo;Kim, Jung-Sup;Park, Yong-Woo;Park, Jae-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.2
    • /
    • pp.33-40
    • /
    • 2021
  • The situation of high-altitude electromagnetic pulses (HEMP) arises from high-altitude nuclear explosions. The HEMP situation can be simulated through the threat level investigation (TLI). In this paper, the induced voltage according to the antenna type of the tactical mobile radio communication system was measured and analyzed by TLI. Under the influence of HEMP, electronic equipment can be paralyzed or damaged. HEMP protection filters are commercially available for power lines and signal lines. However, commercialization of HEMP filters for antennas is insufficient, and even some of them exist for lightning protection. In order to make an appropriate HEMP protection filter according to the frequency and type of the antenna, the induced voltage was measured and the maximum induced voltage was analyzed through extrapolation. It was found that the measured induced voltage decreased as the frequency increased, such as in the HF, VHF and UHF bands of the measurement results.

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation (전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

Characteristics of Trap in the Thin Silicon Oxides with Nano Structure

  • Kang, C.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.6
    • /
    • pp.32-37
    • /
    • 2003
  • In this paper, the trap characteristics of thin silicon oxides is investigated in the ULSI implementation with nano structure transistors. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The transient current was caused by the tunnel charging and discharging of the stress generated traps nearby two interfaces. The stress induced leakage current will affect data retention in electrically erasable programmable read only memories. The oxide current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 113.4nm and 814nm, which have the gate area 10$\^$-3/ $\textrm{cm}^2$. The stress induced leakage currents will affect data retention, and the stress current and transient current is used to estimate to fundamental limitations on oxide thicknesses.

Wind-rain-induced vibration test and analytical method of high-voltage transmission tower

  • Li, Hong-Nan;Tang, Shun-Yong;Yi, Ting-Hua
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.435-453
    • /
    • 2013
  • A new computational approach for the rain load on the transmission tower is presented to obtain the responses of system subjected to the wind and rain combined excitations. First of all, according to the similarity theory, the aeroelastic modeling of high-voltage transmission tower is introduced and two kinds of typical aeroelastic models of transmission towers are manufactured for the wind tunnel tests, which are the antelope horn tower and pole tower. And then, a formula for the pressure time history of rain loads on the tower structure is put forward. The dynamic response analyses and experiments for the two kinds of models are carried out under the wind-induced and wind-rain-induced actions with the uniform and turbulent flow. It has been shown that the results of wind-rain-induced responses are bigger than those of only wind-induced responses and the rain load influence on the transmission tower can't be neglected during the strong rainstorm. The results calculated by the proposed method have a good agreement with those by the wind tunnel test. In addition, the wind-rain-induced responses along and across the wind direction are in the same order of response magnitude of towers.

A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation (방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF

Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances (가정용 전기기구에서 발생하는 자장과 유도전압의 측정과 분석)

  • 이복희;이동문;장영태;장근철;엄주홍;강성만;이승칠;박정용
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14" television set, and their values are 2.1 [$\mu$Tp-p]and 140 [mVp-p]at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17" monitor for personal computer and the measured data was approximately 560[mV/$\mu$T]at the same distance. distance.

Experimental Investigation on Induced Voltage of the Secondary Conductors in Linear Induction Motor with Cage-type Secondary Fed by PWM Inverter (PWM 인버터로 구동되는 농형 선형유도전동기의 2차측 도체 전압 특성)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.21-24
    • /
    • 2002
  • In this paper, induced voltages of the secondary conductors of a linear induction motor(LIM) with cage-type secondary are measured and analyzed when the LIM is fed by PWM inverter. The attenuation constant of the induced voltage of the secondary conductors near entry and exit zones of the the travelling magnetic field are determined from the experiment results.

  • PDF

Study on the Countermeasure to Induced AC Voltage for Protection to Corrosion of Underground Pipelines (지하 매설 배관의 부식방지를 위한 교류유도 저감대책에 관한 연구)

  • Kim, Dae-Kyeong;Bae, Jeong-Hyo;Lee, Hyun-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.803-806
    • /
    • 1997
  • The AC induced voltage on underground pipelines not only do harm to workers and instruments, but also cause big trouble in some case. This paper gives the mechanisms, examples, and countermeasure for the AC induced voltages which are caused by the resistive coupling between the grounding system of the 22.9kV distribution power system and the underground pipeline.

  • PDF

Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line (축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.