• Title/Summary/Keyword: induced ground

Search Result 906, Processing Time 0.035 seconds

Response of Open-ended Pipe Pile Foundation at Offshore Sites to Seaquake Induced by the Vertical Seismic Excitation of the Seafloor (해저면의 수직 지진 진동에 의해 유발된 해진에 대한 해상 개단 강관 말뚝 기초의 거동)

  • 최용규;남문석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • During an earthquake, there are three main components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation induced by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the soil plugs in open-ended pie piles installed at offshore sites. In this study, seaquake excitation induced by the vertical ground shaking was simulated by pulsing the water pressure at the seabed. During a seaquake, due to the induced excess porewater pressure and pressure gradients in the soil, the capacity of open-ended pipe piles installed in a simulated sea depth of greate than 220 m was reduced serevely and the soil plugging resistance was degraded by more than 80% The soil plug was failed because of eh upward seepage forces that developed in the soil plug due to excess pore water pressure produced in the bottom of the soil plug during the seaquake, The compressive capacity of ar open-ended pile in a simulated sea depth of less than 220 m was reduced only by about 10% and the soil plug resistance was degraded by less than 5%.s than 5%.

  • PDF

Field Tests Investigating the Ground Borne Vibration Induced by Underground Railway Tunnel (터널 내 열차주행으로 인한 지반진동 현장측정시험)

  • Ahn, Sung-Kwon;Bang, Eun-Seok;Lee, Bae
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.208-213
    • /
    • 2010
  • This paper describes the instruments used, and the test procedures adopted, and the findings obtained from a research project aiming to investigate, via full-scale field tests, the ground borne vibration caused by underground railway tunnel constructed in hard rock. The ground borne vibration induced by high-speed trains (i.e. the Korea Train eXpress (KTX) services) with a speed of approximately 200km/hr was measured inside the borehole constructed in the close proximity to the KTX tunnel using 3-component borehole seismographs in order to investigate the wave propagation of ground borne vibration. This paper also discusses the limitation associated with the current practice of measuring ground borne vibration using conventional borehole seismograph.

New methodology to prevent blasting damages for shallow tunnel

  • Ozacar, Vehbi
    • Geomechanics and Engineering
    • /
    • v.15 no.6
    • /
    • pp.1227-1236
    • /
    • 2018
  • From all of the environmental problems, blast-induced vibrations often cause concern to surrounding residents. It is often claimed that damage to building superstructures is due to blasting, and sometimes the building owner files a lawsuit against the company that perform blasting operations. The blast-vibration problem has been thoroughly investigated in the past and continues to be the subject of ongoing research. In this study, a tunnel construction has been performed by a construction company, according to their contract they must have used drilling & blasting method for excavation in tunnel inlet and outlet portal. The population is very condensed with almost tunnel below in the vicinity houses of one or two floors, typically built with stone masonry and concrete. This situation forces the company to take extreme precautions when they are designing blasts so that the blast effects, which are mainly vibration and aerial waves, do not disturb their surrounding neighbors. For this purpose, the vibration measurement and analysis have been carried out and a new methodology in minimizing the blast induced ground vibrations at the target location, was also applied. Peak particle velocity and dominant frequencies were taken into consideration in analyzing the blast-induced ground vibration. The methodology aims to employ the most suitable time delays among blast-hole groupings to render destructive interference of surface waves at the target location.

Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation (전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

Study of Influence Factors for Prediction of Ground Subsidence Risk

  • Park, Jin Young;Jang, Eugene;Ihm, Myeong Hyeok
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This Analyzed case study of measuring displacement, implemented laboratory investigation, and in-situ testing in order to interpret ground subsidence risk rating by excavation work. Since geological features of each country are different, it is necessary to objectify or classify quantitatively ground subsidence risk evaluation in accordance with Korean ground character. Induced main factor that could be evaluated and used to predicted ground subsidence risk through literature investigation and analysis study on research trend related to the ground subsidence. Major factors of ground subsidence might be classified by geological features as overburden, boundary surface of ground, soil, rock and water. These factors affect each other differently in accordance with type of ground that's classified soil, rock, or complex. Then rock could be classified including limestone element or not, also in case of the latter it might be classified whether brittle shear zone or not.

A practical coherency model for spatially varying ground motions

  • Yang, Qing-Shan;Chen, Ying-Jun
    • Structural Engineering and Mechanics
    • /
    • v.9 no.2
    • /
    • pp.141-152
    • /
    • 2000
  • Based on the discussion about some empirical coherency models resulted from earthquake-induced ground motion recordings at the SMART-1 array in Taiwan, and a heuristic model of the coherency function from elementary notions of stationary random process theory and a few simplifying assumptions regarding the propagation of seismic waves, a practical coherency model for spatially varying ground motions, which can be applied in aseismic analysis and design, is proposed, and the regressive coefficients are obtained using least-square fitting technique from the above recordings.

Prediction and Control of the Propogation of Underground Train Systems-induced Ground Vibration: State of the Art (지하철 차량운행에 의한 진동영향 평가: State of the Art)

  • Lee, In-Mo;Choe, Sang-Sun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.06a
    • /
    • pp.73-82
    • /
    • 1993
  • Ground-borne vibration is one of the main causes of environmental impact from subway systems. The vibration resulting from track-train interaction is transuutted through the tunnel structure and the surrounding ground to adjacent buildings. This paper provides a summary of proposed noise and vibration criteria, a review of the ground vibration propagation mechanism and the theoretical isolation effectivenesss of each of the following underground transit systems : track, tunnel and vehicle itself.

  • PDF

Seismic collapse safety of high-rise RC moment frames supported on two ground levels

  • Wu, Yun-Tian;Zhou, Qing;Wang, Bin;Yang, Yeong-Bin;Lan, Tian-Qing
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.349-360
    • /
    • 2018
  • Reinforced concrete (RC) moment frames supported on two ground levels have been widely constructed in mountainous areas with medium to high seismicity in China. In order to investigate the seismic collapse behavior and risk, a scaled frame model was tested under constant axial load and reversed cyclic lateral load. Test results show that the failure can be induced by the development of story yielding at the first story above the upper ground. The strong column and weak beam mechanism can be well realized at stories below the upper ground. Numerical analysis model was developed and calibrated with the test results. Three pairs of six case study buildings considering various structural configurations were designed and analyzed, showing similar dynamic characteristics between frames on two ground levels and flat ground of each pair. Incremental dynamic analyses (IDA) were then conducted to obtain the seismic collapse fragility curves and collapse margin ratios of nine analysis cases designated based on the case study buildings, considering amplification of earthquake effect and strengthening measures. Analysis results indicate that the seismic collapse safety is mainly determined by the stories above the upper ground. The most probable collapse mechanism may be induced by the story yielding of the bottom story on the upper ground level. The use of tie beam and column strengthening can effectively enhance the seismic collapse safety of frames on two ground levels.

A Case Study of Building Damage Risk Assessment Due to the Strutted Excavation: Design Aspects (지보굴착에 따르는 인접건물의 손상위험도 평가사례: 설계단계)

  • Lee Sun-Jae;Song Tae-Won;Lee Youn-Sang;Song Young-Han;Kim Jae-Kwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.99-112
    • /
    • 2005
  • The ground excavation in the urban area induces in general ground movement and subsequent damage on the adjacent building structures. So the essentials in the designing stage are the prediction of ground movement induced by the ground excavation and the damage risk assessment of buildings adjacent to the excavation. A propsed prediction method of the ground movement induced by the strutted excavation has been studied with due consideration of the existing ground movement prediction methods. A building damage risk assessment method based on the angular distortion and the horizontal strain derived from the green-field ground movement is also proposed. These methods have been applied successfully in the on-going deep excavation project in Singapore.

Permanent Ground Deformation induced by Christchurch Earthquake and Estimation of Underground Water Pipeline Performance in New Zealand (뉴질랜드 크라이스트처어치 지진에 의해 발생된 영구지반변형과 매설된 상수도관 성능평가)

  • Jeon, Sang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4201-4207
    • /
    • 2015
  • In this study, the performance of underground water pipeline system affected by earthquakes is examined by using data acquired after MW 6.2 February 22, 2011 earthquake in Christchurch, NZ. Water pipeline repair rates, expressed as repairs/km, for different types of pipe are evaluated inside the areas of which liquefaction induced by permanent ground deformation was observed and assessed relative to differential settlement and lateral ground strain, calculated from high resolution LiDAR data acquired before and after each seismic event. The earthquake performance of underground water pipeline systems associated with permanent ground deformation is summarized in this paper. The results show that highly ductile polyethylene water pipelines has a high earthquake performance.