• 제목/요약/키워드: induced electric field

검색결과 456건 처리시간 0.024초

진공 인터럽터의 3차원 유한요소해석 (Three-Dimensional Finite Element Analysis of a Vacuum Interrupter)

  • 최승길;강형부
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.693-698
    • /
    • 1999
  • Vacuum interrupters have a special asymmetric electrode structure to generate an magnetic field and consequently to increase the interrupting ability. Accordingly 2-dimensional analysis has a large analysis error because radial flux can not be considered. In this paper, in order to analyse the electric field distribution of a vacuum interrupter with arc shield more accurately, 3-dimensional finite element method(FEM) is used. The induced electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to the fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results also show that the induced potential of shield causes electric field distortion so that the maximum value of electric field in a vacuum interrupter with arc shield is higher than that without one.

  • PDF

전단 유동 하에서 전기유변유체의 과도응답 특성 (Transient Response of an Electrorheological Fluid in Shear Flow)

  • 최병하;남윤주;박명관
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

Effective Periodic Poling in Optical Fibers

  • Kim, Jong-Bae;Ju, Jung-Jin;Kim, Min-Su;Seo, Hong-Seok
    • ETRI Journal
    • /
    • 제26권3호
    • /
    • pp.277-280
    • /
    • 2004
  • The distributions of electric field and induced second-order nonlinearity are analyzed in the periodic poling of optical fibers. A quasi-phase matching efficiency for the induced nonlinearity is calculated in terms of both the electrode separation distance between the applied voltage and generalized electrode width for the periodic poling. Our analysis of the quasi-phase matching efficiency implies that the conversion efficiency can be enhanced through adjusting the separation distance, and the electrode width can be maximized if the electrode width is optimized.

  • PDF

철도용 무선전력전송시스템의 급전선로와 레일유기전압의 관계 (Relation between Induced Voltage of Rail and Feeding Line of Wireless Power Transfer System for Railway Application)

  • 김재희;박찬배;정신명;이승환;이병송;이준호;이수길
    • 한국철도학회논문집
    • /
    • 제17권4호
    • /
    • pp.228-232
    • /
    • 2014
  • 철도의 무선전력전송 시스템을 구현하는데 있어 급전선로에서 생성된 자기장은 레일에 유기전압을 형성한다. 레일의 유기전압은 궤도회로의 동작 및 안전사고에 영향을 줄 수 있기 때문에 최소화하는 것이 필요하다. 본 논문에서는 3가지 무선전력전송 선로에 대해서 레일에 형성되는 유기전압의 관계를 시뮬레이션을 통하여 살펴보고 레일 유기전압을 줄이기 위한 급전선로의 자기장 분포를 제시한다.

지표면 위에 한쪽 면이 도체로 된 손실 유전체 슬랩 속의 다이폴 전원에 의한 동일면상의 전계 (An electric field induced on the same plane by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth)

  • 박동국;라정웅
    • 전자공학회논문지A
    • /
    • 제33A권12호
    • /
    • pp.9-15
    • /
    • 1996
  • An electric field induced by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth is calculated by anumerical method. the calcualtion is peformed on the plane which is parallel to the conductor plane and containing the point dipole soruce. Computed S$_{21}$ values of two parallel planar dipole antennas and two collinear planar dipole antennas are compared against each other, as well as the electic field magnitudes in those arrangements.

  • PDF

분역회전이 강유전체 세라믹내의 균열성장에 미치는 영향 (Effect of Domain Switching on Crack Growth in Ferroelectric Ceramics)

  • 정경문;박재연;범현규
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.142-149
    • /
    • 2003
  • Domain switching effect on crack growth in ferroelectric ceramics under combined electric and mechanical loading is investigated. The shape and size of the switching zone is shown to depend strongly on the relative magnitude between the applied electric field and stress field as well as on the ratio of the coercive electric field to the yield electric field. The toughening mechanism is thought to be ferroelectric domain switching leading to the development of a process zone around the crack. Crack-tip stress intensity factor induced by domain switching for the steady state crack growth is numerically obtained.

PMN-PZ-PT 세라믹스를 이용한 적층형 액츄에이터의 변위특성 (Electric-Field-Induced Strain Properties of Multi Layer Ceramic Actuator Using PMN-PZ-PT Ceramics)

  • 하문수;정순종;고중혁;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.620-623
    • /
    • 2003
  • Non-linear behaviors of multilayer piezoelectric ceramic actuator (MCA) were investigated under electrical and mechanical stress. DC 100 V bias was applied to the MCA to obtain displacement. Laser vibrometer, which using Doppler effect, was employed to characterize displacement caused by $d_{33}$ mode of MCA. To understand this non-linear behavior of MCA, displacement was measured and compared under different load states. By increasing load, electric field-induced strain and piezoelectric constant($d_{33}$) of MCA was decreased. We attribute this phenomenon to the domain wall motion and depoling of MCA under heavy load.

  • PDF

Electric-Field Induced Degradation of Ionic Solids

  • Chun, Ja-Kyu;Yoo, Han-Ill
    • 한국세라믹학회지
    • /
    • 제49권1호
    • /
    • pp.48-55
    • /
    • 2012
  • Degradation of performance and life time of a functional material or device thereof is induced, to a great extent, by mass transfer in the material that is driven by various thermodynamic forces imposed intentionally or accidentally during its operation or service. The forces are any gradient of intensive thermodynamic variables, component chemical potentials, electrical potential, temperature, stresses, and the like. This paper reviews electric-field induced degradation phenomena in ionic solid compounds including insulation resistance degradation, crystal shift, microstructural alterations, compositional unmixing, and compound decomposition. Their inner workings are also discussed qualitatively.

PZN-BT-PT 세라믹스를 이용한 전왜 BUZZER의 음향 특성 (Acoustic Properties of Electrostrictive Buzzer Using PZN-BT-PT Ceramics)

  • 유준현;김현재;박창엽
    • 대한전기학회논문지
    • /
    • 제41권1호
    • /
    • pp.50-55
    • /
    • 1992
  • Piezoelectric Buzzer which has been generally used requires about 30kV/cm poling process and has the aging effects. In this study, 0.85 PZN - 0.10 BT - 0.05 PT system ceramics with additives of 0 - 2 wt% YS12TOS13T were fabricated and investigated on electromechanical coupling coefficient(kS1pT), electric field induced charge coefficient(dS131T), and sound level. As the results, in the 0.4 wt% YS12TOS13T added composition ceramics compared with the basic, kS1pT was increased from 0.355 to 0.39 and induced piezoelectric d constant increased from 204 to 220 x 10S0-12T (C/N) and sound level of electrostrictive Buzzer has the highest value of 71.5 dB under 8kV/cm bias electric field.

  • PDF

유전율 및 도전율을 고려한 765㎸ 송전선하의 인체 유도 전계 해석 (Induced Electric Field Analysis of Human under the 765 kV Transmission Line Considering Permittivity and Conductivity)

  • 민석원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권6호
    • /
    • pp.341-345
    • /
    • 2000
  • This paper analysed the induced electric field of human body under the 765 kV transmission line considering permittivity and conductivity. As permittivity of human body is very high as 106 at 60 Hz, special numerical computation technique is Surface Charge Method(SCM) for composite media with extremely different properties is applied to reduce calculation error of induced electric field inside the human body.

  • PDF