• 제목/요약/키워드: induced earthquake

검색결과 377건 처리시간 0.022초

지하철 진동이 구조물에 미치는 영향분석 모델 (MODEL FOR SUBWAY-INDUCED STRUCTURAL VIBRATION)

  • 김희철;이동근;민경원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.199-204
    • /
    • 1993
  • Noise and vibration induced by subway operation are one of the major factor that annoying residents living near the. railway. In general, lateral vibration was the major concern when we are considering vibration of the building. Since the energy due to earthquake is enormous it affects wide area. However, the vertical vibration became a major concern in considering the vibration induced by subway because relatively smaller energy affects only nearby areas than that of earthquake. Analysis model of the structure for the vertical vibration should consider the effect of beam vibration. Thus, the model of the structure for the lateral vibration can not be applied. Appropriate analysis model which can consider the inertia force of the beam is necessary when analyzing a structure for the vertical vibration. Modeling technique for the vertical vibration analysis of structures has been studied on this paper. It is recommeneded to use 2 or more elements for columns and to use 3 or more elements for beams when analyzing structures for vertical vibration induced by subway.

  • PDF

Seismic vulnerbility analysis of Bankstown's West Terrace railway bridge

  • Mirza, Olivia;Kaewunruen, Sakdirat;Galia, Darren
    • Structural Engineering and Mechanics
    • /
    • 제57권3호
    • /
    • pp.569-585
    • /
    • 2016
  • This paper highlights a case study that investigates the behaviour of existing bridge, West Terrace Bridge, induced by horizontal seismic loading. Unfortunately the lack of past information related to seismic activity within the NSW region has made it difficult to understand better the capacity of the structure if Earthquake occurs. The research was conducted through the University of Western Sydney in conjunction with Railcorp Australia, as part of disaster reduction preparedness program. The focus of seismic analyses was on the assessment of stress behaviour, induced by cyclic horizontal/vertical displacements, within the concrete slab and steel truss of the bridge under various Earthquake Year Return Intervals (YRI) of 1-100, 1-200, 1-250, 1-500, 1-800, 1-1000, 1-1500, 1-2000 and 1-2500. Furthermore the stresses and displacements were rigorously analysed through a parametric study conducted using different boundary conditions. The numerical analysis of the concrete slab and steel truss were performed through the finite element software, ABAQUS. The field measurements and observation had been used to validate the results drawn from the finite element simulation. It was illustrated that under a YRI of 1/1000 the bottom chord of the steel truss failed as the stress induced surpassed the ultimate stress capacity and the horizontal displacement exceeded the allowable displacement measured in the field observations whereas the vertical displacement remained within the previously observed limitations. Furthermore the parametric studies in this paper demonstrate that a change in boundary conditions alleviated the stress distribution throughout the structure allowing it to withstand a greater load induced by the earthquake YRI but ultimately failed when the maximum earthquake loading was applied. Therefore it was recommended to provide a gap of 50mm on the end of the concrete slab to allow the structure to displace without increasing the stress in the structure. Finally, this study has proposed a design chart to showcase the failure mode of the bridge when subjected to seismic loading.

Earthquake-induced pounding between the main buildings of the "Quinto Orazio Flacco" school

  • Fiore, Alessandra;Monaco, Pietro
    • Earthquakes and Structures
    • /
    • 제1권4호
    • /
    • pp.371-390
    • /
    • 2010
  • Historical buildings in seismically active regions are severely damaged by earthquakes, since they certainly were not designed by the original builders to withstand seismic effects. In particular the reports after major ground motions indicate that earthquake-induced pounding between buildings may lead to substantial damage or even collapse of colliding structures. The research on structural pounding during earthquakes has been recently much advanced, although most of the studies are conducted on simplified single degree of freedom systems. In this paper a detailed pounding-involved response analysis of three adjacent structures is performed, concerning the main bodies of the "Quinto Orazio Flacco" school. The construction includes a main masonry building, with an M-shaped plan, and a reinforced concrete building, separated from the masonry one and realized along its free perimeter. By the analysis of the capacity curves obtained by suitable pushover procedures performed separately for each building, it emerges that masonry and reinforced concrete buildings are vulnerable to earthquake-induced structural pounding in the longitudinal direction. In particular, due to the geometric configuration of the school, a special case of impact between the reinforced concrete structure and two parts of the masonry building occurs. In order to evaluate the pounding-involved response of three adjacent structures, in this paper a numerical procedure is proposed, programmed using MATLAB software. Both a non-linear viscoelastic model to simulate impact and an elastic-perfectly plastic approximation of the storey shear force-drift relation are assumed, differently from many commercial softwares which admit just one non-linearity.

부동침하 영향을 고려한 원형 배수지 구조의 3차원 모델링 지진 해석 (Three-dimensional Modeling Seismic Analysis of Circular Water Reservoirs considering Differential Settlement Effects)

  • 이상열;최형배;안광식;정교철
    • 지질공학
    • /
    • 제31권1호
    • /
    • pp.43-53
    • /
    • 2021
  • 본 연구에서는 부동침하 영향을 고려하여 지진 하중을 받는 1,300 ton 규모의 스테인리스 배수지 구조에 대한 3차원 유한요소 해석을 수행하였다. 1,000 ton 규모 이상의 대용량에 대한 지진하중은 한국표준 규격 규정으로부터 확장하여 산정하였다. 부동침하가 발생한 배수지는 특히 지진하중에 대하여 구조적 거동에 중요한 영향이 발생할 수 있다. 다양한 하중 조합에 대하여 정상상태의 경우, 침하가 고려된 경우, 그리고 수평으로 보강된 경우에 대한 응력 및 변위 분포의 변화를 도출하였다. 수치해석 결과로부터 부동침하가 발생된 배수지는 지진하중 조합에 대하여 최대 변위가 크게 증가하게 됨을 확인할 수 있었다.

액상화 영구지반변형에 의한 라이프라인 구조물의 횡방향 거동에 관한 연구 (A Study on transverse Behavior of Lifeline System Due to Liquefaction-induced Permanent Ground Displacement)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.369-376
    • /
    • 1998
  • The purpose of the present study is to analyze the response of pipelines subjected to liquefaction-induced permanent ground displacement and to discuss the failure prediction of domestic waterway pipelines. Initially here, characteristics of liquefaction are reviewed and then permanent ground displacement is investigated base on previous earthquake hazard cases. Next, considering the distribution of the transverse permanent ground displacement and equivalent spring constant effect, formulas obtained by a beam theory are established to analyze continuous pipelines. This analysis was performed without consideration of axial effects. So the finite element analysis was used in order to consider the axial stiffness of soil. As a result, degree of liquefaction, width of deformed ground and axial stiffness are crucial points for evaluation the failure of pipelines subjected to permanent ground displacement.

  • PDF

A substructure formulation for the earthquake -induced nonlinear structural pounding problem

  • Shi, Jianye;Bamer, Franz;Markert, Bernd
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.101-113
    • /
    • 2019
  • Earthquake-induced pounding is one of the major reasons for structural failure in earthquake prone cities. An accurate description of the pounding phenomenon of two buildings requires the consideration of systems with a large number of degrees of freedom including adequate contact impact formulations. In this paper, firstly, a node to surface formulation for the realization of state-of-the-art pounding models for structural beam elements is presented. Secondly, a hierarchical substructure technique is introduced, which is adapted to the structural pounding problem. The numerical accuracy and efficiency of the method, especially for the contact forces, are verified on an academic example, applying four different impact elements. Error estimations are carried out and compared with the classical modal truncation method. It is demonstrated that the hierarchical substructure method is indeed able to significantly speed up the numeric integration procedure by preserving a required level of accuracy.

MOGA-Based Structural Design Method for Diagrid Structural Control System Subjected to Wind and Earthquake Loads

  • Kim, Hyun-Su;Kang, Joo-Won
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1598-1606
    • /
    • 2018
  • An integrated optimal structural design method for a diagrid structure and control device was developed. A multi-objective genetic algorithm was used and a 60-story diagrid building structure was developed as an example structure. Artificial wind and earthquake loads were generated to assess the wind-induced and seismic responses. A smart tuned mass damper (TMD) was used as a structural control system and an MR (magnetorheological) damper was employed to develop a smart TMD (STMD). The multi-objective genetic algorithm used five objectives including a reduction of the dynamic responses, additional stiffness and damping, mass of STMD, capacity of the MR damper for the integrated optimization of a diagrid structure and a STMD. From the proposed method, integrated optimal designs for the diagrid structure and STMD were obtained. The numerical simulation also showed that the STMD provided good control performance for reducing the wind-induced and seismic responses of a tall diagrid building structure.

뉴질랜드 기준에서의 제한된 연성의 RC 구조물 내진설계 (Seismic Design of Reinforced Concrete Structures of Limited Ductility in New Zealand Standard)

  • 이한선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.288-295
    • /
    • 2000
  • As the level of earthquake intensity in Korea is considered to be moderate, some structures or structural elements may be subjected to the reduced ductility demand, in contrast to the structures in high seismicity, due to the large inherent strength induced by gravity loads. New Zealand Standard(NZS) deals with these structures within the category of structures of limited ductility. This paper briefly reviews the concept of structures of limited ductility in NZS, and its applicability to Korean case. A structural wall system which is used as the structural system for typical apartments is taken as an example for the illustration.

  • PDF

Structural Integrity of PWR Fuel Assembly for Earthquake

  • Jhung, M.J.
    • Nuclear Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.212-221
    • /
    • 1998
  • In the present study, a method for the dynamic analysis of a reactor core is developed. Peak responses for the motions induced from earthquake are obtained for a core model. The dynamic responses such as fuel assembly shear force, bending moment, axial force and displacement, and spacer grid impact loads are investigated. Prediction of fuel assembly stress during an earthquake requires development of a fuel assembly stress analysis model capable of interfacing with the models and results discussed in the dynamic analysis of a reactor core. This analysis uses beam characteristics which describe the overall fuel assembly response. The stress analysis method and its application for the case of an increased seismic level are also presented.

  • PDF

Axial response of PWR fuel assemblies for earthquake and pipe break excitations

  • Jhung, Myung J.
    • Structural Engineering and Mechanics
    • /
    • 제5권2호
    • /
    • pp.149-165
    • /
    • 1997
  • A dynamic time-history analysis of the coupled internals and core in the vertical direction is performed as a part of the fuel assembly qualification program. To reflect the interaction between the fuel rods and grid cage, friction element is developed and is implemented. Also derived here is a method to calculate a hydraulic force on the reactor internals due to pipe break. Peak responses are obtained for the excitations induced from earthquake and pipe break. The dynamic responses such as fuel assembly axial forces and lift-off characteristics are investigated.