Browse > Article
http://dx.doi.org/10.12989/sem.2016.57.3.569

Seismic vulnerbility analysis of Bankstown's West Terrace railway bridge  

Mirza, Olivia (School of Computing, Engineering & Mathematics, Western Sydney University)
Kaewunruen, Sakdirat (Birmingham Centre for Railway Research and Education, School of Civil Engineering, the University of Birmingham)
Galia, Darren (Marten and Associate)
Publication Information
Structural Engineering and Mechanics / v.57, no.3, 2016 , pp. 569-585 More about this Journal
Abstract
This paper highlights a case study that investigates the behaviour of existing bridge, West Terrace Bridge, induced by horizontal seismic loading. Unfortunately the lack of past information related to seismic activity within the NSW region has made it difficult to understand better the capacity of the structure if Earthquake occurs. The research was conducted through the University of Western Sydney in conjunction with Railcorp Australia, as part of disaster reduction preparedness program. The focus of seismic analyses was on the assessment of stress behaviour, induced by cyclic horizontal/vertical displacements, within the concrete slab and steel truss of the bridge under various Earthquake Year Return Intervals (YRI) of 1-100, 1-200, 1-250, 1-500, 1-800, 1-1000, 1-1500, 1-2000 and 1-2500. Furthermore the stresses and displacements were rigorously analysed through a parametric study conducted using different boundary conditions. The numerical analysis of the concrete slab and steel truss were performed through the finite element software, ABAQUS. The field measurements and observation had been used to validate the results drawn from the finite element simulation. It was illustrated that under a YRI of 1/1000 the bottom chord of the steel truss failed as the stress induced surpassed the ultimate stress capacity and the horizontal displacement exceeded the allowable displacement measured in the field observations whereas the vertical displacement remained within the previously observed limitations. Furthermore the parametric studies in this paper demonstrate that a change in boundary conditions alleviated the stress distribution throughout the structure allowing it to withstand a greater load induced by the earthquake YRI but ultimately failed when the maximum earthquake loading was applied. Therefore it was recommended to provide a gap of 50mm on the end of the concrete slab to allow the structure to displace without increasing the stress in the structure. Finally, this study has proposed a design chart to showcase the failure mode of the bridge when subjected to seismic loading.
Keywords
railway bridge; seismic analysis; vulnerability; Earthquakes; ballast-top bridge;
Citations & Related Records
연도 인용수 순위
  • Reference
1 AISC (2005), American Institute of Steel Construction's Specification for structural steel building, Chicago, Illinois USA.
2 Baskar, K., Shanmugam, N.E. and Thevendran, V. (2002), "Finite element analysis of steel-concrete composite plate girder", J. Struct. Eng., 128(9), 1158-1168.   DOI
3 Carreira, D. and Chu, K. (1985), "Stress-strain relationship for plain concrete in compression", ACI Struct. J., 82(11), 797-804.
4 Griffin, D.W.P., Mirza, O., Kwok, K. and Kaewunruen, S., (2014b), "Composite slabs for railway construction and maintenance: a mechanistic review", IES J. Civil Struct. Eng., 7(4), 243-262.
5 Griffin, D.W.P., Mirza, O., Kwok, K. and Kaewunruen, S. (2015), "Finite element modelling of modular precast composites for railway track support structure-A battle to save Sydney Harbour Bridge", Aus. J. Struct. Eng., 16(2), 150-168.   DOI
6 Gibson, G. (2010), "Earthquake risk in australia", Australia Planner, 47(1), 57.
7 Légeron, F., Paultre, P. and Mazars, J. (2005), "Damage mechanics modeling of nonlinear seismic behavior of concrete structures", J. Struct. Eng., 131(6), 946-955.   DOI
8 Leonard, M. and Luntz, S. (2007), "Earthquake predictions in Australia", 78, 31-35.
9 Leonard, M., Clark, D., Collins, C. and McPherson, A. (2012), "The 2012 Australian seismic hazard mapsource zones and parameterisation", Proceedings of Australian Earthquake Engineering Society Conference, Barossa Valley, South Australia, November.
10 Liang, Q.Q., Uy, B., Bradford, M.A. and Ronagh, H.R. (2005), "Strength analysis of steel-concrete composite beams in combined bending and shear", ASCE J. Struct. Eng., 131(10), 1593-600.   DOI
11 Loh, H. Y., Uy, B. and Bradford, M. A. (2003), "The effects of partial shear connection in the hogging moment region of composite beams Part II - analytical study", J. Constr. Steel Res., 60, 921-962.
12 McCue, K., Gibson, G., Love, D. and Cranswick, E. (2008), "Engineering for earthquakes in Australia", Aus. J. Struct. Eng., 8(1), 1.   DOI
13 Mirza, O. (2008), "Behaviour and design of headed stud shear connectors in composite steel-concrete beams", Proceedings of the 20th Australasian Conference on the Mechanics of Structures of Materials, Toowoomba, Australia.
14 Singh, A.V. and Zheng, Y. (2003), "On finite element analysis of beams with random material properties", Probab. Eng. Mech., 18(4), 273-8.   DOI
15 Mirza, O. and Uy, B. (2009), "Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures", J. Constr. Steel Res., 65(3), 662-674.   DOI
16 Mirza, O. and Uy, B. (2010), "Effects of the combination of axial and shear loading on the behaviour of headed stud steel anchors", Eng. Struct., 32(1), 93-105.   DOI
17 Mirza, O., Kaewunruen, S., Donh, C. and Pervanic, E. (2016), "Numerical investigation into thermal load responses of railway transom bridge", Eng. Fail. Anal., 60(2), 280-295.   DOI
18 Standards Australia (2004a), Australian standard AS1170.4 Loading, Sydney, Australia.
19 Standards Australia (2004b), Australian bridge design standard AS5100, Sydney, Australia.