• Title/Summary/Keyword: induced current

Search Result 2,659, Processing Time 0.033 seconds

On the Lightning Induced Voltage Along Overhead Power Distribution Line

  • Izadi, Mahdi;Ab Kadir, Mohd Zainal Abidin;Hajikhani, Maryam
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1694-1703
    • /
    • 2014
  • Lightning induced voltage is a major factor that causes interruptions on distribution lines. In this paper, analytical expressions are proposed to evaluate a lightning induced voltage on power lines directly in the time domain without the need to apply any extra conversions. The proposed expressions can consider the widely used current functions and models in contrast to the earlier analytical expressions which had a number of limitations related to the simplification of the channel base current and the current along the lightning channel. The results show that the simulated values based on the proposed method are in good agreement with the previous studies and the proposed expressions can be used for optimizing the insulation and protection level of existing and new lines being designed.

Modulation of Corydalis tuber on Glycine-induced Ion Current in Acutely Dissociated Rat Periaqueductal Gray Neuron

  • Cheong, Byung-Shik;Nam, Sang-Soo;Choi, Do-Young
    • The Journal of Korean Medicine
    • /
    • v.24 no.4
    • /
    • pp.34-42
    • /
    • 2003
  • This study was designed to investigate the modulation of the Corydalis tuber on glycine-activated ion current in rat periaqueductal gray (PAG) neurons. Aqueous extract from Corydalis tuber has been widely used for pain control such as dysmenorrhea, irregular menstruation or amenorrhea with abdominal cramping, neuralgia, headache and gastrointestinal spasm. The PAG region of the brain is known to be involved heavily with nociception. Modulation of the Corydalis tuber on glycine-induced ion current in rat periaqueductal gray (PAG) neurons was studied by a nystatin-perforated patch-clamp technique. High concentrations of Corydalis tuber elicited ion current, which was suppressed by strychnine application. Low concentrations of Corydalis tuber reduced glycine-induced ion currents in the PAG neurons. Inhibitory action of Corydalis tuber on glycine-activated ion current was reduced by treatment with naltrexone, a non- selective opioid antagonist. Application of N-methylmalemide (NEM), a sulfhydryl alkylating agent, also reduced the inhibitory action of Corydalis tuber on glycine-activated ion current in the PAG neurons. These results suggest that the inhibitory effect of Corydalis tuber on glycine-activated ion current in the PAG neurons is one of the analgesic mechanisms of the Corydalis tuber, which may activate descending pain control system in PAG neurons.

  • PDF

Evaluation of Fluid Forces Acting on Offshore Structures Placed in the Vicinity of Underwater Shoal (수중 천퇴 인근에 설치된 해양구조물에 작용하는 유체력 결정에 대한 고찰)

  • Chun, In-Sik;Min, In-Ki;Sim, Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.2
    • /
    • pp.136-145
    • /
    • 2007
  • When waves propagating over an underwater shoal break at the top of the shoal, wave heights are drastically decreased in the downstream breaking zone, but a secondary current shooting downstream with strong velocity can be induced by the breaking waves themselves. In the case that an offshore structure is placed in the breaking zone, the estimation of wave farce purely based on the visible wave height may cause an under-design of the structure. Thus, for the safe design of the structure, the breaking wave induced current should be necessarily considered in the comprehensive estimation of design load. In the present study, Boussinesq equation model to calculate the wave height distribution and breaking wave induced current was set up and applied to the scheme of a hydraulic model test previously undertaken. Based on the results of the Boussinesq model, fluid forces acting on the model structure were calculated and compared with the experimental results. The importance of the breaking wave induced current was quantitatively assessed by comparing fluid forces with or without current.

Surface current measurements using lagrangian Drifters in Anmok (소형 표류부이를 이용한 안목해안 표층 연안류 관측)

  • Lim, Hak Soo;Kim, Mujong;Shim, Jae-Seol
    • Journal of Coastal Disaster Prevention
    • /
    • v.4 no.spc
    • /
    • pp.245-253
    • /
    • 2017
  • In this study, surface currents measured by small lagrangian GPS drifters (Aquadrifter) in Anmok coastal waters were analysed to account for the variability of nearshore surface current and wave-induced current to understand sediment transport mechanism near the crescentic bars in the surf-zone and near Kangneung breakwater and submerged breakwater in Anmok. The 8 times lagrangian drifter experiments were conducted mostly during in 2nd, 3rd, 4th intensive measurements in winter, summer, and spring seasons with long-term wave observation at the station W1. The analysed surface currents near the breakwaters in Anmok show that wave-induced currents at the middle of the submerged breakwater were separated and flowed toward the shoreline but offshore currents were dominant through the channels between the breakwaters. The longshore currents near the shoreline were flowed to the northwest (southeast) depending on the incoming waves from ENE (NNE). The surface nearshore offshore currents were generated mostly by waves and winds in case of high and low wave energy environments. Using the small-size lagrangian surface drifter experiments, we successfully measured longshore and offshore wave-induced currents in the surf-zone and near submerged breakwater close to Kangneung breakwater. The drifter experiment results show the availability of direct observation of nearshore surface currents to understand the mechanism of sediment transport analysing observed wave-induced current and ebb-current in the surf-zone generated by incoming waves and local winds.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

The Analysis of 4-Conductors Catenary System of AC Railway Feeding System and Calculation of Induced Voltage near Rail Track using the FDTD Method (교류 전기철도 급전계통 4도체군 전차선로 분석 및 FDTD 방법을 이용한 선로 주변 유도전압 계산에 관한 연구)

  • Ryu, Kyu-Sang;Yeom, Hyoung-Sun;Cho, Gyu-Jung;Lee, Hun-Do;Kim, Cheol-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1958-1964
    • /
    • 2016
  • AC railway feeding system use single phase to supply power to the railway vehicles. And the system use the rail track as a return current path, so that current flows in the rail. In this situation inductive interference on communication system and unsafe environment can appear on railway system. Therefore knowing the current distribution of catenary system and analysing the return current is required. In this study detail return current distribution was analyzed by modeling the catenary system as 4-conductors group. The distribution characteristics and trends of return current were studied by using the PSCAD/EMTDC and FDTD method that based on Maxwell equation was used to calculate the induced voltage. Simulation code was made by MATLAB. Using this study result data, we can suggest the proper installation location of digital device and these data can be used for additional studies related to return current or induced voltage as a base data.

Analysis of Wave and Current in Anmok Coastal Waters (안목해안의 파랑과 흐름 분석)

  • Lim, Hak-Soo;Kim, Mujong
    • Journal of Coastal Disaster Prevention
    • /
    • v.4 no.1
    • /
    • pp.7-19
    • /
    • 2017
  • In this study, waves and currents observed by acoustic AWAC, VECTOR and Aquadopp Profiler in Anmok coastal waters were analysed to account for the variability of wave and current and to understand the mechanism of sediment transport generated by wave-induced current in the surf-zone. The monthly variation of wave and residual currents were analysed and processed with long-term observed AWAC data at station W1, located at the water depth of about 18m measured during from February 2015 to September 2016. Wave-induced currents were also analysed with intensive field measurements such as wave, current, suspended sediment, and bathymetry data observed at the surf-zone during in winter and summer. The statistical result of wave data shows that high waves coming from NNE and NE in winter (DEC-FEB) are dominant due to strong winds from NE. But in the other season waves coming from NE and ENE are prevalent due to the seasonal winds from E and SE. The residual currents with southeastern direction parallel to the shoreline are dominant throughout a year except in winter showing in opposite direction. The speed of ebb-dominant southeastern residual currents decreasing from surface to the bottom is strong in summer and fall but weak in winter and spring. By analysing wave-induced current, we found that cross-shore current were generated by swell waves mainly in winter with incoming wave direction about $45^{\circ}$ normal to the shoreline. Depending on the direction of incoming waves, longshore currents in the surf-zone were separated to southeastern and northwestern flows in winter and summer respectively. The variation of observed currents near crescentic bars in the surf-zone shows different direction of longshore and cross-shore currents depending on incoming waves implying to the reason of beach erosion generating the beach cusp and sandbar migration during high waves at Anmok.

Magnetic Field Reduction Characteristics of Hot-Line Worker's Shielding Wear for 765kV Double Circuit Transmission Line (765kV 2회선 송전선 활선 작업자의 차폐복 자계저감 특성검토)

  • Min, Suk-Won;Park, Jun-Hyeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1632-1637
    • /
    • 2007
  • This paper analyses current densities induced inside human body of lineman for 765kV transmission line when he wears a protective cloth or not. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 15[cm], 30[cm], 50[cm], and 100[cm] far from a prefabricated jumper. As results of study, we find a maximum current density induced in all organs may be higher than $10[mA/m^2]$ if he does not wear protective clothes. We also know high permeability materials can lower current density more than high conductivity materials.

Analysis of induced voltage of CCPU with unbalanced current from Distribution Line on Underground Transmission Cable System (지중송전계통에서 배전선 불평형전류 유입에 따른 영향 검토)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Jung, C.K.;Yoon, D.S.;Yoon, J.K.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.459-461
    • /
    • 2005
  • This paper analyses the induced voltage characteristic of CCPU with unbalanced current from distribution line on underground transmission power cable systems. In switching surge strokes, in order to obtain the data of induced voltage/current on CCPU, the actual proof test carried out. This paper is expected to contribute the establishment of proper protection methods of CCPU against the unbalanced current from distribution line on underground transmission power cable systems.

  • PDF

Magnetic field Reduction characteristics of shielding wear for a worker by using AC Arc welder. (교류 아크용접기를 사용하는 작업자의 차폐복 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1343-1344
    • /
    • 2008
  • This paper analyses current densities induced inside a worker using AC arc welder when he wears a protective cloth. Applying the boundary element method, we calculate current densities induced in organs inside a worker in case he was located at 1[cm], 15[cm], 20[cm] far from a power cable of AC arc welder. As results of study, we find a maximum current density induced in all organs may be lower than 10[$mA/cm^2$] if he wears a protective cloth. We also know high permeability materials can lower current density more than high conductivity materials.

  • PDF