Association Between Occupational Physicochemical Exposures and Headache/Eyestrain Symptoms Among Korean Indoor/Outdoor Construction Workers

  • Jung, Sung Won;Lee, June-Hee;Lee, Kyung-Jae;Kim, Hyoung-Ryoul
    • Safety and Health at Work
    • /
    • 제10권4호
    • /
    • pp.437-444
    • /
    • 2019
  • Background: Headache/eyestrain symptoms are common health problems that people experience in daily life. Various studies have examined risk factors contributing to headache/eyestrains, and physicochemical exposure was found to be a leading risk factor in causing such symptoms. The purpose of this study was to examine the relationship of headache/eyestrain symptoms with physicochemical exposure among Korean construction workers depended on worksite. Methods: This study used data from the 4th Korean Workers Conditions Survey and selected 1,945 Korean construction workers as participants. Multivariable logistic regression analysis was used to determine the relationship. Results: Exposure to vibrations among all construction workers affected the moderate exposure group [odds ratio (OR) 1.53, 95% confidence interval (CI) 1.01-2.32], the high exposure group (OR 1.77 95%CI 1.17-2.67), and the indoor high exposure group (OR 1.61, 95%CI 1.02-2.55) and among outdoor construction workers, the moderate group (OR 6.61, 95%CI 15.4-28.48) and the high group (OR 6.61, 95%CI 1.56-27.98). When exposed to mist, dust, and fumes, the indoor high exposure group was significantly affected (OR 1.63, 95%CI 1.07-2.47). All construction workers exposed to organic solvents were affected, high exposure group (OR 1.69, 95%CI 1.15-2.49) and indoor high exposure group (OR 1.77, 95%CI 1.08-2.89). The high exposure group in all construction worker (OR 1.70, 95%CI 1.20-2.42) and the indoor high exposure group (OR 1.83, 95%CI 1.17-2.89) also were affected by secondhand smoking exposure. Conclusion: Many physicochemical exposure factors affect headache/eyestrain symptoms among construction workers, especially indoor construction workers, suggesting a deficiency in occupational hygiene and health environments at indoor construction worksites.

외기 오존 농도에 따른 반도체 작업환경 및 사무실에서의 오존 농도 변화 연구 (A Study of Ozone Variations in a Semiconductor Fabrication Facility and Office Related to the Ozone Concentration in the Outdoor Air)

  • 이지은;정명구;최광민
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.188-197
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.

Study on the Performance of Wireless Local Area Network in a Multistory Environment with 8-PSK TCM

  • Suwattana, Danai;Santiyanon, Jakkapol;Laopetcharat, Thawan;Charoenwattanaporn, Monton;Goenchanart, Ut;Malisuwan, Settapong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.549-551
    • /
    • 2002
  • A Wireless Local Area Network (WLAN) is a flexible data communication system implemented as an extension to, or as an alternative for, a wired LAN with in a building or campus. However, communications in an indoor environment present problems not encountered in outdoor wireless communication systems. Since cellular type systems are interference limited, the indoor environment is more hostile than the outdoor environment due to the lower propagation constant. In this paper, the equation for the signal to interference ratio in a multistory building will be derived. Knowing the S/I ratio, the floor frequency reuse can be determined. Finally, the simulation in this research is designed to study the performance (BER) of WLAN system in the multistory environment by applying the 8-PSK Trellis Coded modulation technique. The procedure allows a quick evaluation of BER in Wireless LAN system due to the co-channel interference.

  • PDF

착상조건에서 R744 냉매 적용 탑차용 냉장시스템의 성능해석 (Performance Simulation of a R744 Refrigeration System in a Refrigerator Truck under a Frost Condition)

  • 김상훈;명치욱;조홍현
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.499-505
    • /
    • 2013
  • R744 has been appropriated for substitute refrigerant, because of its high stability, and environment-friendly nature as a natural refrigerant. To analyze the cooling performance of a refrigeration system in a refrigerator truck using R744 according to the blocking ratio, an analytical model of the refrigeration system was developed under frost conditions, using EES. The performance of the refrigeration system was predicted with the indoor and outdoor air temperature, outdoor air velocity, and compressor speed. As a result, the system performance decreased, with the increase of frost growth. When the blocking ratio was 40.4% in the basic condition, the refrigeration capacity was decreased by 27.1%, compared to the non-frost condition.

실내 공기 중 일부 알데하이드류에 대한 위해도 평가 - 일부 주택 및 아토피 환자 주택을 대상으로 (Risk Assessment of Aldehydes in Some Residential Indoor Air Included Atopy Patient's Homes)

  • 문경환;변상훈;최달웅;이은일;오은하;김영환
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.19-26
    • /
    • 2006
  • This study was undertaken to determine the concentrations of 15 aldehydes in air samples collected from 21 households including 9 atopy patient's homes and to assess the extent of exposure and risk for an individual due to inhalation. Of all the aldehydes identified in both indoor and outdoor environment, formaldehyde and acetaldehyde were the most abundant aldehydes, which were occupied $60\%\;and\;17\%$ of total amount, respectively. The geometric mean concentration of formaldehyde and acetaldehyde in indoor air were $170.5\pm1.9\;{\mu}g/m^3\;and\;47.3\pm1.5\;{\mu}g/m^3$, respectively. There existed a strong correlation between formaldehyde, acetaldehyde and other aldehydes. And the ratio of indoor and outdoor concentrations (I/O) exceeded 1.0 for almost every measured aldehydes except m-tolualdehyde... No associations were found between the level of aldehydes and either housing characteristics or living habits in most of the samples with only a few exception. And the concentrations of all aldehydes indoor air between atopy patient's homes and control homes were not significant(p>0.05). Formaldehyde and acetaldehyde exposures and risks were estimated by using the inhalation unit risk, mean concentrations and the 95th percentiles, and which were $2.6\times10^{-3}\;and\;1.1\times10^{-4}$, respectively. The mean and the 95th percentile risk estimates were 25 times higher for formaldehyde than for acetaldehyde in homes.

신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성 (Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments)

  • 장성기;천재영;이태형;임수길;류정민;서수연;임정연
    • 분석과학
    • /
    • 제20권1호
    • /
    • pp.17-24
    • /
    • 2007
  • 신축공동주택에서 발생되는 실내공기 오염물질 중 휘발성유기화합물 및 카보닐화합물의 농도분포특성을 파악하고자 신축공동주택 120세대를 대상으로 실내공기 오염도 실태조사를 실시한 결과, 입주 전 신축공동주택의 실내공기 오염물질 농도는 톨루엔이 $272.81{\mu}g/m^3$, m, p-자일렌 $98.90{\mu}g/m^3$, 포름알데히드 $71.68{\mu}g/m^3$, 아세톤 $70.58{\mu}g/m^3$, 에틸벤젠 $49.76{\mu}g/m^3$로 조사되었다. TVOCs 물 구성비의 경우, 표준물질로 확인된 물질이 42.5%를 차지하였으며, 이 중 톨루엔이 18.5%로 가장 많은 비중을 차지하였다. 카보닐화합물의 경우, 포름알데히드와 아세톤이 각각 43.1%, 42.4%를 차지하였다. 또한, 주요 실내공기 오염물질의 실내/실외 농도비를 조사한 결과 벤젠은 1.29로 낮은 농도비로 조사되었으며, 톨루엔은 3.59, 포름알데히드는 10.76, o-자일렌은 28.74의 실내/실외 농도비를 나타내었다.

지상과 지하역사의 실내공기질 특성과 외기영향 평가 (Characteristics of indoor air quality in the overground and underground railway stations)

  • 남궁형규;송지한;김수연;김희만;권순박
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.17-25
    • /
    • 2016
  • 본 연구에서는 지하역사와 지상역사에서의 실내공기질을 측정하고, 외부 공기에 의한 영향 정도를 확인하고자 하였다. 측정된 물질은 '실내공기질 관리법'상에서 유지기준과 권고기준으로 지정된 항목 중, 농도가 검출되지 않은 석면을 제외한 미세먼지($PM_{10}$), 이산화탄소($CO_2$), 일산화탄소(CO), 이산화질소($NO_2$), 폼알데하이드(HCHO), 오존($O_3$), 총부유세균(TAB), 총휘발성유기화합물(TVOC), 라돈 등 9종이다. 또한 미세먼지, 이산화질소, 오존 등 세 가지 물질은 I/O ratio를 통해 외기에의한 영향을 확인하였다. 공기질 측정결과 지상역사에 비해 지하역사에서 미세먼지, 폼알데하이드, 총휘발성유기화합물, 이산화질소, 라돈 등이 높은 농도로 검출되었으며, 이는 지하역사 내부에 그 오염물질의 발생요소가 존재하기 때문으로 판단된다. 오존 농도는 지상역사에서 지하역사보다 높은 농도로 검출되었으며, 특히 외부로 노출되어있는 지상역사 승강장에서 높은 농도를 보임으로써 외기 유입에 의한 영향이 있는 것으로 확인되었다. 따라서, 외기에 의한 영향을 받는 오염물질은 역사의 기계환기시 제거 과정을 거쳐 오염물질의 실내유입을 차단하고, 지하역사에서 기인한 미세먼지 등의 물질들은 실내에서 그 발생원에 따른 별도의 처리가 필요할 것으로 판단된다.

A Comprehensive Analysis of the End-to-End Delay for Wireless Multimedia Sensor Networks

  • Abbas, Nasim;Yu, Fengqi
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2456-2467
    • /
    • 2018
  • Wireless multimedia sensor networks (WMSNs) require real-time quality-of-service (QoS) guarantees to be provided by the network. The end-to-end delay is very critical metric for QoS guarantees in WMSNs. In WMSNs, due to the transmission errors incurred over wireless channels, it is difficult to obtain reliable delivery of data in conjunction with low end-to-end delay. In order to improve the end-to-end delay performance, the system has to drop few packets during network congestion. In this article, our proposal is based on optimization of end-to end delay for WMSNs. We optimize end-to-end delay constraint by assuming that each packet is allowed fixed number of retransmissions. To optimize the end-to-end delay, first, we compute the performance measures of the system, such as end-to-end delay and reliability for different network topologies (e.g., linear topology, tree topology) and against different choices of system parameters (e.g., data rate, number of nodes, number of retransmissions). Second, we study the impact of the end-to-end delay and packet delivery ratio on indoor and outdoor environments in WMSNs. All scenarios are simulated with multiple run-times by using network simulator-2 (NS-2) and results are evaluated and discussed.

다중이용시설에서의 실내공기중 미생물 분포에 관한 연구 (Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings)

  • 김윤신;이은규;엽무종;김기영
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

서울시 지하철 2호선의 가을철 객실 PM2.5 농도의 특성 (Characteristics of In-cabin PM2.5 Concentration in Seoul Metro Line Number 2 in Autumn)

  • 신혜린;정현희;이기영
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.186-191
    • /
    • 2019
  • Objectives: Subway is one of the most common transportation modes in Seoul, Korea. The objectives of this study were to determine characteristics of in-cabin $PM_{2.5}$ concentration in Seoul Metro Line Number 2 and to identify factors of the $PM_{2.5}$ concentration. Methods: In-cabin $PM_{2.5}$ concentrations in Seoul Metro Line Number 2 were measured using real-time monitors and the factors affecting $PM_{2.5}$ concentration in cabin were observed. Linear regression analysis of in-cabin $PM_{2.5}$ concentration and indoor/outdoor (I/O) ratio were performed. Results: In-cabin $PM_{2.5}$ concentration was associated with the in-cabin $PM_{2.5}$ concentration in previous station. In-cabin $PM_{2.5}$ concentration was correlated with ambient $PM_{2.5}$ concentration and associated with underground station with control of the in-cabin $PM_{2.5}$ concentration in previous station. I/O ratio increased as the number of passengers increased and when passing through the underground station with control of I/O ratio in previous station. Conclusion: In-cabin $PM_{2.5}$ concentration was affected by ambient $PM_{2.5}$ concentration. Therefore, management of in-cabin $PM_{2.5}$ concentrations should be based on outdoor air quality.