• Title/Summary/Keyword: indoor relative humidity

Search Result 208, Processing Time 0.04 seconds

A Study on the Indoor Environmental Factors of Granite Dome Models with Different Envelop Materials during the Summer Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • During the summer season, it is very hot and humid in Korea. So the humidity is an important factor regarding the environmental control function of building envelops. The purpose of this research is to measure and analyze the characteristics of such environmental factors as relative humidity, dry bulb temperature and air velocity varies both in the clay and cement envelop structures using granite dome models during the summer time. The interior relative humidity of the clay model is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF

Photocatalytic Destruction of Chlorinated and Aromatic Hydrocarbons for Low-Level Indoor Air Cleaning (저농도 실내공기 정화를 위한 염소화 및 방향족 탄화수소의 광촉매 분해)

  • Jo, Wan Geun;Gwon, Gi Dong;Choe, Sang Jun;Song, Dong Ik
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.767-777
    • /
    • 2004
  • This study evaluated the technical feasibility of the application of $TiO_2$ photocatalysis for the removal of volatile hydrocarbons(VHC) at low ppb concentrations commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) of VHC, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VHC. None of the target VHC presented significant dependence on the RH, which are inconsistent with a certain previous study that reported that under conditions of low humidity and a ppm toluene inlet level, there was a drop in the PCO efficiency with decreasing humidity. However, it is noted that the four parameters (HD, RM, FT and IPS) should be considered for better VHC removal efficiencies for the application of $TiO_2$ photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VHC at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO were a negligible addition to the indoor CO levels. These abilities can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Effect of Foliage Plant Pachira aquatica on the Change of Indoor Temperature and Humidity (관엽식물 파키라가 실내 온·습도 변화에 미치는 영향)

  • Son, Ki-Cheol;Kim, Mi-Kyoung;Park, So-Hong;Chang, Myoung-Kap
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.377-380
    • /
    • 1998
  • In order to investigate the effects of foliage plants on the changes of indoor thermal- and hygro- environments, experiments were carried out in two rooms with similar physical factors. Changes of indoor environmental parameters according to the existence of plants, their arrangement methods, and the existence of wrapseal for protecting the loss of water from the pot soil were measured during certain periods in winter and summer season, using Pachira aquatica which is widely used as indoor plant and has higher photosynthetic and traspiration rate than other foliage plants. The data suggested that the existence of plants didn't affect directly on the indoor thermal environment, while relative humidity increased about 3~5%, regardless of season, by putting plants which had volume equivalent to 2.4% of room volume. In summer, there was no difference in increasing effect of relative humidity between parallel arrangement with window and spread arrangement in the room, but in winter the former arrangement was more effective than the later.

  • PDF

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

A Study on Thermal Comfort of Korea Men감s Wear in Summer - Based on Indoor Environment conditions - (하계 남성복의 온열쾌적감에 관한 연구 - 실내 환경조건을 중심으로 -)

  • 정상열;고경태
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.10a
    • /
    • pp.364-368
    • /
    • 1997
  • The purpose of this Study was to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate Variability(HRV), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at 50% R.H., 24C, and the difference of skin temperature was found at the calf area as air temperature changes. At low air temperature and low humidity, heart rate was decreased, but there was no change at brain wave, keeping a-wave.

  • PDF

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • The purposes of this study were to determine the actual state of indoor environments of solitary elderly houses in the rural district during winter and to analyze the relationship between the influencing factors and indoor physical elements. Field surveys consisted of measurements of physical elements, observations of living factors, and resident's responses in interviews. Field surveys were carried out in 4 houses from $28^{th}$ of February to $2^{nd}$ of March 2008. The elements measured were air temperature, relative humidity, floor temperature, seating-place temperature, CO2 concentration, CO concentration, and illumination. The results showed that the average indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was 30.6~55.4%, floor temperature was $13.9{\sim}24.0^{\circ}C$, temperature when seated was $27.6{\sim}51.1^{\circ}C$, $CO_2$ concentration was 1434.6~3305.5 ppm, CO concentration was 2.8~8.4 ppm, and illumination was 31.0~96.7 lux. The residents' clothing values were 1.10~1.78 clo. The environment was evaluated as being in an unsuitable state, and it was revealed that the main reason was the lack of heating and ventilation.

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.452-457
    • /
    • 2008
  • The purposes of this study were to determine the actual state of indoor environment and to analyze the relationship between the living factors and indoor physical elements in solitary elderly houses at rural district during winter. The field surveys were consisted of measurements of physical elements, observations of living factors, and interviews of resident's responses. The field surveys were fulfilled in 4 houses from February to March 2008. Measuring elements were air temperature, relative humidity, floor temperature, seated place temperature, $CO_2$, CO, and illumination. The results showed that the average of indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was $30.6{\sim}55.4%$, floor temperature was $13.9{\sim}24.0^{\circ}C$, seated place temperature was $27.6{\sim}51.1^{\circ}C$, $CO_2$ was $1434.6{\sim}3305.5ppm$, CO was $2.8{\sim}8.4ppm$, illumination was $31.0{\sim}96.7lux$. The residents' clothing values were $1.10{\sim}1.78clo$. Most of the residents' subjective responses were in discord with the physical elements. It was evaluated to be uncomfortable state, and the main reason was revealed lack of heating and ventilation.

  • PDF

The Study on the Thermal Comfort of Rural Housing in Chung-nam area (충남지역 농촌 주거용 건물의 열쾌적성능에 관한 연구)

  • Park, Jae-Sang;Yoo, Jong-Ho;Park, Jae-Wan;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.202-207
    • /
    • 2011
  • This study has measured indoor temperature and relative humidity and evaluated it for one year by selecting Chungnam's rural areas for improving indoor environment of rural housing in the circumstance that the environment of housing is poor due to deterioration of rural housing. As a result of its evaluation, the indoor temperature difference by household appeared to be more than $13^{\circ}C$, and it was measured that the indoor temperature was mostly low. A difference of more than 40% in case of relative humidity occurred, so the difference of the indoor environment by household was clear. In case of the thermal comfort zone, the number of households that are distributed to more than 50% of a thermal comfort criterion in the winter was only 3 households, rather than the summer.

  • PDF

A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room (Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가)

  • Song, Min-Jeong;Shin, Hoon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.

Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space (실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향)

  • Ju, Jin-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.