• 제목/요약/키워드: indoor model test

검색결과 111건 처리시간 0.029초

$2GHz{\sim}10GHz$ 무선 채널 환경에서 비례 적응형 등화기를 이용한 SC-FDE 시스템 구현과 성능분석 (Analysis of Performance for SC-FDE Systems Using Proportional Adaptive Equalizer in $2GHz{\sim}10GHz$ Frequency Radio Channel Models)

  • 양용석;이규대
    • 한국통신학회논문지
    • /
    • 제32권4C호
    • /
    • pp.447-453
    • /
    • 2007
  • 다중 경로 페이딩 환경에서 OFDM(Orthogonal frequency Division Multiplexing)방식은 보호 구간 및 주파수영역 등화로 심벌 및 채널 간 간섭을 방지하는 특성을 가지는 반면 전송신호의 PAPR(Peak-to-Average Power Ratio)크다는 것이다. SC-FDE(Single Carrier with Frequency Domain Equalization)방식은 OFDM과 유사한 성능을 가지면서 상대적으로 PAPR이 적은 반면 등화기가 복잡하다. 본 논문에서는 SC-FDE시스템을 위한 주파수영역 비례 적응형 등화기를 제안하고, $2GHz\;{\sim}\;10GHz$ 대역의 다양한 채널모델 환경 하에서 성능을 분석함으로 802.11 및 802.16 등에 효과적으로 적용할 수 있음을 제시하였다. 아울러 동일조건의 OFDM시스템과 성능을 비교하여 수렴속도가 빠르고 단말기의 복잡도를 줄일 수 있음을 시뮬레이션을 통해 증명하였다.

빙해선박 상부갑판 열선의 열전달 특성에 따른 착빙방지 성능평가 및 설계기준에 관한연구 (A Study on the Anti-Icing Performance Evaluating and Design Guide by Heating Coil for Upper Deck of Icebreaking Vessels)

  • 이종찬;서영교;이춘주
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.541-549
    • /
    • 2012
  • The study adopted a freezing prevention method of the upper deck which used heating coil, and carried out numerical analysis by using ANSYS 13.0 CFD for design guide of the vessel operating in cold region. It is based on the experimental results of the anti-icing performance tests which were carried at cold room chamber in MOERI. Numerical analysis for the design guide was performed by considering S.S.T. (Shear Stress Transport) turbulent model for flow separation effects and the turbulence which occurred in interfaces of the numerical model in order to express appropriate heat transmission phenomenon. The numerical result shows average temperature of the upper deck surface appeared similarly compared with the indoor chamber test. The design guide for optimum freezing prevention presented through heat transmission capability and interval of the heat coil in various outdoor temperature($10^{\circ}C{\sim}-30^{\circ}C$) and wind speed(1m/s~7m/s).

Experimental study on the horizontal bearing characteristics of long-short-pile composite foundation

  • Chen-yu Lv;Yuan-cheng Guo;Yong-hui Li;An-di Hu-yan;Wen-min Yao
    • Geomechanics and Engineering
    • /
    • 제33권4호
    • /
    • pp.341-352
    • /
    • 2023
  • Long-short pile composite foundations bear both vertical and horizontal loads in many engineering applications. This study used indoor model tests to determine the horizontal bearing mechanism of a composite foundation with long and short piles under horizontal loads. A custom experimental device was developed to prevent excessive eccentricity of the vertical loading device caused by the horizontal displacement. ABAQUS software was used to analyze the influence of the load size and cushion thickness on the horizontal bearing mechanism. The results reveal that a large vertical load leads to soil densification and increases the horizontal bearing capacity of the composite foundation. The magnitude of the horizontal displacement of the pile and the horizontal load borne by the pile are related to the piles' positions. Due to different pile lengths, the long piles exhibit long pile effects and experience bending deformation, whereas the short piles rotate around a point (0.2 L from the pile bottom) as the horizontal load increases. Selecting a larger cushion thickness significantly improves the horizontal load sharing capacity of the soil and reduces the horizontal displacement of the pile top.

고속 스캔 MTI 펄스 레이더의 지형 클러터 제거 능력 최적화에 관한 연구 (A Study on Optimizing the Clutter Rejection Capability for a High-Speed Scanning MTI-Pulse Radar)

  • 김종건;장헌순
    • 한국전자파학회논문지
    • /
    • 제20권10호
    • /
    • pp.1077-1083
    • /
    • 2009
  • MTI(Moving Target Indicator) 방식으로 구현된 레이더에 있어서 안테나 고속 회전시 발생되는 지형 특성에 따른 고정 클러터의 도플러 주파수 스펙트럼 확산 현상에 대해 신호 처리 파라메터값(MTI 필터 단수, M/N Detector 비율, CFAR(Constant False-Alarm Ratio)의 K-factor 및 offset값)을 조정하여 지형 클러터의 제거 능력을 최적화하였다. 최적화 구현은 지형 클러터의 유형별 데이터 수집을 위한 치구를 설계 및 활용하여 유형별 지형 클러터 데이터를 수집하였으며, 이의 유형별 분석 및 제거 능력 최적화를 위해 Matlab 시뮬레이션을 통하여 test case를 만들고, 레이더 실내 시험 및 지형별 야외 시험을 통한 반복 검증을 수행하여, 진화적 개발 모델과 같이 반복, 점진적인 과정으로 병행되는 최적화를 수행하였다. 연구 결과, 기존 레이더 시스템에 비해 7.5 dB(5.6배) 이상의 지형 클러터 제거 능력 향상 효과를 거두었다.

국가기본도용 Hybrid 공간정보 모델 개발 (Development of Hybrid Spatial Information Model for National Base Map)

  • 황진상;윤홍식;유재용;조성환;강성찬
    • 한국측량학회지
    • /
    • 제32권4_1호
    • /
    • pp.335-341
    • /
    • 2014
  • 새로운 정보기술 환경에 적합한 국가기본도용 데이터 및 DB 모델을 개발하고자 본 연구에서는 시공간지도구조, 정보연계용 프레임워크지도, 다중레이어 토폴로지구조 등을 주요 특징으로 하는 Hybrid 공간정보 모델을 개발하였다. 공간정보에 "시간"이라는 새로운 차원을 추가하여 공간객체의 시간에 따른 변화가 반영되는 DB 구조를 설계하였고, 다축척 융합지도 구조와 고유 ID 체계를 부여하여 타 정보와 연계 융합하여 활용할 수 있도록 하였다. 또한 기존 2차원 지도의 표현상 한계를 극복하고자 실내 및 지하정보를 포함하는 구조와 지형 지물에 대한 토폴로지 및 복합표현 구조를 설계하였다. 설계결과를 반영한 시범구축을 통해 개발된 모델의 성능을 평가한 결과 다양한 정보들과의 시공간 연계를 통해 활용도가 향상된 국가기본도용 데이터 및 DB 모델의 구현 가능성을 확인할 수 있었다.

아스팔트 콘크리트 궤도용 사전제작형 슬래브 패널 개발 (Development of Prefabricated Slab Panel for Asphalt Concrete Track)

  • 백인혁;이성혁;신응수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권3호
    • /
    • pp.75-82
    • /
    • 2019
  • 아스팔트 콘크리트(AC) 궤도는 열차 하중에 의한 궤도 하부노반의 발생응력을 최소화하고, 적외선에 민감한 AC의 노출면적을 감소시켜 온도 영향에 따른 AC 도상의 소성변형을 줄일 수 있는 슬래브 패널 개발이 매우 중요하다. 본 연구에서는 형상 설계 및 실내성능시험을 통해 AC 궤도용 슬래브 패널을 개발하였으며, KRL-2012 표준열차하중 모델 및 KR-C코드에 의한 다양한 정적 하중조합에 따른 슬래브 패널에 작용하는 휨 인장응력 및 설계모멘트를 유한요소해석을 통해 구조 안전성을 검토하였다. 또한 AC 궤도용 슬래브 패널의 설계 적합성을 검증하기 위하여, EN 13230-2에 의거 슬래브 패널 주요 위치별로 정적 휨 강도 시험, 동적 휨 강도 시험을 수행하였다. 성능 시험 결과, AC 궤도용 슬래브 패널은 균열 하중 및 균열 확대 여부 등 유럽 표준에서 요구되는 성능 기준을 모두 만족하였다.

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

교육시설의 공기환경 실측에 관한 연구 (A Study on the Measurement of Indoor Air Pollutants in High School Building)

  • 김선정;김병수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1392-1397
    • /
    • 2008
  • This study is to measure the change of the $CO_2$ and floating dust concentration depending on the volume of the ventilation and the state of on/off the ventilation for the estimation of the air pollution in classroom. The results could be summarized as follows: the test cell was the two full scaled model and the one is set up with ventilation system another was not. the volume of classroom is 170.1m3 and the number of persons are 35. 1)when the ventilation system was not installed, The experimental results of the $CO_2$ concentration showed the average of 2,150ppm and the maximum of 2,740ppm in the classroom. This was the higher than 1,000ppm, the standard value of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development, 1000ppm. The $CO_2$ concentration was relatively increasing during school hours. 3)In case of the volume of ventilation of $800m^3$/h, the $CO_2$ concentration of classroom showed the average of 962 ppm and the maximum of 1,380 ppm. This was higher than 1,000ppm, the standard of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 4)The floating dust(PM10) was the maximum of 0.52 mg/$m^3$, the minimum of 0.25 mg/$m^3$, and the average of 0.32 mg/$m^3$ in case of the ventilation system off. Those were higher than the standard value 0.15 mg/$m^3$. In case of the ventilation system on, the floating dust(PM10) was the maximum of 0.174 mg/$m^3$ , the minimum of 0.048 mg/$m^3$, and the average of 0.078 mg/$m^3$. These were the lower than 0.15 mg/$m^3$, the standard of the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 5)The concentrations of $CO_2$ and PM10 were largely depending on the number of students and the ventilation system, The installation of the ventilation system is necessary for the amenity environment and the management of the indoor air quality.

  • PDF

모형토조실험에 의한 초연약지반의 표층개량에 관한 연구 (Research on the Surface Improvement of High Soft Ground Using Calibration Chamber Test)

  • 방성택;연용흠
    • 한국지반환경공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.39-46
    • /
    • 2019
  • 준설점토를 활용한 연약지반은 장비주행성 및 진입로의 확보를 위해 시멘트 계 고화재 및 무기질 고화재 등을 활용한 표층고화처리공법이 사용되고 있으나 환경에 유해한 물질의 용출로 인한 문제가 제기되고 있어 환경과 기능성을 모두 만족하는 표층고화처리 공법의 개발이 필요하다. 표층처리 공법으로는 조기강도와 장기적인 안정 등을 고려하여 시멘트계 고화재를 이용한 표층고화처리공법이 많이 활용되고 있으며, 지반개량 효과가 크고 경제적 효율성으로 인해 국 내외에서는 시멘트계 고화재를 이용한 표층개량에 대한 연구과 수행되어 지고 있다. 그러나 최근 환경과 기능성의 문제가 제기되어 시멘트에서 발생되는 6가크롬(Cr6+), 수은(Hg) 등의 유해물질로 인해 지반오염과 환경문제가 발생되어 다양한 친환경적인 공법의 개발이 요구되고 있는 실정이다. 따라서 이 연구에서는 자연함수비의 준설점토를 시멘트와 친토양고화재를 혼합한 혼합토를 대상으로 동일한 배합조건 및 양생조건에 따른 일축압축강도를 분석하고 이 결과를 기준으로 표층개량범위 적용 및 실내모형토조시험을 수행하여 초연약지반의 강도특성 및 지지력 특성을 검토하고자 한다.

젖소 체중추정을 위한 영상처리 알고리즘 (Image Processing Algorithm for Weight Estimation of Dairy Cattle)

  • 서광욱;김현태;이대원;윤용철;최동윤
    • Journal of Biosystems Engineering
    • /
    • 제36권1호
    • /
    • pp.48-57
    • /
    • 2011
  • The computer vision system was designed and constructed to measure the weight of a dairy cattle. Its development involved the functions of image capture, image preprocessing, image algorithm, and control integrated into one program. The experiments were conducted with the model dairy cattle and the real dairy cattle by two ways. First experiment with the model dairy cattle was conducted by using the indoor vision experimental system, which was built to measure the model dairy cattle in the laboratory. Second experiment with real dairy cattle was conducted by using the outdoor vision experimental system, which was built for measuring 229 heads of cows in the cattle facilities. This vision system proved to a reliable system by conducting their performance test with 15 heads of real cow in the cattle facilities. Indirect weight measuring with four methods were conducted by using the image processing system, which was the same system for measuring of body parameters. Error value of transform equation using chest girth was 30%. This error was seen as the cause of accumulated error by manually measurement. So it was not appropriate to estimate cow weight by using the transform equation, which was calculated from pixel values of the chest girth. Measurement of cow weight by multiple regression equation from top and side view images has relatively less error value, 5%. When cow weight was measured indirectly by image surface area from the pixel of top and side view images, maximum error value was 11.7%. When measured cow weight by image volume, maximum error weight was 57 kg. Generally, weight error was within 30 kg but maximum error 10.7%. Volume transform method, out of 4 measuring weight methods, was minimum error weight 21.8 kg.