• Title/Summary/Keyword: indoor evacuation

Search Result 67, Processing Time 0.023 seconds

3D-GIS Network Modeling for Optimal Path Finding in Indoor Spaces (건물 내부공간의 최적경로 탐색을 위한 3차원 GIS 네트워크 모델링)

  • Park, In-Hye;Jun, Chul-Min;Choi, Yoon-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.27-32
    • /
    • 2007
  • 3D based information is demanded increasingly as cities grow three dimensionally and buildings become large and complex. The use of 3D GIS is also getting attention as fundamental data for ubiquitous computing applications such as location-based guidance, path finding and emergency escaping. However, most 3D modeling techniques are focused on the visualization of buildings or terrains and do not have topological structures required in spatial analyses. In this paper, we introduce a method to incorporate topological relationship into 3D models by combining 2D GIS layers and 3D model. We divide indoor spaces of a 3D model into discrete objects and then define the relationship with corresponding features in 2D GIS layers through database records. We also show how to construct hallways network in the 2D-3D integrated building model. Finally, we test different cases of route finding situations inside a building such as normal origin-destination path finding and emergency evacuation.

  • PDF

A Study on Indoor Positioning based on Pedestrian Dead Reckoning Using Inertial Measurement Unit (IMU 센서를 사용한 보행항법 기반 실내 위치 측위 연구)

  • Lee, Jeongpyo;Park, Kyung-Eun;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.521-534
    • /
    • 2021
  • Purpose: In this paper, we propose an indoor positioning scheme based on pedestrian dead reckoning using inertial measurement unit. By minimizing the effects of the orientation error of smart-phone, the more accurate estimation for the direction, the step count, and the stride can be achieved. Method: The effectiveness and the performance of the proposed scheme is evaluated by experiments, and it is compared with the conventional scheme in the same conditions. Result: The results showed that the positioning error of the proposed scheme was 0.76m, while that of the conventional scheme was 1.84m. Conclusion: Sine most people carry his/her own smart-phone, the proposed scheme can be helpful to recognize where he/she was and was heading when the fast evacuation is needed in indoors.

Network Model for Managing Interior Space in Real-Time (실시간 실내 공간관리를 위한 네트워크 모델)

  • Oh, Jung-Woo;Kim, Kyung-Hwan;Lee, Yoon-Sun;Kim, Byeong-Su;Kim, Whoi-Yul;Kim, Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.840-843
    • /
    • 2007
  • There is a tremendous need for an effective indoor facility management since the building are tend to be built taller and bigger due to latest technology, Also, information that is continuously used and transferred during the design and construction phase is emerging due to 3D object-oriented CAD. Therefore, a system that will use such information for facility management should be developed. In this study, we present the methodology for definition the process that generates the Space Network Model automatically and examine the effective value of it.

  • PDF

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

A Comparison of the Trainees' Evacuation Characteristics according to the Indoor Smoke-fullfill during the Safety Training on Ship (선상안전교육 시 선내 연기충진 여부에 따른 실습생의 피난이동특성 비교)

  • Hwang, Kwang-Il;Cho, Ik-Soon;Yun, Gwi-Ho;Kim, Byeol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.422-429
    • /
    • 2018
  • To make students recognize the danger of fire smoke that may occur in ships and to improve the response capability, spaces for safety educ ation were built inside the training ship, and scenarios were developed. This study is an analysis of the movement characteristics of the students acquire d under each scenario. Followings are the summary of the analysis results. In the non-smoke environments, there was no difference in the velocity of escape movement between the case of without block on the familiar route and the case of with unexpected block. However, when the indoor was filled with smoke, the visibility became very low because of the smoke density and the average velocity was 62.5 % slower than the case where it was not. Regardless of the scenarios, the average equivalent velocity on the complex path was faster than the simple straight path, and the standard deviation was smaller. Under the smoke-fullfilled environment, although the relative velocity probability distributions of the complex passage and the entire passag e are very similar, the inter-individual fluctuation of the relative velocity ratio of the complex passage to that of the entire passage was very large. On the other hand, equivalent velocity could be expressed by the logarithmic function of the visibility. Also, as the tension of the students increased, the equivalent velocities were accelerated on all scenarios.

A Study on Tendency of Extended Balcony Unit Plans of LH Corp (LH공사 발코니확장형아파트 단위세대 평면계획경향에 관한 연구)

  • Seo, Boong-Kyo;Choi, Jeong-Oh
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.1
    • /
    • pp.146-153
    • /
    • 2011
  • The purpose of this study was to analyze the type of extended-balcony floor plan which has been reflected as a various forms after making amendment to the apartment extended-balcony legislation on December 2005 and to understand the design tendency of housing unit plan and the characteristic of living space planning by the type of size(pyeong) and extension. The objects of analysis and the plans are 333 example(235 of $84m^2$, 98 of $59m^2$) from the LH corporation competition. The design tendency of balcony space after extension is as follows; First, a type of extension for simple area to increase the area of room adjacent to balcony through balcony extension. Second, a type of functional reinforcement for private room to separate the mixed function followed by strengthening the individual function of the private room. Third, a type of ${\alpha}$-room to play new functions as hobby room, study room, soho-type room with working from home by extending balcony. Fourth, a integrated type to increase flexible efficiency of bed room, living room and kitchen by integrating extended-balcony from the flexible plan. Along with the evaluation of living style through user's environment-behavior research and the counterplan for evacuation space, indoor thermal environment and space for fulfilling the original function of balcony should be proposed in the future study.

Application Plan of Exhaust Systems in Strengthening Evacuation Safety in Apartment Houses (공동주택의 피난안전성 강화를 위한 배기시스템 활용 방안 연구)

  • Lee, Hyun-Sang;Yoon, Myung-Oh;Lee, Young-Ju;Kim, Jeong-Joon
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.49-57
    • /
    • 2020
  • Apartment buildings are becoming taller and more densely populated with the advancements in science and the development of cities, Consequently, various amenities and safety facilities are being developed to improve the quality of life for residents. However, according to statistics, the number of casualties in apartments accounts for a high proportion of accidents, and the leading cause of the casualties is smoke emitted from fires while sleeping at night. Although it is best to install separate indoor facilities in apartments to minimize smoke damages to occupants, it is useful to minimize the smoke damages by utilizing the installed facilities while reducing the financial burden of occupants. Based on the review, the heat exchanger ventilation system and the kitchen collective exhaust system were selected, and the feasibility of these systems was verified through fire simulation. From the verification results, the available safe egress time improved by 27, 30, and 35 s on the 25th, 35th, 50th floors, respectively.