• Title/Summary/Keyword: indoor environmental quality

Search Result 534, Processing Time 0.025 seconds

Comparative Study on Nitrogen Dioxide Exposure of Female Teachers from Kindergarten and House Wives (유치원 여교사(女敎師)와 전업주부(主婦)의 이산화질소 노출비교 및 평가)

  • 양원호;김순복;배현주;이영미;정문호;정문식
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Since most people spend over 80% of their time indoor, indoor air quality tends to be the dominant contributor to personal exposure. In this study, indoor and outdoor $NO_2$concentrations were measured and compared with simultaneously personal exposures of 27 house-wives and female workers of kindergarten. Time activity pattern and house characteristics were used to determine the effects of these factors on personal exposure. Since house-wives student spent most their times in indoor with mean of 89.8%, their $NO_2$ exposure was associated with indoor $NO_2$ level(r= 0.92) rather than outdoor $NO_2$ level(r= 0.87). female workers were also associated with indoor $NO_2$ level(r= 0.70) though sample number were small. Using time-weighted average model, $NO_2$ exposures of house-wives were estimated by $NO_2$ measurements in indoor home and outdoor home levels. Estimated $NO_2$ personal exposures were significantly correlated with measured $NO_2$ personal exposures (r= 0.90). These results might mean that air pollutants exposure of old and feeble persons, and infants could be estimated by measuring concentrations of indoor home.

  • PDF

The Effects of LED Light Quality on Foliage Plants Growths in Interior Environment (실내에서 LED광질이 관엽식물의 생장에 미치는 영향)

  • Kim, Myung-Seon;Chae, Soo-Cheon;Lee, Myung-Won;Park, Gab-Soon;Ann, Seoung-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1499-1508
    • /
    • 2013
  • In the results of investigating the role of LED light quality in enhancing the ornamental value of indoor foliage plants, amber and red light increased plant height, leaf width, and leaf stalk, and the consequent tree shape decreased the ornamental value. The chlorophyll content increased significantly under white light and compound light. With regard to the effect of plant leaf color on ornamental value, the value of lightness was markedly enhanced by red light. As to the functionality of plants according to photosynthetic activity, plants such as Dieffenbachia, Clusia, and Dracaena were found favorable to those staying indoors for a longtime from morning to evening. Spathiphyllum, and Ficus were found to be recommendable for indoor spaces used actively during afternoon because their photosynthesis was activated in the afternoon. With regard to power consumption according to light quality, white light consumed 119 W/hour, around 45% lower than that of fluorescent lamps, so it is considered the optimal artificial light quality that can enhance energy efficiency. Red light consumed 72 W/hour, only 33% of that of fluorescent lamps, but it was not considered the optimal light quality because plant growth was poor under the light quality. White light and compound light were found to be the ideal light sources for improving the functionality and ornamental value of indoor plants and reducing the cost of maintenance, but because compound light hinders people from recognizing the original color of plants and makes their eyes easily tired, white light was considered the optimal light satisfying all of the ornamental value, economic efficiency and functionality resulting from plant growth.

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

Simulation and Health Risk Evaluation of Indoor Air Quality Changes by Ventilation System in New Apartment (신축아파트 환기방식에 따른 실내공기질 변화와 이에 대한 시뮬레이션 및 건강 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.38-45
    • /
    • 2021
  • In this study, air quality conditions were identified and analyzed in real time, at the same time, living habits and ventilation methods were maintained in the daily life of residents, and thus, this present study focuses on the lifestyles of residents. Previous studies showed a difference from this study, focusing on the study on the effects of changes in indoor air quality on human health according to the indoor air quality process test standards of the Ministry of Environment. Formaldehyde concentrations exceeded all ventilation standards, but satisfied the organic standards of the Ministry of Environment when ventilation devices and air purifiers were activated. As such, it was investigated that a large amount of formaldehyde emission in the condo is initially ventilated, but a certain concentration is maintained. The change in PM2.5 concentration according to the ventilation method showed a clear difference. As a result of simulating indoor air flow during natural ventilation, the effects of wind speed and wind direction affect the flow rate of indoor air, and indoor polluted air is stagnant even in the presence of wind and is not completely discharged. When the risk assessment results are averaged on the day of measurement, the trends of change between adults and children are almost equivalent, but the results address that children are more sensitive to risk than adults.

Implementation of Indoor Environment Monitoring and Automatic Control System based on Internet of Things (사물인터넷 기반 실내 환경 모니터링 및 자동제어 시스템 구현)

  • Lee, Sang Hoon;Kim, Jin-Yeop;Kim, Su-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2016
  • Along with the increase in the standard of living, the interest and awareness level of the public about environmental issues have also gradually increased. Recently, time spent on indoor activities have increased and the need for awareness and demand on methods in improving the quality of an indoor environment has been recognized. The purpose of this study is to sense the environment information through real-time monitoring of the room environment by using the IoT based technology and to maintain and improve the indoor environment to an appropriate level through the developed interlocking controller device. This provides an automatic control system in improving the indoor environment at home and other small areas like general offices in place of the traditional passive interior environmental improvement actions or large-scale facility control system. A status analysis with the relative reference values of the air quality and CO2, temperature and humidity and illumination and noise was applied through transmitting a control signal to automatic control module in accordance with the nine indoor environment standards set to improve the indoor environment.

Trend in Study of Biological Pollutants in Indoor Air Quality in Korea (실내공기 중 생물학적 오염물질에 관한 국내 연구 동향)

  • Huh, Eun-Hae;Won, Dong-Hwan;Moon, Kyong-Whan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.4
    • /
    • pp.300-310
    • /
    • 2012
  • Objectives: Indoor air quality problems in public spaces have recently become a very important issue in South Korea, because many spend a long time every day indoors. In this study, an extensive literature review was performed on the subject of suspended bacteria and fungi in public facilities. The objective of this study was to evaluate the extent and types of suspended bacteria and fungi in indoor air in South Korea. This study will provide direction to the research in the field of indoor air. Methods: Article reviews was conducted using a search engine and the following keywords; 'bacteria', 'total suspended bacteria', 'fungi' and 'indoor air' from published articles since 2000. Results: Most of the places of measurement were schools, kindergartens, childcare centers and general hospitals. The highest concentrations of total suspended bacteria and fungi were found in schools and kindergartens. Some public facilities exceeded the standard of 800 CFU/$m^3$. There were few studies on other suspended bacteria: Gram Negative Bacteria, Staphylococcus and Klebsiella pneumoniae. Conclusions: It appears that more studies with intensive controls are needed. It was found that schools and kindergartens were most susceptible to microbial indoor air pollution. These results may be able to suggest an indoor standard for suspended bacteria and fungi in South Korea.

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.