• 제목/요약/키워드: indoor environmental efficiency

검색결과 163건 처리시간 0.024초

都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究 (A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

Design review on indoor environment of museum buildings in hot-humid tropical climate

  • Ogwu, Ikechukwu;Long, Zhilin;Okonkwo, Moses M.;Zhang, Xuhui;Lee, Deuckhang;Zhang, Wei
    • Advances in Computational Design
    • /
    • 제7권4호
    • /
    • pp.321-343
    • /
    • 2022
  • Museum buildings display artefacts for public education and enjoyment, ensuring their long-term safety and the comfort of visitors by following strict indoor environment control protocols using mechanical Heating, Ventilation and Air Conditioning (HVAC) systems to keep the (environmental) variables at a fixed comfort level. Maintaining this requires constant supply of energy currently mostly sourced from the combustion of fossil fuels which exacerbates climate change. However, a review on the effects of the indoor environmental variables on museum artefacts as well as museum visitors revealed that there is no specific point at which artefact deterioration occurs, and that there are wide ranges of conditions that guarantee the long-term safety of artefacts and human comfort. Visits to museum buildings in hot-humid tropical climate of Nigeria revealed that strict indoor environmental practices were adopted. Even when appropriate micro-climatic conditions are provided for artefacts, mechanical HVAC systems remain necessary for visitor comfort because almost no consideration is given to natural ventilation. With the current global push towards energy management, this paper reviewed passive environmental control practices, architectural design strategies, and discusses the adaptation of double skin façade with jali screens, and the notion of smart materials, which can satisfy the range of requirements for the long-term safety of artefacts and levels of human comfort in buildings in hot-humid tropical climate, without mechanical HVAC systems. This review would inspire more discussions on passive, energy efficient, smart and climate responsible popular architecture, challenging current thinking on the impact of the more accepted representative architecture.

Photocatalysis of Low Concentration of Gaseous-Phase Benzene Using Visible-Light Irradiated N-doped and S-doped Titanium Dioxide

  • Jo, Wan-Kuen;Kim, Jong-Tae
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.171-176
    • /
    • 2008
  • Studies on visible-light-driven photocatalysis of air pollutants at indoor air quality (IAQ) levels have been limited. Current study investigated visible-light derived photocatalysis with N-doped and S-doped titanium dioxide ($TiO_2$) for the control of benzene at indoor levels. Two preparation processes were employed for each of the two types of photocatalyst: urea-Degussa P-25 $TiO_2$ and titania-colloid methods for the N-doped $TiO_2$; and titanium isopropoxid- and tetraisopropoxide-thiourea methods for the S-doped $TiO_2$. Furthermore, two coating methods (EDTA- and acetylacetone-dissolving methods) were tested for both the N-doped and S-doped $TiO_2$. The two coating methods exhibited different photocatalytic degradation efficiency for the N-doped photocatalysts, whereas they did not exhibit any difference for the S-doped photocatalysts. In addition, the two doping processes showed different photocatalytic degradation efficiency for both the S-doped and N-doped photocatalysts. For both the N-doped and S-doped $TiO_2$, the photocatalytic oxidation (PCO) efficiency increased as the hydraulic diameter (HD) decreased. The degradation efficiency determined via a PCO system with visible-light induced $TiO_2$ was lower than that with UV-light induced unmodified $TiO_2$, which was obtained from previous studies. Nevertheless, it is noteworthy that for the photocatalytic annular reactor with the HD of 0.5 cm, PCO efficiency increased up to 52% for the N-doped $TiO_2$ and 60% for the S-doped $TiO_2$. Consequently, when combined with the advantage of visible light use over UV light use, it is suggested that with appropriate HD conditions, the visible-light-assisted photocatalytic systems can also become an important tool for improving IAQ.

LEED인증 건축물 분석을 통한 실내공간의 친환경성 개선방안에 관한 연구 (A Study on Eco-friendly Indoor Space of Domestic Eco-certified (LEED)Building through the Cases Analysis & User's Satisfaction)

  • 나민희;한혜련
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.233-240
    • /
    • 2013
  • The building construction sector has been blamed as the main culprit of environmental contamination worldwide. So, there shall be some constructive alternatives in architectural engineering. As one of the alternatives, the LEED ("Leadership in Energy and Environmental Design") has been introduced since 1990s and has been well recognized in saving the resources and energy. "LEED" has also been introduced in Korea since 2002 but it has not put priority on the eco-friendliness of indoor space. In this study, the international and domestic green systems were analyzed and compared in order to restructure the checklist for indoor space. Using the restructured checklists, the questionnaire were sent to 180 people using 6 office buildings which passed the domestic "LEED" certification. LEED certification system put priority on the air quality and heating/cooling environment in its evaluation section and items. However, according to the results of the study, it was found that the people using the buildings were not satisfied enough with the air environment of buildings along with their other indoor environment items. This shows that even though the office buildings are designed according to the requirements of LEED, the buildings do not meet the occupier's needs. In addition, it showed that the evaluation items should be improved so that they are useful to enhance the satisfaction of the occupiers' needs. The paper could be useful in establishing standard for eco friendliness of indoor space of office buildings which pass the LEED certification as the basic data for increasing energy efficiency and working efficiency of occupiers of the buildings.

Predicted Mean Vote(PMV)를 이용한 겨울철 종합병원의 실내 온·열 환경의 평가 (Assessment of Thermal Comfort in a General Hospital in Winter Using Predicted Mean Vote (PMV))

  • 이보람;김정훈;김규상;김혜진;이기영
    • 한국환경보건학회지
    • /
    • 제41권6호
    • /
    • pp.389-396
    • /
    • 2015
  • Objectives: A hospital is a complex building that serves many different purposes. It has a major impact on patient's well-being as well as on the work efficiency of the hospital staff. Thermal comfort is one of the major factors in indoor comfort. The purpose of this study was to determine thermal comfort in various locations in a hospital. Methods: Various indoor environmental conditions in a general hospital were measured in February 2014. The predicted mean vote (PMV) and carbon dioxide ($CO_2$) concentration were measured simultaneously in the lobby, office, restaurant, and ward. Results: The ward was the most thermally comfortable location (PMV=0.44) and the lobby was the most uncomfortable (PMV = -1.39). However, the $CO_2$ concentration was the highest in the ward (896 ppm) and the lowest in the lobby (572 ppm). The average PMV value was the most comfortable in the ward and the lowest in the lobby. In contrast, for concentration of carbon dioxide, the highest average was in the ward and the lowest in the lobby. Due to air conditioner operation, during operating hours the PMV showed values close to 0 compared to the non-operating time. Correlation between PMV and $CO_2$ differed by location. Conclusion: The PMV and concentration of carbon dioxide of the hospital lobby, office, restaurant and ward varied. The relationship between PMV and carbon dioxide differed by location. Consideration of how to apply PMV and carbon dioxide is needed when evaluating indoor comfort.

Purification of BTEX at Indoor Air Levels Using Carbon and Nitrogen Co-Doped Titania under Different Conditions

  • Jo, Wan-Kuen;Kang, Hyun-Jung
    • 한국환경과학회지
    • /
    • 제21권11호
    • /
    • pp.1321-1331
    • /
    • 2012
  • To date, carbon and nitrogen co-doped photocatalysts (CN-$TiO_2$) for environmental application focused mainly on the aqueous phase to investigate the decomposition of water pollutants. Accordingly, the present study explored the photocatalytic performance of CN-$TiO_2$ photocatalysts for the purification of indoor-level gas-phase aromatic species under different operational conditions. The characteristics of prepared photocatalysts were investigated using X-ray diffraction, scanning emission microscope, diffuse reflectance UV-VIS-NIR analysis, and Fourier transform infrared (FTIR) analysis. In most cases, the decomposition efficiency for the target compounds exhibited a decreasing trend as input concentration (IC) increased. Specifically, the average decomposition efficiencies for benzene, toluene, ethyl benzene, and xylene (BTEX) over a 3-h process decreased from 29% to close to zero, 80 to 5%, 95 to 19%, and 99 to 32%, respectively, as the IC increased from 0.1 to 2.0 ppm. The decomposition efficiencies obtained from the CN-$TiO_2$ photocatalytic system were higher than those of the $TiO_2$ system. As relative humidity (RH) increased from 20 to 95%, the decomposition efficiencies for BTEX decreased from 39 to 5%, 97 to 59%, 100 to 87%, and 100 to 92%, respectively. In addition, as the stream flow rates (SFRs) decreased from 3.0 to 1.0 L $min^{-1}$, the average efficiencies for BTEX increased from 0 to 58%, 63 to 100%, 69 to 100%, and 68 to 100%, respectively. Taken together, these findings suggest that three (IC, RH, and SFR) should be considered for better BTEX decomposition efficiencies when applying CN-$TiO_2$ photocatalytic technology to purification of indoor air BTEX.

유엔스튜디오 업무시설 외피 패널의 형태적 특성 분석 (An Analysis of Façade Panel Characteristics of UN Studio's Office Projects)

  • 고성학
    • 대한건축학회논문집:계획계
    • /
    • 제35권8호
    • /
    • pp.23-34
    • /
    • 2019
  • The façade, a fundamental function as a skin that protects human life from external environment such as cold and hot weather, snow, rain, and wind, etc, has served as a media for communication between indoor space of the building and outside space. From the media for communication point of view, the approach to envelope design, in which environmental elements are transmitted internally through the filtering of external environments, has been evolving in various ways from the past to the present. Today, modern architecture technologies including curtain wall systems and user-friendly computer programming and environmental analysis programs demonstrate a differentiated approach to envelope design related to the indoor environment. For this reason, it is worth noting that the envelope design factors and trends that appear variously in the UNStudio's projects before and after the 2000s. The factors reflected in the envelop design in conjunction with the indoor environment obtained through the case study of the UNStudio's office projects were daylight environment, thermal environment, ventilation, noise, privacy and view, and consideration for daylight environment and thermal environment was reflected in many cases through the case study. Looking at the changes in the diagrams in order of year, it can be seen that the envelope design using the environmental analysis tool has been performed since 2006. This is a clue to show the envelop design changes from the conceptual method to the data-based one. The diagrams and analysis results related to the envelop design showed that the thermal environment related to solar radiation was the most, and no diagrams and analysis related to the indoor illumination were found. Since 2010, PV panel installation has been shown in the envelope design, which can be found in the increased efficiency of PV panels due to the technological advances and the decrease in production cost.

Trend Analysis of LEED Certifications: Insights and Future

  • Lee, SeungMin;Kwak, Young Hoon
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1009-1016
    • /
    • 2022
  • As environmental concerns grow, people are becoming more aware of energy efficiency, carbon reduction, and sustainable development. Leadership in Energy and Environmental Design (LEED) certification is currently the most widely recognized building environment assessment method connected to energy and the environment worldwide. This study explores trends for six factors (energy and atmosphere, materials and resources, indoor environmental quality, sustainable sites, water efficiency, and innovation in design) to assess four levels of LEED certification (Platinum, gold, silver, and certified) using 11,209 LEED projects in the United States. The study analyzes trends using scores of percentages of maximum points by certification level, ownership type, space type, and climate zones. With the interest in the Environmental, Social, and Governance (ESG) principle on the rise, this study contributes to a better understanding of the trends and future of LEED certification in the built environment sector.

  • PDF

소형챔버를 이용한 건축자재 오염물질 방출시험방법 평가 (Evaluation of sampling and analytical method for emission experiment of pollutants in building materials using small chamber)

  • 이석조;장성기;김미현;이홍석;임준호;장미;서수연
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.344-354
    • /
    • 2005
  • 최근 들어 실내공기질 악화의 주 오염원인 건축자재에 대한 관심이 고조되면서 건축자재 오염물질 방출시험 자료 구축이 중요하게 됨에 따라, 신뢰성 있는 자료 확보를 위해 건축자재 방출시험 정도 관리에 대한 필요성이 대두되었다. 이에 본 연구는 건축자재 방출시험 성능에 대한 정도관리를 위해 총 휘발성 유기화합물과 포름알데히드에 대하여 기기분석 재현성, 회수율, 검출한계, 중복 및 반복채취 재현성, 파과용량 평가 등을 실시하였다. 기기분석 및 시료채취에 대한 재현성은 20~30% 이내의 양호한 결과를 보였으며, 회수율은 80% 이상으로 나타났으며, 파과 역시 일어나지 않아 소형챔버법에 의한 성능은 전반적으로 만족할 만한 수준을 보였다. 따라서, 소형챔버를 이용한 건축자재 오염물질 방출시험방법은 신뢰성있는 자료를 제공해 줄 수 있을 것으로 판단된다.

Effect of Contaminant Source Location on Indoor Air Quality

  • Lee, Hee-Kwan;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제14권E호
    • /
    • pp.1-7
    • /
    • 1998
  • This paper presents an experimental study for understanding the indoor air quality in a room. A model room, which had a ceiling-mounted supply and a sidewall-mounted exhaust, was used to examine the effect of air exchange rate (AER) and contaminant source location (CSL) as a function of the elapsed time. A tracer gas method, using carbon monoxide tracer, gas analyzers, and a data acquisition system, was applied to study the ventilation air distribution and the tracer removal efficiency, so-called pollutant removal efficiency, in the model room. The experiment was composed of two parts; firstly the AER was varied to examine its effect on the ventilation air distribution and the ventilation effectiveness and secondly both AER and CSL were considered to determine their effect on the pollutant removal efficiency. It was found that the ventilation effectiveness in the model was proportional to AER but not linearly. It was also found that changing the CSL can improve the pollutant removal efficiency. In some cases, the efficiency improvement by increasing AER was achieved by simply changing CSL.

  • PDF