• 제목/요약/키워드: indoor dust

검색결과 239건 처리시간 0.045초

Lung Function of Grain Millers Exposed to Grain Dust and Diesel Exhaust in Two Food Markets in Ibadan Metropolis, Nigeria

  • Iyogun, Kemi;Lateef, Suraju A.;Ana, Godson R.E.E.
    • Safety and Health at Work
    • /
    • 제10권1호
    • /
    • pp.47-53
    • /
    • 2019
  • Background: Despite growing concern over occupational exposure to particulate matter (PM) such as grain dust and diesel exhaust, information about the exposure level and health implications among workers in small-scale milling enterprises in developing countries like Nigeria has not been adequately documented. The purpose of this study was to assess the level of exposure to grain dust and diesel exhaust and effect on lung function among grain millers in food markets in Ibadan metropolis, Nigeria. Methods: The study adopted descriptive cross-sectional design with a comparative approach. Sixteen grain milling shops each were randomly selected from two major food markets in Ibadan metropolis for indoor $PM_{10}$ and $PM_{2.5}$ monitoring. Seventy-two respondents each were proportionately selected from grain millers and shop owners for forced expiratory volume in one second and peak expiratory flow rate tests. Results: The $PM_{2.5}$ concentrations for both market locations ranged between 1,269.3 and $651.7{\mu}g/m^3$, while $PM_{10}$ concentrations were between 1,048.2 and $818.1{\mu}g/m^3$. The recorded concentrations exceeded the World Health Organization guideline limit of $50{\mu}g/m^3$ and $25{\mu}g/m^3$ for $PM_{2.5}$ and $PM_{10}$, respectively. As compared with control group (2.1 L), significantly lower forced expiratory volume in one second value (1.61 L) was observed among the exposed group (p < 0.05). Likewise, significantly lower peak expiratory flow rate value (186.7 L/min) was recorded among the exposed group than the control group (269.51 L/min) (p < 0.05). Conclusion: Exposure to grain dust and diesel exhaust accentuated respiratory disorders with declines in lung functions amongst grain millers. Improved milling practices and engaging cleaner milling facilities should be adopted to minimize exposure and related hazards.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • 유통과학연구
    • /
    • 제17권7호
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

사물인터넷을 활용한 실내 환경 제어 시스템 (Indoor Environment Control System Utilizing The Internet of Things)

  • 안윤정;김동혁;이제현;이붕주
    • 한국전자통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.645-650
    • /
    • 2017
  • 하루 평균 90%를 실내에서 생활하는 현대인들을 위해 온도, 습도, 미세먼지 등을 제어하여 쾌적한 실내 환경으로 제어해 주는 시스템이다. 불쾌지수가 온도와 습도 중 영향이 큰 성분을 찾는 실험에서는 온도를 21도로 고정 했을 시 습도가 1% 변하는 경우 불쾌지수 0.1이 증가하였고 습도를 40%로 고정하고 온도가 1도 변할시 불쾌지수가 1.2씩 변하는 실험결과를 도출하였다. 이로부터 온도가 영향력이 크다는 것을 알아냈다. LED 실내등과 릴레이 소켓을 메인 제어 시스템에 무선통신을 사용하기 위한 블루투스의 통신한계 측정실험에서 장애물이 없을 시 최대 70m 통신 가능 했으며 벽이나 철근과 같은 고분자 장애물이 있는 경우 통과하여 통시할 수 있는 장애물이 최대 2개였고, 고분자 장애물 하나를 사이에 두고 통신 할 수 있는 거리는 최대 10m임을 확인하였다.

유해가스 및 분진이 발생하는 작업장내의 자연환기에 대한 연구 (The Study on Natural Ventilation in Working Places with the Noxious Gas and Dust)

  • 추병길;김철;최종욱;유수열
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.72-79
    • /
    • 2000
  • In recent, occupational diseases in harmful working places become a social issue. It is the well-known fact that a respiration in polluted working places exert a serious effect on health of workers. Accordingly, the cutting off contaminants air originally is the best way to improve working environments. In these cases, ventilation systems should be essentially installed to dilute or exhaust the contaminated indoor air. In this study, we investigated the characteristics of ventilation system of the noxious gas in working indoor places with natural ventilation by using COMET. The numerical simulations were carried out the natural ventilation with two phase(air, dust). For turbulent flow, Reynolds stresses were closed by the standard $\kappa$-$\varepsilon$ model. The results are as follows ; 1) In the natural exhaust in the working place, the flows of the central region have a more rapid velocity vector than the right and left one. 2) Numerical results show that the distribution of contaminants concentration have greater influence on convection than the case of diffusion by government of velocity vectors. 3) To observe the velocity variation with distance, three location of distance are considered. As results, it shows that the velocity are 0.075(m/s) at y=5(m), 10(m) and mean concentration are raised 10.6% at y=5(m), 10(m). 4) We have presented the useful data for the adequate counterplan in the harmful working places by carrying out the various investigation of the natural ventilation.

  • PDF

공기전리 현상과 광촉매를 이용한 공기정화 장치 개발에 관한 연구 (A Study for Development the Air Cleaner Using Air Ionizing Phenomena and Optical Catalizer)

  • 심충한;이원대;이동훈;정용철
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.28-33
    • /
    • 2006
  • The rapidly advanced industrial society takes advantage of high-technology, but it also suffered from the side effects such as various diseases by contamination. Of these problems, air pollution is considered as the most important problem nowadays. Air contamination is not only limited outdoors, but it also causes more serious effect in our indoor air environment. Depending on the notion that indoor air effects physical health seriously, the needs of the air cleaner is more earnest. Therefore, the main purpose of this study is to develop the air cleaner to meet the standard and get rid of poisonous and harmful material from the atmosphere by using a Corona Discharge. According to the purpose of this study, We set the negative ion generator, the UV, $TiO_{2}$ optical catalyzer, the electrical dust collector and the air filter in series order. It emits a lot of negative ions. We use these ions to purify harmful factors and contaminated materials. We collect the dust using static power that comes from the discharge of corona. At the same time, we try to develop the air cleaner to keep the air quality to meet the standard and kill the various viruses using UV LED and $TiO_{2}$ optical catalyzer. In this study, we use the UV LED that is smaller and efficient than a existing UV lamp. What is more, the UV LED has a features that a stabilizer occupying much space is not needed any more.

천식질환이 있는 영유아가 환경요인 중 곰팡이 노출에 따른 영향 (Effect of environmental relationship between fungal exposure and asthma in children)

  • 최길용;김채봉
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2018년도 춘계 종합학술대회 논문집
    • /
    • pp.409-410
    • /
    • 2018
  • Background: Asthma is one of the most common chronic diseases and can be affected by environmental factors. It has been reported that exposure to indoor environmental factors can cause infantile asthma during infancy and childhood, but the previous studies are not yet clear. Climate change has recently been shown to increase indoor mold. Exposure to fungi is known to be directly related to the development of aggravation. Methods: This study was conducted from July 20, 2016 to September 30, 2016. The study was conducted on 90 household with children under the age of 7 who attend atopy school. The questionnaire surveyed allergic symptoms, social and demographic characteristics, and environmental characteristics. Environmentally hazardous substances were measured such as temperature, humidity, fine dust, volatile organic compounds, formaldehyde, bacteria, fungus, house dust mite, endotoxin. Results: According to the survey results, 9 patients (10%) were treated with asthma, 6 (6.7%) were asthmatic patients during the past 12 months, and 4 patients (4.4%) were asthmatic patients during the past 12 months. There were statistically significant differences in the direct effect of smokers in the family (P=0.0328). High-filter vacuum cleaners collected $0.4222CFU/m^3$ in subjects without asthma, and $0.2222CFU/m^3$ in subjects with asthma. In addition, various results confirmed that asthma exacerbated by mold exposure. Conclusions: The results of this study suggest that exposure to fungal by infants and toddlers may play an important role in the development of asthma. In this study, we investigated the relationship between asthma and fungal concentration.

  • PDF

Comparison of Intradermal Skin Test and Multiple Allergen Simultaneous Test Results in Canine Atopic Dermatitis

  • Nam, Hyeyeon;Yun, Taesik;Koo, Yunhoi;Lee, Dohee;Chae, Yeon;Park, Jooyoung;Choi, Dongjoon;Kim, Hakhyun;Yang, Mhan-Pyo;Kang, Byeong-Teck
    • 한국임상수의학회지
    • /
    • 제38권3호
    • /
    • pp.120-126
    • /
    • 2021
  • Intradermal skin test (IDST) is generally considered a useful tool in identifying causal allergens in canine atopic dermatitis. Currently, multiple allergen simultaneous test (MAST), an in vitro testing method for allergen-specific immunoglobulin E, is being used as an alternative method. However, there are no reports comparing the IDST and MAST results in the same dogs. This study compared the results of both tests to evaluate the agreement and correlation between them. The sensitivity, specificity, and accuracy of the MAST were 76.2%, 64%, and 66.7%, respectively. Moderate positive predicted value (PPV, 50-75%) or high sensitivity (80-100%) were identified for indoor allergens, such as cat epithelia, house dust, and house dust mites. In contrast, high negative predicted value (NPV, 93.3-100%) and specificity (60-100%) were observed for environmental allergens and fungi. Although the agreement between IDST and MAST for all allergens was fair (κ = 0.301), that for each allergen was poor (κ < 0.01), except for birch (κ = 0.158). Spearman's rank correlation analysis revealed a low correlation between the MAST and IDST results (ρ = 0.308, p = 0.001). As compared to the IDST results, the MAST results did not identify the causative allergens sufficiently. IDST may not be performed for environmental allergens and fungi with high NPV and specificity if the MAST result is negative, but it may have to be performed for indoor allergens with moderate PPV and high sensitivity when the MAST result is positive.

서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가 (Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station)

  • 임봉빈;이규성;김주인;홍현수;김장원;조경호;정을규;김인규;안연순
    • 한국대기환경학회지
    • /
    • 제30권3호
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

흰개미 가해 목조건축물의 급속 방제를 위한 분말형 약제(Termite Dust) 평가 기준 연구 (Study on the Evaluation Criteria of Termite Dust for Rapid Control of Wooden Structures Damaged by Termites)

  • 임익균;정용재
    • 보존과학회지
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2019
  • 국내에서는 목조건축물의 흰개미 방제를 위하여 여러 방제 방안이 적용되고 있다. 하지만 목부재를 내부를 가해하고 있는 개체에게 빠르게 독성 물질을 접촉시킬 방법이 없어 방제 기간 장기화에 따른 목조건축물의 손상을 지켜볼 수밖에 없는 실정이다. 이에 목부재에 직접적인 천공을 실시하여 내부 개체에게 직접적으로 독성물질을 접촉 전이시켜 빠른 방제 효과를 일으키는 분말형 약제의 국내 도입을 위한 실내 평가 기준 연구를 수행하였다. 먼저 국내 서식 흰개미에 대한 방의 효력의 평가 기준 설정을 위하여 접촉 독성, 전이력 평가를 실시하였다. 접촉 독성 평가 결과 3종의 약제 모두 접촉 후 24시간 이내 100% 사멸이 확인되었으나, 아치사 단계로의 전이 시간에는 차이가 발생하였다. 또한 전이력 평가 결과, 1:9, 1:25 비율 조건에서는 사멸율이 점차 감소하였으나, 약제의 종류에 따라 감소율의 차이가 확인되었다. 이와 더불어 약제 분사 시 목부재 천공의 압축강도 변화 평가를 실시한 결과, 대조군 및 1~3회 천공 조건 간측정값의 차이가 5% 이내로 나타나 목재의 압축 강도에는 큰 영향을 끼치지 않는 것으로 나타났다. 본 연구에서는 분말형 약제의 선정 기준 및 평가 방안과 처리법의 안정성을 평가하여 향후 국내 목조건출물의 흰개미 급속 방제를 위한 해당 방안의 적용 가능성을 확인하고자 하였다.

치과대학병원 종사자의 실내자각증상 관련요인 분석 -서울시내 소재 치과대학병원을 중심으로- (An Analysis about Building-related Health Symptoms of Workers at Dental College Hospitals in Seoul)

  • 조성연;양지연;임영욱;신경희;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • 제24권2호
    • /
    • pp.149-157
    • /
    • 2009
  • In this study, recognized building-related health symptoms of various workers in dental college hospitals are surveyed and analyzed in order to improve indoor environment at dental college hospitals. We conducted a questionnaire survey for 682 workers in three dental college hospitals located in Seoul from Sep. 20 to Oct. 8, 2004. Most workers at dental hospitals complained about noise, poor ventilation, dusty environment, and air dryness. SBS symptoms score for subjects was 1.43${\pm}$0.74 (often feel) and major symptoms was throat, CNS, eye, and nose symptoms. Recognized Building-related health symptoms are significantly related to tasks, working experience, job-satisfaction, indoor environment recognition index, medical history, used to special material, and number of dental unit chair. Also working places and ventilation are significantly related to the symptom. Based on the results, it can be said that special dental treatment causes undesirable environment such as noise, dust, and bad odor. It is also related to recognized building related health symptoms reported by workers at dental hospitals. So managemental efforts are needed to improve indoor environment which is related by dental treatment.