• 제목/요약/키워드: indoor dust

검색결과 236건 처리시간 0.025초

실내 공간별 미세먼지농도 비교 데이터의 시각화 (Visualization of the Comparison between Airborne Dust Concentration Data of Indoor Rooms on a Building Model)

  • 이상익;이진국
    • 한국주거학회논문집
    • /
    • 제26권4호
    • /
    • pp.55-62
    • /
    • 2015
  • The international concern on the inhalable fine dust is continuing to increase. In addition to the toxic properties of the fine dust itself, it can be more dangerous than other environmental factors since the dust pollution is hard to be detected by human sense. Although the information on outdoor air condition can be acquired easily, the indoor dust concentration is another problem because the indoor air condition is influenced by the architectural environment and human activity. It means occupants may be exposed to indoor dust pollution over a long period without being aware. Therefore the indoor dust concentration should be measured separately and visualized as an intuitive information. By visualizing, the indoor dust concentration in each space can be recognized practically in compare with the degree of pollution in adjacent spaces. Besides the visualization outcome can be used as base data for related research such as an analysis of the relation between indoor dust concentration and architectural environment. Meanwhile, with the development of network and micro sensing devices, it became possible to collect wide range of indoor environment data. In this regards, this paper suggests a system for visualization of indoor dust concentration and demonstrates it on an actual space.

비육돈사 공기중 분진 수준에 대한 시계열적 분석 및 돈사내외부 분진 수준 비교분석 (Secular Trend in Indoor Dust Levels with a Comparison of Indoor and Exhaust Outlet Dust Levels in Swine Confinement Buildings)

  • 김형아;김창열;;양수정;;조지훈;;신소정;송은섭;이윤범;김효철;김경란;이경숙;허용
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.630-637
    • /
    • 2019
  • Objectives: This study was performed to evaluate the secular changes in indoor airborne dust or endotoxin levels in the dust from swine confinement buildings. Indoor levels were compared with the level at the exhaust outlet in order to examine the contribution potential of indoor dust to nearby ambient air dust. Methods: Comparisons were made on inhalable and respirable dust levels reported in 2002, 2012, and 2017 from 14, 10, and 36 swine fattening confinement buildings in Korea, respectively. This data was produced by the same research group. Levels of endotoxin adsorbed into inhalable or respirable dust were also compared. Samples of inhalable or respirable dust were collected indoors and at exhaust outlets from 17 swine fattening confinement buildings in 2019, and dust levels were compared between the indoor and the outlet. Results: The outlet inhalable dust level (0.111 mg/㎥) was approximately 19% of that from indoors, and the respirable dust level (0.033 mg/㎥) was approximately 74% of that from indoors. The outlet respirable dust levels were lower than the airborne fine dust levels in the towns where those farms are located. No significant difference was observed in the inhalable dust levels among the years examined, but the respirable dust level in 2017 (0.143 mg/㎥) was significantly lower than in 2002 (0.328 mg/㎥). The level of endotoxin in inhalable dust was significantly higher in 2017 (722 EU/㎥) than in both 2002 (75 EU/㎥) and 2012 (171 EU/㎥). Conclusion: Even though no apparent contribution from swine farm indoor dust to nearby ambient air dust was observed in terms of amount, a certain control strategy to reduce the production of airborne dust and endotoxin from swine farms is merited.

Occurrence of Phthalates in Indoor Dust from Children's Facilities and Apartments in Seoul

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Shin, Dong-Chun
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.382-391
    • /
    • 2009
  • The aim of the study was to assess the levels in typical central borough of phthalate exposure by monitoring children's facilities (19 kindergartens and 21 elementary schools) and households (17 old apartments and 22 new apartments) via sampling indoor floor dust. A vacuum cleaner specifically prepared for sampling dust was attached to a filter of a vacuum cleaner dust collecting container. During the sample preparation process, containers made of glass were used and analysis was performed using GC-MSD. The mean concentration of DEHP was $412{\mu}g/g$, DnBP was $24{\mu}g/g$, and BBzP was $10{\mu}g/g$ dust. The indoor characteristics including floor, wall materials, years after construction, water leakage history for the past three years, and ventilation were also examined to categorize phthalate esters from the dust samples. From the flooring and wallpaper materials of kindergartens and elementary schools, DEHP in the dust sample appeared at a statistically significant level (p<0.05) when PVC materials were present. DEHP in the indoor dust also increased significantly (p<0.01) during the construction period. The daily intake of DEHP measured from indoor dust was 0.08~$19.7{\mu}g/kg/day$ for children and 0.02~$1.1{\mu}g/kg/day$ for adults (women). The results clearly revealed that phthalate exposure is greater in children than in adults (women) due to the indoor dust.

광합성 세균 희석 비율에 따른 시멘트 경화체의 응결 특성 (Setting time properties of cement matrix according to photosynthetic bacterial dilution ratio)

  • 편수정;김대연;임정준;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2018
  • In recent years, harmful substances and fine dust in the air are caused by respiratory and cardiovascular diseases through various mechanisms when they are introduced into the human body through respiration, thereby exacerbating human health and causing cancer by prolonged exposure do. In order to prevent such fine dust from being introduced into the room and to improve indoor air quality, improvement of air quality has attracted attention. Among indoor air pollutants, fine dust and CO2 are pollutants that are directly affected by indoor number and activity. The purpose of this study is to evaluate the basic performance of cement matrix using photosynthetic bacteria as a basic study of fine dust and CO2 adsorption type matrix to suppress indoor air pollution and improve air quality.

  • PDF

일부 주택에서 집먼지 진드기 알러젠 조사 (A Survey of House Dust Mite Allergen Contamination in House)

  • 손종렬;윤승욱;권보연
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.719-723
    • /
    • 2006
  • House dust mite was the most important cause of allergic asthma and rhinitis. More than 70% of Korean children and about 50% of adult with respiratory allergy were sensitive to house dust mite. This experiment was indoor environment in house and house dust mite existence inquiry. From 23rd December 2005 to 28th February 2006, dust samples were collected from the bedclothes by a vacuum cleaner and air sampler And the levels of Der f1 and Der p1 were determined by ELISA((Enzyme-Linked Immunosorbent Assay). The results were as follows : 1 The dust mites allergy contaminations of bedclothes in house were higher than international standards(2000 ng/g). 2. In type of dust mite, the Korean house the almost have the D. farinae other than D. pteronyeeinus of mite. 3. The Der f1 and Der p1 levels per gram of dust from the bedclothes were 2074.99 ng on average, but they did not exist in air. The concentrations of house dust mite were significantly high in the bedclothes. This results suggest that the bedclothes have enough concentrations of dust mites to develop the sensitization. The control of indoor environment should be emphasized to prevent the sensitization by the repeated exposure to dust mite.

주거환경 특성에 따른 집먼지진드기 항원량에 관한 조사 (Effect of a Resident and Indoor Environmental Characteristics on the House Dust Mites Allergen)

  • 김용순;박지원;송영신
    • 지역사회간호학회지
    • /
    • 제13권1호
    • /
    • pp.79-88
    • /
    • 2002
  • Purpose: The purpose of this study was to identify the indoor environment i.e. house type and age, ventilation method, use of bed & sofa, cockroach, ants, etc. on HDM (House dust mites), especially Der fI allergen. Method: Samples of dust from mattresses, pillows and the floor were collected by using a vacuum cleaner from April. 2000. The amount of Group I allergen(Der. fI) of HDM (house dust mites) were measured by two-site ELISA. Indoor Environmental characteristics were accessed by using questionnaires on 178 house wives living in the Seoul area. Results: The amount of HDM allergen (Der fI) was higher in sofa using house. There were higher concentrations of HDM allergen (Der fI) in sofas made from quilt material than for those that were made from leather. Homes that had pets like dogs living in them had higher concentrations of HDM allergen (Der fI) than without dogs. Conclusion: The photophobic mites thrive in dark. warm and humid environments; Items such as pillows. mattresses, box springs, blankets. carpets. and upholstered furniture should be considered ideal environments for the mite. Therefore, an indoor environmental control program should be carried out to avoid the HDM allergen.

  • PDF

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구 (A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color)

  • 이호성;김시국
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.44-52
    • /
    • 2017
  • 본 논문은 분진 색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구이다. 국내 자동화재탐지설비 및 경보설비의 화재안전기준의 개정으로 연기감지기의 실내 적용이 의무화되었으나, 아직까지 국내에서는 실내 환경에서 발생되는 실내먼지 및 환경조건 등에 의해 발생될 수 있는 부작동 및 비화재보에 대한 연구가 미비한 편이다. 이에 본 연구에서는 실내먼지 중 가장 많이 발생될 것으로 판단되는 다양한 색상의 섬유분진에 따른 연기감지기의 실내적응성을 연구하기 위해 국내에 가장 많이 보급화 되어 있는 격자형의 연기챔버를 가진 광전식 연기감지기를 실험대상으로 하고, 갈색, 백색, 회색, 흑색 4종류의 섬유분진을 실험분진으로 하여 분진시험 및 감도시험을 진행하였다. 또한, 연기챔버의 수광부 전압을 측정하여 챔버 내부의 산란현상을 관찰하였다. 실험결과 4종류의 분진 모두 오염도 A에서는 분진시험 및 감도시험에서 모두 적합한 것으로 나타났다. 반면, 오염도 B와 C에서는 갈색, 백색, 회색분진의 경우 작동시험 및 부작동시험에서 분진오염에 의한 오작동이 나타났고, 흑색분진의 경우 작동시험에서 부작동이 발생되는 것으로 확인되었다. 연기챔버의 수광부 전압측정 결과는 갈색 및 백색분진의 경우 오염도가 증가할수록 전압이 증가하였고, 회색 및 흑색분진의 경우 전압이 감소하는 것을 확인하였다.

전주시내 중고등학교 실내.외 환경의 중금속 오염에 대한 연구 (Heavy Metal Contamination of Indoor, Outdoor and Playground in Middle and High School in the Jeonju-City, Korea)

  • 조규성
    • 한국환경과학회지
    • /
    • 제9권6호
    • /
    • pp.495-503
    • /
    • 2000
  • Dust samples were collected from 17 middle and high schools in the Jeonju-city. heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cr, Cu, Ni, Pb and Zn in indoor\`s dusts were highly concentrated. Also heavy metal concentrations in outdoor\`s dusts were similar to that of indoor\`s dusts. Concentrations of Cd, Cu, and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools located at Kangseo-gu and Yangchon-gu , Seoul. Playground dusts in 6 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) greater than 1.0. Most indoor and outdoor dusts exhibited the enhanced heavy metal pollution with a pollution index(by Cullbard et al.) greater than 1.0.

  • PDF

국내 계사(鷄舍) 작업장 유형에 따른 분진 농도 및 발생량 분포 (Distribution of Concentration and Emission of Dust according to Types of Poultry Buildings in Korea)

  • 김기연
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.185-193
    • /
    • 2017
  • Objectives: An on-site study was conducted in order to quantify indoor exposure levels and the emission rate of particulate matter for domestic poultry buildings. Materials and methods: Three types of poultry building (caged layer house, broiler house, and layer house with manure belt) as classified by mode of manure treatment and ventilation were investigated in this study. Nine sites per each poultry building were selected and visited for measuring exposure levels and emission rate of particulate matter. Total dust and respirable dust among the particulate matter were analyzed based on the weight method. Emission rates were estimated by dividing emission amount, which was calculated through multiplying indoor concentration ($mg/m^3$), by the ventilation rate ($m^3/h$), into indoor area ($m^2$) and number of poultry reared in the poultry building. Results: Mean exposure levels for total dust and respirable dust in the poultry buildings were $3.91({\pm}1.99)mg/m^3$ and $1.99({\pm}0.89)mg/m^3$, respectively. The emission rates of particulate matter in the poultry buildings were estimated as $4.75({\pm}1.22)mg\;head^{-1}h^{-1}$ and $64.39({\pm}24.95)g\;m^{-2}h^{-1}$ for total dust and $0.58({\pm}0.23)mg\;head^{-1}h^{-1}$ and $7.52({\pm}2.51)mg\;m^{-2}h^{-1}$ for respirable dust, respectively. The distribution patterns for total dust and respirable dust were similar regardless of poultry building type. Among poultry buildings, broiler house showed the highest exposure level and emission rate of total dust and respirable dust, followed by layer house with manure belt and caged layer house. Conclusions: The finding that the broiler house showed the highest exposure level and emission rate of particulate matter can be attributed to sawdust utilized as bedding material, which can be dispersed into the air by movements of the chickens. Thus, a work environmental management solution for optimally reducing dust concentrations is necessary for broiler houses.