• 제목/요약/키워드: indoor concentration

검색결과 831건 처리시간 0.028초

실내 CO2 농도와 PIR 신호를 활용한 주거건물의 재실 추정 알고리즘에 관한 연구 (A Study on the Algorithm for the Occupancy Inference in Residential Buildings using Indoor CO2 Concentration and PIR Signals)

  • 이규남;정근주
    • 대한건축학회연합논문집
    • /
    • 제20권6호
    • /
    • pp.113-119
    • /
    • 2018
  • Occupancy-based heating control is effective in reducing heating energy by preventing unnecessary heating during unoccupied period. Various technologies on detecting human occupancy have been developed using complicated machine learning algorithm and stochastic methodologies. This study aims at deriving low-cost and simple algorithm of occupancy inference that can be implemented to residential buildings. The core concept of the algorithm is to combine the occupancy probabilities based on indoor CO2 concentration and PIR(passive infrared) signals. The probability was estimated by applying different levels of decrement ratio depending on CO2 concentration change rate and aggregated PIR signals. The developed algorithm was validated by comparing the inference results with the occupancy schedule in a real residential building. The results showed that the inference algorithm can achieve the accuracy of 75~99%, which would be successfully implemented to the control of residential heating systems.

다중이용시설의 위생상태에 관한 조사연구 (A Study on the Sanitation Condition of Public Facility)

  • 김종오;정용택
    • 환경위생공학
    • /
    • 제24권1호
    • /
    • pp.47-55
    • /
    • 2009
  • Indoor air Quality in public facility same as bus terminal and subway station is very important for civil health. The purpose of this study was to investigate the concentration and distribution of PM10 and falling microorganism at the 5 subway stations and bus terminals from Summer 2003 to Summer 2005 in Kyunggi Province. The results were as follows. 1. The highest concentration of PM10 was $187ug/m^3$ at Bucheon Bus Terminal in 2005 while the lowest concentration of PM10 was $78ug/m^3$ at Suwon Bus Terminal in 2003. The year variation of PM10 concentration at the bus terminals in Kyunggi Province was in order of 2005 > 2004 > 2003. The average concentration of PM10 at the five Bus Terminal was $127ug/m^3$. 2. The highest concentration of PM10 was $225ug/m^3$ at Euijungbu Station l in 2004 while the lowest concentration of PM10 was $115ug/m^3$ at Suwon Station in 2003. The year variation of PM10 at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003. The average concentration of PM10 at the five subway stations was $164ug/m^3$. 3. The average amount of falling microoganism at the five bus terminal in Kyunggi Provinc was 201CFU/plate. The minimum is 124 CFU/plate at Seongnam Bus Terminal in 2004 while the maximum is 268CFU/plate at Euijungbu Bus Terminal in summer 2005. The higher concentration of PM10 was 206CFU/plate in 2004 than 199CFU/plate in 2003 and 2005. 4. The minimum is 107CFU/plate at Anyang station in 2003 while the maximum was 263CFU/plate at Euijungbu station in 2003. The average amount of falling microoganism at the five subway stations in Kyunggi Province was 179 CFU/plate. The year variation of falling microorganism at the subway stations in Kyunggi Province was in order of 2004 > 2005 > 2003.

산후조리원 내 신생아실의 실내 환경 특성 - 목재가구류에 따른 실내공기질과 조명배치에 따른 조도 특성을 중심으로 - (Indoor Environment of Infant Units in Postnatal Care Center - Focus on Indoor Air Quality by Types of Wooden Furniture and Intensity of Illumination by Arrangement of Lights -)

  • 정소담;김태욱;장슬애;김석환;이상진
    • 한국가구학회지
    • /
    • 제24권1호
    • /
    • pp.33-41
    • /
    • 2013
  • As professional postnatal care systems have been rapidly supplied, there is sharp increase of postnatal care centers without legal regulations for a mother and a infant. For the quick recovery of mothers, newborn infants that have weaker immune systems are being managed in group in the postnatal care centers. Recently, the attention of the postnatal care centers has been growing because the problem of pneumonia which led to result in a casuality in a infant unit was happen. So, this research analyzed the indoor environment of infant unit through measuring formaldehyde, carbon dioxide, intensity of illumination. As a result of the data, infant units showed higher concentration of formaldehyde and carbon dioxide than Indoor Air Quality Control Law. Moreover, infant units was measured higher intensity of illumination than the range of optimum illumination for infants.

  • PDF

다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구 (Characterization of Airborne Bioaerosol Concentration in Public Facilities)

  • 이철민;김윤신;이태형;박원석;홍승철
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.215-222
    • /
    • 2004
  • This study was conducted to evaluate the characterization of airborne bioaerosol in public facilities in Seoul. A total of 17 public facilities were investigated from December, 2002 to February, 2003. As results of the survey, the mean concentrations of bacteria and fungi in indoor air of public facilities were $378.08\pm296.33$ CFU/㎥ by RCS and $106.38\pm171.63$ CFU/㎥ and $347.46\pm335.32$ CFU/㎥ and $95.23\pm62.61$ CFU/㎥, by Six-stage cascade air sampler respectively. The mean concentrations of bacteria in indoor air (by ventilation method) were $517.14\pm343.93$ CFU/㎥ of natural ventilation and $215,83\pm100.71$ CFU/㎥ of mechanical ventilation. The mean concentrations of fungi in indoor air (by ventilation method) were $83.14\pm79.16$ CFU/㎥ of natural ventilation and $133.50\pm248.07$ CFU/㎥ of mechanical ventilation. The mean concentrations of bacteria in indoor air were 449.44 CFU/㎥ for the ground and $217.50\pm103.68$ CFU/㎥ for the underground. The mean concentrations of fungi in indoor air were $63.89\pm77.66$ CFU/㎥ for the ground and $202.00\pm290.08$ CFU/㎥ for the underground.

Characteristics of Heavy Metal Concentrations and Indoor Atmospheric Environments in Busan Metropolitan Area, Korea

  • Park, Jong-Kil;Kim, Yoo-Kuen;Lee, Hwa-Woon;Jang, Nan-Sim;Park, Moon-Ki
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.801-810
    • /
    • 2002
  • The current paper describes the indoor/outdoor air quality in school environments through analyses of the heavy metal concentrations using Inductive Coupled Plasma(ICP). School environments in a heavy traffic area, two industrial areas, quasi-industrial area, and residential area were evaluated. The results were as follows: (1) The locations with the highest indoor and outdoor concentrations of heavy metals were the industrial areas followed by the heavy traffic area, residential area, and quasi-industrial area in a descending order of magnitude. Plus, the indoor heavy metal concentrations were higher then the outdoor ones. (2) The main heavy metal components were Zn, Al and Ca. Higher concentration levels were found indoors than outdoors. The heavy metal concentrations were also higher in the classrooms than in the corridor or outdoors. (3) The total heavy metal concentrations in the studied areas were highly dependent on the weather elements. including the relative humidity, mixing ratio, and wet-bulb depression. Accordingly, special ventilation systems are recommended to reduce air pollution in school environments.

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

안트라사이트를 혼입한 시멘트 보드의 라돈흡착 특성 (Radon adsorption properties of cement board using anthracite)

  • 경인수;편수정;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2018
  • Among the recent environmental pollution, indoor air pollution has an adverse effect on the health of indoor residents. Radon, one of the causes of indoor air pollution, is released from concrete, gypsum board and asbestos slate among building materials. Radon is a primary carcinogen and is a colorless, tasteless, odorless inert gas that adheres to airborne dust and enters the body through breathing. At this time, there is a risk of developing cancer if the alpha rays from the lononggas entering the human body destroys the lung tissue and is continuously exposed to a high concentration of lonon gas. The World Health Organization (WHO) has emphasized the reduction of radon and its exposure to radon by classifying it as a first-level carcinogen, but many people have not recognized it yet, and the research is underdeveloped. Therefore, this study was carried out to investigate the properties of adsorbed coconut radon to prevent the inflow of radon gas, which is an air pollution source of indoor air, and to prevent inflow into the human body.

  • PDF

차세대 객차용 청정시스템 개발 (Development of Air Cleaning System for Railroad Vehicles)

  • 박덕신;조영민;권순박;박은영;김세영;정미영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2109-2113
    • /
    • 2008
  • As the standard of living is higher, the passengers using public transportations desire better qualities of environment as well as more comfortable indoor environment. In case of train, the passengers' comfort in passenger cabin is one of the most important elements to be competitive with other transport systems. The indoor air quality of the cabin should be managed properly, because many passengers travel for a long time in the small space of $144\;m^3$. For proper management of the air quality, the heating, ventilation and air conditioning (HVAC) system is required for the ventilation of the compartment. To maintain comfortable environment in the compartment, the automatic ventilation system is needed to exchange the indoor air with fresh air or clean indoor air. In this study, we investigated the indoor air quality (PM-10, $CO_2$, and VOCs) in the compartment of train. In addition, type and pattern of PM-10 has been analyzed through the clustering analysis. Based on the analysis, we could found that the fine particulate matters in the compartment can be a serious hazard to human. To control the concentration of PM-10 and $CO_2$ air cleaners were developed. Through this study, it is expected that people who take a train will be in a more comfortable environment.

  • PDF

산업체 작업환경의 실내 공기에서 미생물 오염도 (Microbiologic Pollution of Indoor Air in Industrial Work-Places)

  • 강경희;장명웅
    • 생명과학회지
    • /
    • 제9권3호
    • /
    • pp.314-327
    • /
    • 1999
  • This study was investigated to isolate identify the total bacteria and fungi from the indoor air of work-place of the shoes, paint, stainless steel, and plastic industries. The number of bacterial colonies on the nutrient agar plates were calculated by the open petridish method for 30 minutes in indoor air of work-places at the autumn and winter. The isolated bacteria were identified by Gram stain and biochemical test using API Staph and API 20E kits. The isolated fungal colonies were identified by gross appearance of the giant colonies and microscopic examination of their spore and hyphal characteristics on the slide culture method. The minimum inhibitory concentration (MIC) of several antibiotics against isolated bacteria was determined by the microdilution method with Mueller-Hinton broth. The 70-400 colonies in autumn and 54-236 colonies in winter were isolated from the indoor air of work-places of several industry. The isolation rates of Gram positive cocci, Gram positive bacilli, Gram negative bacilli, and Gram negative cocci were 46.3%, 19.8%, 17.3%, and 16.1%, respectively. In Gram positive cocci, the most strains were identified as Aerococcus spp, Micrococcus spp, and Staphylococcus spp. In Gram positive and negative bacilli, and Gram negative cocci were identified as Bacillus spp, Pseudomonas spp, and Neisseria spp, respectively. The frequently isolated fungi were Aspergillus spp, Penicillium spp and Rhizopus spp, respectively. The frequently isolated Aerococcus spp, Micrococcus spp, and Staphylococus spp were highly resistance against ampicillin, erythromycin, methicillin, and tetracycline. These results arouse our attention to microbiologic pollution in the indoor air of work-places of industries.

  • PDF

신축공동주택에서 플러쉬아웃 실시에 따른 실내 VOCs 농도저감 효과에 관한 연구 (Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment)

  • 박상인;박준석
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.57-63
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out on the reduction of Volatile Organic Compounds(VOCs) concentration in newly built residential buildings. The field measurements were conducted in two complexes of multi-residential buildings which are located suburban areas of Seoul. About three samples of residential buildings were selected in the field measurements. Two samples, B and C, had been flush-out with outdoor air more than seven days. The sample A was maintained at same condition during the flush-out because of the comparison. The indoor concentrations of VOCs in the three samples were measured at three times, before, during, and after flush-out. From the field measurements, it was confirmed that two samples' indoor VOCs' concentrations were considerably decreased after the flush-out comapred with those of the sample A in which the flush-out was not conducted. The decreases of indoor VOCs concentrations were corresponding to about 50% ~ 92% of the concentrations of before. Through the reviews for the previous studies, it was also found that the reduction effects of the flush-out is similar with the those of the bake-out which were reported in the previous studies.