• Title/Summary/Keyword: indoor concentration

검색결과 827건 처리시간 0.037초

일부 주부의 실내공기 중 PAHs 노출에 관한 연구 (An Assessment of Korean Housewives Exposed to Polycyclic Aromatic Hydrocabons(PAHs) in Indoor Air)

  • 이태형;김윤신;손부순
    • 한국환경과학회지
    • /
    • 제16권3호
    • /
    • pp.323-331
    • /
    • 2007
  • Polycyclic aromatic hydrocarbons (PAHs) are well known for strong carcinogen. However, the human exposure analysis of PAHs is quite difficult and unreliable because of hard for estimation of actual expose dose. Then urinary 1-hydroxypyrene (1-OHP) has been a biological marker of exposure to PAHs. The purpose of this study was to investigate total amount from exposure to PAHs soused by indoor occupational exposure, and residence at Seoul metropolitan area and Kyeonggi province in Korea. Thirty-five housewives were included in this study from April 2003 through February 2004. Dietary habit and general characteristics such as age, type of building, existence of passive smoking, period of residence, fuel type for heating and ventilation type were obtained by self administered questionnaire. Urine samples were collected at morning and freeze quickly. Urinary creatinine was measured for converting into 24 hr urine. Concentration of the indoor PAHs was examined by NIOSH method number 5506. Urinary 1-OHP and PAHs were analysed by HPLC. Correlation coefficient between urinary 1-OHP levels and pyrene concentration of indoor air was 0.66 and statistically significant(P<0.01). The difference of urinary 1-OHP level due to dietary habits were not significant. Urinary 1-OHP level of Spring, Summer, Autumn, and Winter were $0.21{\pm}0.12,\;0.10{\pm}0.17,\;0.16{\pm}0.12,\;0.17{\pm}0.14{\mu}g/g$ cr, respectively. The arithmetic means of urinary 1-OHP for four season tee $0.16{\pm}0.14 {\mu}g/g$ cr. There was a trend that urinary 1-OHP level of residents who dwelling in apartment were higher compared with detached home, Comparison of 1-OHP level between heating by kerosene and LPG, Much higher gas heating type than kerosene type (P<0.05). This result implies that the urinary 1-OHP can be applied as the PAHs exposure indices.

Prediction of Indoor Radon Concentration through the Exhalation from Korean Yellow Residual Soil, Hwangtoh as a Building Material

  • LEE, Ju Yong;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권2호
    • /
    • pp.122-133
    • /
    • 2021
  • The radon gas from nature mainly considers a cause of radon problems, and it is closely affect human life cycle. Korean yellow residual soil, Hwangtoh, widely used as a building material, is considered to be one of major sources of indoor radon. However, there have, as yet, been no studies about radon from Hwangtoh in mass market brands. Here, we investigated the indoor radon concentrations and exhalation rates in four Hwangtohs from different brand names and regional features. The Closed Chamber Method (CCM) conducted by a Continuous Radon Monitor (CRM) has been used for the rates of radon exhalation. Based on equations of previous references, the indoor radon concentrations were deducted. As a result, the radon surface exhalation rates resulted in the 1.4208 to 3.0293 Bq·㎡·h-1 range. Significant differences were found among Hwangtohs according to production regions. Materials with higher radon concentration required a longer time to reach a quasi-steady state in a given environment, in other words, the number of half-life cycles increased from a set starting point. The experimentally identified Hwangtohs demonstrated its safety for construction purposes. There exists, so far, a possibility to exert influence radon emanation due to unidentified factors. Therefore, it is necessary to corroborate with more research by increasing the number of Hwangtohs, considering the other references reported high radon exhalation rates. In addition, it is highly recommended that the radon exhalation rates should be measured for all building materials for preventing human health before the material usage.

Effect of Several Native Moss Plants on Particulate Matter, Volatile Organic Compounds and Air Composition

  • Gong, Gyeong Yeop;Kang, Ji Su;Jeong, Kyeong Jin;Jeong, Jun Ho;Yun, Jae Gill
    • 인간식물환경학회지
    • /
    • 제22권1호
    • /
    • pp.31-38
    • /
    • 2019
  • Experiments were carried out to investigate the effects of mosses on the removal of particulate matter (PM 10) and volatile organic compounds (VOCs) in an indoor space and on the composition of air. For particulate matter removal experiments, 0.2 g mosquitto coil was burned in a glass chamber, where three kinds of mosses (Plagiomnium cuspidatum, Myuroclada maximowiczii, Etodon luridus) were placed. For VOCs removal experiments, 1 mL paint thinner was volatilized in a glass chamber, where Plagiomnium cuspidatum and Myuroclada maximowiczii were used. As a result, it was found that particulate matter was effectively removed by the three mosses, and the removal efficiency of particulate matter increased as the amount of mosses increased. The amount of VOCs was similar to the level in the control when a low amount of mosses (2 and 4 plates) was used. However, the removal efficiency of VOCs was significant when 6 plates of mosses were used. On the other hand, formaldehyde concentration was 40 times more than the control and carbon monoxide 30 times, when 0.2 g of mosquito repellent was completely burned in a glass chamber. Also formaldehyde removal effect was significant when 6 plates of mosses were placed. However, there was no change in the concentration of indoor oxygen, temperature and humidity by moss plants. In conclusion, the moss plants were effective in removing particulate matter and VOCs, and they are expected to be used for indoor decoration and landscape in order to improve indoor air quality in the future.

실내녹화 부피비율이 실공간의 미세분진농도, 온도 및 상대습도에 미치는 영향 (Change in the Concentration of Fine Particles, Temperature, and Relative Humidity as Affected by Different Volume Ratios of Interior Greening in Real Indoor Space)

  • 주진희
    • 한국환경복원기술학회지
    • /
    • 제13권2호
    • /
    • pp.1-7
    • /
    • 2010
  • The study objective was to compare the interior greening volume ratios for the change in concentration of fine particle, temperature and relative humidity, and to identify the level of interior landscape volume ratio as a suitable condition to achieve the desired indoor properties. Plants were moved into a room (88m3) randomly. After moving, the volume ratio of the interior greening level was set at 0%, 1%, 2% and 3%. The concentration of fine particles was measured with a mini-volume portable air sampler (Air Metrics, USA). The temperature and relative humidity were recorded with a digital sensor (Kiwi-LTH, USA) during the experiment under different volume ratios with three replications. 1. The results of the change in concentration of the fine particles revealed a trend towards an increased volume ratio of interior greening with decreasing concentration of fine particles, compared to non-plants (0%). The concentration of fine particles at volume ratios of 0%, 1%, 2% and 3% was 55ug/$m^3$, 233ug/$m^3$, 40ug/$m^3$ and 30ug/$m^3$, respectively. 2. The change in temperature, at volume ratios of 0%, 1%, 2% and 3% was $21.2^{\circ}C$, $17.4^{\circ}C$, $16.7^{\circ}C$ and $18.9^{\circ}C$, respectively, in near interior greening, and $22.1^{\circ}C$, $18.7^{\circ}C$, $18.4^{\circ}C$ and $20.5^{\circ}C$ respectively, at a distance of 3m from the interior greening. These study results suggested that temperature was affected by volume ratio and distance from the interior greening. 3. The relative humidity, at volume ratios of 0%, 1%, 2% and 3% was 34.2%, 32.5%, 36.7%, and 46.9%, respectively, in near interior greening, and 31.2%, 26.9%, 31.4% and 38.3%, respectively, at a distance of 3m from the interior greening. With increasing volume ratio of interior landscape, there were positive and significant results between the distance difference and the relative humidity more than temperature.

사무실의 실내 청소 과정에서 부유하는 미세먼지의 크기분포 (Size distributions of suspended fine particles during cleaning in an office)

  • 지준호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.25-33
    • /
    • 2018
  • 본 연구에서는 청소 과정에서 바닥에 먼지가 실내 공기 중으로 비산되는 특성을 공기 중 미세먼지를 측정하여 분석하였다. 신발을 벗지 않고 생활하는 국내 사무실을 대상으로 하였고, 실내 청소 과정에서 발생하는 미세먼지를 측정하였다. 미세먼지($PM_{10}$)와 초미세먼지($PM_{2.5}$)와 $1{\mu}m$ 보다 작은 먼지의 무게농도($PM_{1.0}$)을 분석하였고, 청소 과정에서 발생하는 $0.3{\mu}m$ 이상의 먼지의 크기를 측정하여 분석하였다. 특히, 빗자루질과 진공청소기를 사용하는 과정에서 재비산 되는 미세먼지의 특성을 분석하였고, 입자의 크기에 따른 재비산 특성과 실내 농도 변화 특성을 확인하였다. $PM_{2.5}$$PM_{10}$은 청소 시작과 함께 농도가 증가하였고, 청소 이후에도 실내에 부유하여 장시간 인체에 노출될 수 있을 것으로 보인다. 반면에 $PM_{1.0}$은 상대적으로 청소과정에서 농도가 증가하는 경향을 확인할 수 없었다. 특히, $2.5{\sim}10{\mu}m$ 크기의 먼지는 바닥에 먼지가 많은 조건에서 빗자루질로 청소하는 경우, 초기 농도의 약 60배까지 높아질 수 있음을 확인하였다. 바닥에 먼지가 적은 조건에서 진공청소기를 사용하는 경우도 $2.5{\sim}10{\mu}m$ 크기의 먼지가 증가하였지만 초기 농도의 5배 이하였다. 중성능급 배기필터가 장착된 진공청소기가 가동하는 동안 CPC로 측정된 총 개수농도가 급격히 증가한 후 감소하는 특성이 나타났다. 개수로 대부분을 차지하는 먼지는 250 nm 보다 작은 크기였다. 실내 거주자의 미세먼지 노출은 외부에서 유입된 대기 미세먼지와 실내에서 발생된 실내 생성 미세먼지가 함께 영향을 준다고 알려져 있다. 그렇지만, 국내 실내 활동 중 발생되는 미세먼지에 대한 체계적인 측정과 분석 연구가 많지 않았다. 이미 진행되고 있는 다양한 대기 미세먼지 연구 뿐 아니라 앞으로는 실내의 다양한 활동에 기인한 미세먼지 생성 특성에 대한 심도 깊은 연구가 필요할 것으로 생각된다.

목조문화재에서 계절에 따른 부유 진균의 분포 및 다양성에 관한 연구: 순천 선암사를 중심으로 (Seasonal Distribution and Diversity of Airborne Fungi in a Wooden Cultural Heritage Site: A Case Study of The Seonamsa Temple, Suncheon)

  • 홍진영;김영희;이정민;김수지;조창욱;박지희
    • 한국균학회지
    • /
    • 제46권2호
    • /
    • pp.122-133
    • /
    • 2018
  • 순천 선암사는 산림과 계곡으로 둘러싸여 가파른 지형에 위치하고 있으며 평지보다 온 습도는 높고 바람의 세기가 약하여 생물 피해가 우려되는 곳이다. 이에 계절마다 진균상 조사를 통해 실내 외 공기질에 분포하는 진균의 농도와 다양성을 조사하였다. 외부 공기질에 분포하는 진균의 농도는 봄($276CFU/m^3$)에 가장 높았고, 가을($196CFU/m^3$), 여름($128CFU/m^3$), 겨울($24CFU/m^3$) 순으로 감소하였다. 가장 하단에 위치한 지장전은 여름철에 $337.4CFU/m^3$, 가장 상단에 위치한 원통전은 가을철에는 $333.4CFU/m^3$의 가장 높은 농도를 나타냈다. 실내 외 공기질에서 부유균 농도의 차이가 컸던 계절은 여름철이었으며 $128CFU/m^3$인 외부보다 실내 공기질에 최소 0.5배에서 최대 3배 정도의 많은 진균이 부유하고 있었다. 부유 진균이 가장 많이 수집된 계절은 봄철이었지만 다양성은 여름과 가을철 공기질에서 더 높았는데 여름에는 28속 45종, 가을에는 25속 47종의 진균이 확인되었다. 특히, 가을철에는 모든 조사 지점에서 부유 진균의 분포도가 가장 높았는데 그 중에서 자낭균이 86%를 차지하였고 Cladosporium속이 우점하였다. Penicillim속은16종이 검출되어 종다양성이 가장 높았고 야외보다는 여름과 가을, 겨울철의 실내 공기질에 주로 분포하였다.

작업환경중 톨루엔 농도와 근로자 특성에 따른 뇨중 마뇨산 농도의 상관성 (Correlation of Urinary Hippuric Acid Concentration according to Occupational Exposure Level of Toluene and Worker's Characteristics)

  • 이귀영;신택수;홍상표;김광렬
    • 환경영향평가
    • /
    • 제24권2호
    • /
    • pp.154-162
    • /
    • 2015
  • 작업환경중 톨루엔 농도와 뇨중 마뇨산 농도와의 상관성에 대하여 54개 사업장에서 일하는 124명의 근로자를 대상으로 연구하였다. 가장 높은 실내 작업장의 톨루엔 농도는 인쇄 공정에서 81.116ppm으로 측정되었으며, 기하평균농도는 12.304 ppm으로 높은 값을 나타내었다. 톨루엔 노출 작업자의 뇨중 마뇨산 농도의 기하평균은 0.714 g/g creatinine으로, 비노출군에 비하여 5배 정도 높게 나타났다. 인쇄 공정 노동자의 평균 뇨중 마뇨산 농도는 다른 공정의 노동자에 비해 가장 높은 1.145g/g creatinine 이었다. 작업자의 노출 톨루엔 농도와 뇨중 마뇨산 농도 사이의 상관계수는 r=0.624 (P<0.01)로 상관성이 비교적 높은 것으로 나타났으나, 뇨중 마뇨산 농도와 근로자의 성별, 음주 및 흡연, 근무경력 등의 상관성은 낮게 나타났다. 노출 톨루엔 농도 X에 대한 뇨중 마뇨산 농도 Y의 회귀방정식은 Y = 0.037X + 0.562로 표현할 수 있다. 결론적으로 작업장에서의 톨루엔 노출농도에 따라 뇨중 마뇨산농도가 유의하게 증가함을 알 수 있다.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • 한국환경과학회지
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

전동차 실내공기질 측정 및 $CO_2$ 농도 예측 (A Prediction of $CO_2$ Concentration and Measurement of Indoor Air Quality in the EMU)

  • 소진섭;유성연
    • 한국철도학회논문집
    • /
    • 제11권4호
    • /
    • pp.378-383
    • /
    • 2008
  • 환경부는 2006년 12월에 "대중교통수단 실내공기질 관리 가이드라인"을 제정하였다. 관리항목으로 이산화탄소($CO_2$)와 미세먼지(PM10)에 대해 각각 Level 1(평상시)과 Level 2(혼잡시)로 가이드라인을 제시하였다. 이에 열차와 전동차에 대해 실내공기질 관리가 필요하게 되었다. 본 연구는 2007년 9월과 11월에 4호선(당고개-오이도), 1호선 급행(동인천-용산) 전동차 운행구간을 대상으로 실내공기질을 측정하였다. 또한 전동차 설계검토 사양과 일반적인 공기인자 등의 물성값을 적용하여 $CO_2$ 농도를 예측하였다. 그리고 전동차 실내공기질 실측치와 비교분석 하였다. 측정결과 PM10 농도는 환경부 가이드라인에 각각 44, 57, 45% 수준, $CO_2$농도는 각각 39, 36, 44% 수준으로 양호하였다. 또한 $CO_2$ 농도 예측치와 실측치를 비교한 결과 예측치는 실측치에 유사한 결과로 나타났다.

대전광역시 주택 실내 라돈 농도 분포와 저감 공법 적용 연구 (A Study on the Distribution and Reduction Method of Indoor Radon Concentration in Daejeon Metropolitan City)

  • 장용철;양재환;김홍경;이가인;송하균;김병환;권영선
    • 환경영향평가
    • /
    • 제31권5호
    • /
    • pp.286-295
    • /
    • 2022
  • 본 연구에서는 대전광역시 실내 라돈의 농도 분포를 조사하고 라돈 저감 공법을 적용하여 저감 효율을 평가하였다. 전국주택라돈조사 결과를 기초로 선별된 24개 주택을 대상으로 실내 라돈 측정을 실시한 결과, A자치구의 평균치가 261 Bq/m3로서 기준치를 크게 상회하는 수준임을 알 수 있었고, 동일한 주택에서도 실내 라돈 농도는 측정 지점과 시간에 따라 영향을 받고 있음을 확인하였다. 라돈 저감을 위해 토양 배기법을 적용한 8개 주택의 경우, 실내 라돈 수치는 기준치에 비해 크게 낮아졌으며 평균 저감 효율 역시 55% 정도로 나타나 양호한 라돈 저감 효과를 알 수 있었다. 또한 차폐법을 실시한 2개의 주택에서는 평균 저감 효율이 90% 정도로서 실내 라돈 저감 효과가 매우 우수하였다. 라돈 저감 시 동일한 저감공법을 적용하여도 건물의 구조, 환기의 빈도, 계절 등 여러 요인에 따라 저감 효율이 달라질 수 있으므로 향후 다양한 인자를 반영하여 저감공법의 효과를 정밀하게 평가할 필요가 있다. 이를 기초로 하여 라돈 노출에 의한 인체 위해 저감을 위한 대전광역시 실내 라돈 관리 대책 마련이 필요하다.