• 제목/요약/키워드: indoor cleaning

검색결과 117건 처리시간 0.024초

학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구 (A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom)

  • 박환출;이동현;이정재
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

옥내급수관 세척용 화학세정제 개발 연구 (Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes)

  • 이재훈;정재용;박용배;배재흠;우달식;신현덕
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.162-171
    • /
    • 2010
  • 본 연구에서는 유기산, 무기산, 여러 첨가제들을 이용하여 옥내급수관의 스케일 제거에 적합한 환경친화적인 세정제를 개발하고자 연구를 수행하였다. 여러 유기산 중에서 oxalic acid, citric acid, malic acid 등의 경우 산화철 제거에 비교적 좋은 효율을 보였다. 이들 유기산들을 주축으로 하여 보조제를 첨가하여 옥내급수관 스케일의 주성분인 산화철 제거 평가실험을 하였다. 여러 첨가제 중에 비이온 계면활성제가 산화철 제거력 향상에 매우 뛰어남을 확인할 수 있었다. 그리고 산화철에 대해 높은 용해력을 보인 두 종류의 배합세정제 $F_1$$F_2$를 제조하였는데 배합세정제 $F_1$의 경우 유기산과 첨가제로만 이루어져 있어 기존의 화학세척제에 비하여 안전하고 환경친화적이지만 비교적 산화철 용해력이 조금 떨어졌고, $F_2$의 경우는 $F_1$에 무기산을 소량 첨가함으로 산화철 용해력을 보완해 줌으로써 보다 높은 산화철 세정력을 필요로 할 때 사용하는 것이 좋을 것으로 판단된다. 따라서 옥내급수관 세정 시 스케일의 정도에 따라 배합후보 세정제를 선택하는 것이 바람직하다고 판단된다.

철도차량용 공기청정시스템 개발 (Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

사무실의 실내 청소 과정에서 부유하는 미세먼지의 크기분포 (Size distributions of suspended fine particles during cleaning in an office)

  • 지준호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.25-33
    • /
    • 2018
  • 본 연구에서는 청소 과정에서 바닥에 먼지가 실내 공기 중으로 비산되는 특성을 공기 중 미세먼지를 측정하여 분석하였다. 신발을 벗지 않고 생활하는 국내 사무실을 대상으로 하였고, 실내 청소 과정에서 발생하는 미세먼지를 측정하였다. 미세먼지($PM_{10}$)와 초미세먼지($PM_{2.5}$)와 $1{\mu}m$ 보다 작은 먼지의 무게농도($PM_{1.0}$)을 분석하였고, 청소 과정에서 발생하는 $0.3{\mu}m$ 이상의 먼지의 크기를 측정하여 분석하였다. 특히, 빗자루질과 진공청소기를 사용하는 과정에서 재비산 되는 미세먼지의 특성을 분석하였고, 입자의 크기에 따른 재비산 특성과 실내 농도 변화 특성을 확인하였다. $PM_{2.5}$$PM_{10}$은 청소 시작과 함께 농도가 증가하였고, 청소 이후에도 실내에 부유하여 장시간 인체에 노출될 수 있을 것으로 보인다. 반면에 $PM_{1.0}$은 상대적으로 청소과정에서 농도가 증가하는 경향을 확인할 수 없었다. 특히, $2.5{\sim}10{\mu}m$ 크기의 먼지는 바닥에 먼지가 많은 조건에서 빗자루질로 청소하는 경우, 초기 농도의 약 60배까지 높아질 수 있음을 확인하였다. 바닥에 먼지가 적은 조건에서 진공청소기를 사용하는 경우도 $2.5{\sim}10{\mu}m$ 크기의 먼지가 증가하였지만 초기 농도의 5배 이하였다. 중성능급 배기필터가 장착된 진공청소기가 가동하는 동안 CPC로 측정된 총 개수농도가 급격히 증가한 후 감소하는 특성이 나타났다. 개수로 대부분을 차지하는 먼지는 250 nm 보다 작은 크기였다. 실내 거주자의 미세먼지 노출은 외부에서 유입된 대기 미세먼지와 실내에서 발생된 실내 생성 미세먼지가 함께 영향을 준다고 알려져 있다. 그렇지만, 국내 실내 활동 중 발생되는 미세먼지에 대한 체계적인 측정과 분석 연구가 많지 않았다. 이미 진행되고 있는 다양한 대기 미세먼지 연구 뿐 아니라 앞으로는 실내의 다양한 활동에 기인한 미세먼지 생성 특성에 대한 심도 깊은 연구가 필요할 것으로 생각된다.

객차용 청정시스템 개발 (Development of Amenity-Oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1234-1239
    • /
    • 2006
  • Because the indoors spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF