• Title/Summary/Keyword: indoor and outdoor

Search Result 1,342, Processing Time 0.025 seconds

Modeling Spatial Data in a geo-DBMS using 3D Primitives (Geo-DBMS의 3차원 Primitive를 이용한 공간정보데이터 구축 및 활용 - CityGML을 기반으로 -)

  • Park, In-Hye;Lee, Ji-Yeong
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.3
    • /
    • pp.50-54
    • /
    • 2009
  • Recently, many researches have been conducted to develop 3D Indoor/Outdoor Spatial Data Models. The 3D data created based on these data models have complex data structures. In order to manage these data efficiently, it is better to use a DBMS. There have been many researches to maintain the 3D data in Geo-DBMS, such that Oosterom (2002) and Arens (2005) developed a method to store 3D Building model, geometric and topological data of coverage in DBMSa. In this study, we propose a method to store the CityGML data into the RDBMS, Oracle Spatial 11g.

  • PDF

Measurement and Comparison of Overall Heat Transfer Coefficients for Greenhouse Covering Materials with Thermal Screens (온실용 피복재 및 보온재의 관류열전달계수 측정 및 비교)

  • Diop, Souleymane;Lee, Jong Won;Lee, Hyun Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.4
    • /
    • pp.41-51
    • /
    • 2014
  • 천공복사를 구현할 수 있는 관류열전달계수 측정용 실내실험장치를 제작하고 국내에서 사용되고 있는 온실 피복재 및 보온재의 관류열전달계수를 측정하여 실외실험에서 측정된 결과와 비교하여 타당성을 평가하였다. 외부피복은 0.1 mm 두께의 폴리에틸렌 필름을 사용하여 일중 및 이중피복으로 처리하였다. 이중외부피복조건의 경우 4가지 종류의 보온재를 처리하여 총 6가지 피복처리에 대하여 실험을 실시하였다. 모든 피복처리조건에 대하여 야간복사 유무에 따른 관류열전달계수 측정실험이 수행되었다. 천공복사의 유무에 따라 온실피복재의 관류열전달계수의 변화 경향이 크게 차이가 있었기 때문에 실내실험을 통해 관류열전달계수를 측정하기 위해서는 반드시 실제의 천공복사를 구현할 수 있는 실험장치가 필요할 것으로 판단된다. 실내 실험결과와 실외 실험결과가 비교적 잘 일치하였으며 실내실험장치를 이용하여 관류열전달계수를 측정하는 것이 타당성이 있음을 확인할 수 있었다. 천공복사 유무에 따른 관류열전달계수의 차이는 핫박스 내외부의 온도차이가 증가함에 따라 감소하는 것으로 나타났다.

Schematic Study for 'Korea Style' Exterior Space Planning of Apartment (한국스타일 아파트 단지 외부공간 계획의 기초연구)

  • Choi, Jae-Pil;Kang, Hyo-Jeong;Choi, Young-Jun;Lee, Jung-Won;Hwang, Gyu-Hong
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.109-117
    • /
    • 2010
  • With the IMF crisis in the late 1990's, coupled with the excessive supply of housing stock from the past, construction companies are adopting various differentiating strategies to address the decreasing apartment sales rates. Most of those strategies tend to follow the recent trend of 'eco-friendliness,' creating images of the apartments as 'well-being housing types.' In doing so, green spaces and water features are actively being used in outdoor landscapes design. One specific trend that can be witnessed is the efforts to make reference to the traditional Korean design languages, known as the 'Korean Style.' However, the applications of the 'Korea Style' on landscape design are being explored only by the construction companies, while most researches on the 'Korean Style' focus on its application on the indoor housing units. In this context, this series of case studies of the application of 'Korea Style' on landscape design attempts to extract design elements that can be set as basic guidelines.

A Study on Combination of GPS and RFID in Continuous Indoor/Outdoor Positioning (실/내외 연속 위치결정을 위한 GPS와 RFID 신호의 결합에 관한 연구)

  • Chang, An-Jin;Yang, Sung-Chul;Joo, Hyun-Seung;Yu, Ki-Yun;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.277-282
    • /
    • 2007
  • 유비쿼터스 시대가 도래함에 따라 실외에서 뿐만 아니라 실내에서 대상물의 위치를 결정하기 위한 기술의 필요성이 증가하고 있다. 실외에서는 GPS를 이용하여 광범위한 지역에 안정적인 서비스를 제공받을 수 있지만 건물 인근 지역에서는 위치결정에 필요한 수의 위성이 확보되지 않고, 다중경로 오차의 영향 등으로 위치결정이 불가능하고 실내에서 활용 가능한 수준의 위치 정보를 제공하는 것이 어렵다는 단점이 있다. 실내 위치 결정을 위한 다양한 방법 중에 RFID를 이용한 방법은 GPS 에 비해 위치 정확도는 낮지만 실내에서 비교적 적은 비용으로 위치 결정이 가능하므로 GPS로 위치 결정이 불가능한 지역에 시스템을 구축하면 설내/외에서 연속적인 위치결정이 가능하게 된다. 연속적 위치 결정을 위해 GPS 신호 수신이 가능한 실외 지역에서 RFID 시스템을 설치한 건물 안으로 이동하면서 수신된 데이터를 이용하여 실내외에서의 연속적인 위치결정을 수행하였다. 특히,데이터 에포크 간의 거리를 통해 이상점을 탐지하고, 이상점(Outlier)이 발생할 경우 다른 센서로 위치결정을 대체하는 기법을 제안하였고 그 결과 실내외에서 연속적인 위치결정이 가능함을 확인할 수 있었다.

  • PDF

Implementation of Smart Windows Customized for Indoor and Outdoor Environments (실내외 환경 맞춤 스마트 윈도우의 구현)

  • Kim, Tae-Sun;Park, Byung-Jun;Park, Jun-Hong;Jung, Won-Hee;Shin, Hyo-Bin;Eum, In-Seob;Lee, Do-Gun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.435-436
    • /
    • 2022
  • 창문은 건물의 필수 구조물이지만 창문을 통해서 미세먼지, 빗물 등이 들어올 수 있어 창문을 열고 나가지 못하고 불안해하는 경우가 많다. 최근 들어 미세먼지가 급증하면서 사람들의 불안감이 더욱 증가하고 있으며, 보안에 취약한 창문들이 범죄에 취약하기 때문에 불안해 할 수 있다. 또한, 실내에서도 가스누출 등으로 인해 인명피해까지 이어지는 심각한 상황을 초래할 수 있기 때문이다. 이러한 사람들의 불안감을 없애기 위하여 아두이노를 이용하여 실외의 미세먼지와 빗물, 인체감지등을 통해 원격으로 창문을 제어하고 실내의 온도와 습도량, 가스량의 표시를 어플리케이션을 통해 확인할 수 있으며 원격으로 제어 또한 가능하도록 '실내외 환경맞춤 스마트 윈도우'를 개발하게 되었다.

  • PDF

A Study on Greenspace Planning Strategies for Thermal Comfort and Energy Savings (열쾌적성과 에너지절약을 위한 녹지계획 전략 연구)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.3
    • /
    • pp.23-32
    • /
    • 2010
  • The purpose of this study is to quantify human energy budgets for different structures of outdoor spatial surfaces affecting thermal comfort, to analyze the impacts of tree shading on building energy savings, and to suggest desirable strategies of urban greenspace planning concerned. Concrete paving and grass spaces without tree shading and compacted-sand spaces with tree shading were selected to reflect archetypal compositional types for outdoor spatial materials. The study then estimated human energy budgets in static activity for the 3 space types. Major determinants of energy budgets were the presence of shading and also the albedo and temperature of base surfaces. The energy budgets for concrete paving and grass spaces without tree shading were $284\;W/m^2$ and $226\;W/m^2$, respectively, and these space types were considerably poor in thermal comfort. Therefore, it is desirable to construct outdoor resting spaces with evapotranspirational shade trees and natural materials for the base plane. Building energy savings from tree shading for the case of Daegu in the southern region were quantified using computer modeling programs and compared with a previous study for Chuncheon in the middle region. Shade trees planted to the west of a building were most effective for annual savings of heating and cooling energy. Plantings of shade trees in the south should be avoided, because they increased heating energy use with cooling energy savings low in both climate regions. A large shade tree in the west and east saved cooling energy by 1~2% across building types and regions. Based on previous studies and these results, some strategies including indicators for urban greenspace planning were suggested to improve thermal comfort of outdoor spaces and to save energy use in indoor spaces. These included thermal comfort in construction materials for outdoor spaces, building energy savings through shading, evapotranspiration and windspeed mitigation by greenspaces, and greenspace areas and volume for air-temperature reductions. In addition, this study explored the application of the strategies to greenspace-related regulations to ensure their effectiveness.

An Analysis of Thermal Comforts for Pedestrians by WBGT Measurement on the Urban Street Greens (도심 가로 녹음의 습구흑구온도(WBGT) 측정을 통한 보행자 열쾌적성 효과 분석)

  • Ahn, Tong-Mahn;Lee, Jae-Won;Kim, Bo-Ram;Yoon, Ho-Seon;Son, Seung-Woo;Choi, Yoo;Lee, Na-Rae;Lee, Ji-Young;Kim, Hae-Ryung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • This study aims to measure the thermal comfort effects of urban street trees. As the usual dry bulb air temperature does not indicate properly how the average pedestrian feels the heat of a typical summer day under the strong sunshine, we adopted the Wet Bulb Globe Temperature(WBGT). WBGT involves black globe temperature to measure the direct radiation of sun beams on our bodies, for example our heads. We measured temperatures on very sunny and hot summer days, August 3, 4, and 7, 2012, on the urban streets of Seoul, Korea. Wet bulb, globe, and dry bulb temperatures were measured under direct sunlight from 1 O'clock to 5 O'clock pm. Globe and dry bulb temperatures were measured under street tree shades nearby during the same hours. Then the WBGTs were calculated with the formulae, one for sunny outdoor spaces, and the other for shaded outdoor spaces or indoor. The results are compared with the Korean Standards Association(KS A ISO 7243). The major findings were: 1) On very sunny and hot summer days in Seoul, street tree shades lower the WBGT about 1 to 4 degrees, 2) during the hours of 3 and 4 O'clock in the afternoon, the WBGT under the tree shades are about 3 to 4 degrees lower compared to those under sunshines(approx. 29 to 32 degrees respectively), 3) This difference makes a major thermal comfort for urban pedestrians because senior citizens or weak persons are recommended to move indoor, and even healthy people are recommended stop outdoor sports and take rests in the shades when WBGT is about 32. On the other hand, if the WBGT is around 29, or 3 degrees lower, slower walking, light works or sports are allowable, 4) On site questionnaire survey confirms the thermal comforts under the tree shades, and we even could not get survey subjects on the sunny parts of the sidewalks, 5) We strongly recommend change of guidelines for urban street trees from "one row of street trees on 6m~8m intervals" to "street trees to make continuous shades".

Monitoring the Change of Physical Properties of Traditional Dancheong Pigments (전통 단청안료 표면의 물리적 특성 변화 모니터링)

  • Kim, Ji Sun;Jeong, Hye Young;Byun, Doo-Jin;Yoo, Min Jae;Kim, Myoung Nam;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.549-561
    • /
    • 2020
  • This study aimed to assess the performance and life of nine natural mineral dancheong pigments: Seokganju, Jinsa, Hwangto, Jahwang, Wunghwang, Seokrok, Noerok, Seokcheong, and Baekto. The design of the accelerated weathering test considered the domestic climate characteristics and the location of Dancheong. Outdoor weathering tests were conducted at the Research Institute in Daejeon and the Sungnyemun Gate in Seoul to confirm the field reproducibility of the accelerated weathering test. Monitoring of the physical changes in pigments through accelerated and outdoor weathering tests are based on ultraviolet exposure dose. Despite small cracks at the beginning of the tests, the monitoring showed that Seokganju and Baekto had no marked physical changes, but the surface cracks of Jinsa and Seorok continue to expand. Hwangto and Noerok were marked with water or were resin stained, and the particles of Jahwang, Wunghwang, and Seokcheong had lost their luster. Despite the absolute difference in color change in each test, the final chromaticity change patterns of pigments were similar in that the color difference between Baekto and Noerok was below five, and Jina was above 28. The physical and surface color pigment changes were more concentrated in outdoor weathering tests than in accelerated tests, and the Seoul site was more intense than the Daejeon site. This is because outdoor weathering tests are exposed to severe variations of temperature and moisture or deposition of dust particles and, in the case of Seoul, the site is more exposed to the external environment than the Daejeon site.

Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains (보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.100-105
    • /
    • 2015
  • The calculation method of infiltration loss in greenhouse has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the infiltration rates using the tracer gas method in plastic greenhouses equipped with various thermal curtains. And then the calculation methods of infiltration loss in greenhouses were reviewed. Infiltration rates of the multi-span and single-span greenhouses were measured in the range of $0.042{\sim}0.245h^{-1}$ and $0.056{\sim}0.336h^{-1}$ respectively, single-span greenhouses appeared to be slightly larger. Infiltration rate of the greenhouse has been shown to significantly decrease depending on the number of thermal curtain layers without separation of single-span and multi-span. As the temperature differences between indoor and outdoor increase, the infiltration rates tended to increase. In the range of low wind speed during the experiments, changes of infiltration rate according to the outdoor wind speed could not find a consistent trend. Infiltration rates for the greenhouse heating design need to present the values at the appropriate temperature difference between indoor and outdoor. The change in the infiltration rate according to the wind speed does not need to be considered because the maximum heating load is calculated at a low wind speed range. However the correction factors to increase slightly the maximum heating load including the overall heat transfer coefficient should be applied at the strong wind regions. After reviewing the calculation method of infiltration loss, a method of using the infiltration heat transfer coefficient and the greenhouse covering area was found to have a problem, a method of using the infiltration rate and the greenhouse volume was determined to be reasonable.

Intensive Culture of the Pacific White Shrimp Litopenaeus vannamei, under Limited Water Exchange - II. Indoor Post-Nursery Culture of Juvenile Shrimp - (사육수 비교환 방식에 의한 흰다리새우의 고밀도 사육 - II. 흰다리새우의 실내 중간양성 -)

  • Jang, In-Kwon;Kim, Jong-Sheek;Seo, Hyung-Chul;Cho, Kook-Jin
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Shrimp farming which is entirely conducted in outdoor ponds in the west coast of Korea has been suffered from mass mortality due to viral epizootics. Intensive indoor shrimp culture under limited water exchange can solve these problems of outdoor ponds including viral transmission from environment, pollution due to discharge of rearing water, low productivity and limited culture period. In this study, juvenile L. vannamei (B.W. 0.08-0.09 g) was stocked with $3,000-5,455/m^3$ in density in four raceway tanks (two $12.9\;m^2$, two $18\;m^2$ tanks) and cultured for 42 days with 2.7-3.4% of daily water exchange. Results from four tanks showed FCR of 0.79-1.29, survival of 38.2-48.0%, and yields of $2.49-4.22\;kg/m^3$ which is consistent with 12-20 and 8-14 times higher than those of commercial shrimp hatchery and outdoor pond in Korea, respectively. Concentrations of total ammonia nitrogen in all four tanks were 1.11-1.42 ppm in mean level and did not exceed 6.0 ppm (0.096 ppm of $NH_3$) which is still acceptable levels for shrimp growth. During the culture trial, concentration of $NO_2$-N rapidly increased from stocking, resulting in mean concentration of 18.45-22.07 ppm. It also exceeded 10 ppm over four weeks and maintained at 35-45 ppm for four days in all tanks, accounting for low survival of shrimp due to long-term exposure to high concentration of $NO_2$-N. Nevertheless, the results with survival rate over 38% from raceways which experienced the extreme $NO_2$-N levels suggests that under "biofloc system" white shrimp can acclimate to high $NO_2$-N concentration to some degree.