• 제목/요약/키워드: indoor air quality

검색결과 1,019건 처리시간 0.031초

학교 건물의 실내공기환경 실태조사 연구 (A Field Survey of Indoor Air Environment of Schools)

  • 정민희;정선미;김미연;김건우;박진철
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.865-873
    • /
    • 2007
  • Recently there has been more apprehensions about health and environment. Since the concern has been increased, it is realized that students need to study in comfort and clean environment, and plan to study in environmental friendly facilities. Hence it is needed for both indoor air quality performance evaluation and greening facilities in order to plan environmental friendly schools. Accordingly, this study analyzes the indoor air quality throughout field survey of schools to provide preliminary data to develop environmental friendly education facilities. This paper investigates and analyzes indoor environment standards and performances in schools. There will be included 15 existing schools and 5 newly built schools for survey in Seoul and Gyeonggi. Additionally, environmental problems are also investigated and analyzed by occupants' questionnaires through surveys.

대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도 (Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

주거건축의 IAQ에 관한 연구 (A Study on Evaluation of IAQ in Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.108-112
    • /
    • 1997
  • Recently, the use of Dwelling House has been expanded due to the rapid urbainzation and congestion of population in City. Indoor Air Quality in apartment houses was investigated by measuring pollutants such as $CO_2$ gas, dust concentration. In this study, the mesurements of indoor air environment were performed in Dwelling house in Seoul area to investigate indoor air environment and the relation of air contaminative and the response level. Indoor air contamination and living environment of the occupants have been compared & analyzed with practical investigation of IAQ in Seoul, Korea and Tokyo, Japan.

  • PDF

롤필터를 장착한 객차용공기청정장치 개발 (The development of Air-cleaner with Roll Filter inside railroad passenger car)

  • 이영섭;남궁석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

현장실험을 통한 공동주택의 실내공기환경 평가 (A Evaluation Study on Indoor Air Quality of the Apartment House through Field Measurement)

  • 박용승;배상환;유복희;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.83-87
    • /
    • 2003
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. Various architectural materials are applied and air-tightness of the building is more strengthening to save energy consumption. This is why the air quality of the newly built houses became worse. In this study, contaminants(CO, CO$_2$, Radon, TVOCs, HCHO) density was measured in a newly built house and evaluation was carried out by ASHRAE and EPA Standards. As a result, CO, CO$_2$, TSP and Radon density of the newly built house was in a range of ASHRAE and EPA Standards, but it turned out TVOCs and HCHO density exceeds almost 3${\sim}$5 times in comparison with that of ASHRAE and EPA Standards.

  • PDF

신축건물 사무실내 식물 적용의 실내 공기질 및 재실자 건강영향 평가 - 알레르기 비결막염 및 스트레스 관련 증상설문을 중심으로 - (Impact of Indoor Plants on Indoor Air Quality and Occupational Health in Newly Built Public Building Offices - Focusing on Allergic Conjunctivitis and Stress-related Symptom Questionnaires -)

  • 이용원;임영욱;김광진;김호현
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.334-348
    • /
    • 2017
  • Objectives: We investigated the impacts of indoor plants on indoor air quality and occupational health, focusing on allergic rhinconjunctivitis and stress among employees in new office buildings. Methods: A total of 34 employees working at new public office buildings were enrolled as subjects (n=17, with indoor plants) and as a control (n=17) group. Before and after introducing indoor plants for three months, indoor air quality measurements including VOCs and aldehydes and questionnaires on sick building syndrome, AR symptoms (ARIA based), stress (DASS 42, KOSS, and SACL), and indoor characteristics were performed and statistically analysed. Results: Among the 34 enrolled subjects, 19 were included in the probable AR subject group (subjects with indoor plants, n=8, control n=11) and completed all questionnaires. Statistical analyses were done for total, AR subject groups, and controls. As a result, it was confirmed that major indoor air pollutants decreased after the introduction of indoor plants (p<0.5). Among major symptoms of allergic rhinoconjunctivitis, watery rhinorrhea, nasal stuffiness, and nasal itching indexes decreased (p<0.5, respectively). A decrease was noted in some areas of work-related stress indexes (mainly KOSS) among the subject group (total and AR) and a decrease of indoor environmental attractiveness among the control group (total and AR) (p<0.5, for all). Conclusions: Indoor plants may help reduce indoor air pollutants and decrease AR symptoms and work-related stress of employees in newly built office buildings. Various further follow-up studies on the mechanism of environmental, physical, and emotional influences and utilization of indoor plants in association with allergic diseases will be needed.

바닥재로부터 방출되는 휘발성유기화합물과 폼알데하이드 특성 (Characteristics of VOCs and Formaldehyde Emitted from Floorings)

  • 박현주;장성기;서수연;임준호
    • 한국대기환경학회지
    • /
    • 제25권1호
    • /
    • pp.38-45
    • /
    • 2009
  • Since the seventies and the oil crisis, energy-saving measures have led to a reduction in the ventilation of room. The use of synthetic materials which emit various chemical substances had led to an increase in the concentration of indoor pollutants. "Sick building syndrome (SBS)" and "Sick house syndrome (SHS)" are worldwide problems. Also, the number of complaints about indoor air pollution caused by VOCs (Volatile organic compound) and HCHO (Formaldehyde) has increased. It is important that evaluating and understanding emission of indoor air pollutant from building materials. The object of this study was to evaluate emission test method for flooring such as wood based flooring, carpet tile, rubber tile, PVC sheet and tile, and to determine emission of TVOC and form-aldehyde. The quantity of TVOC and carbonyl compounds emission were sampled and measured by Tenax TA and gas chromatography/mass spectrometry (GC/MSD), 2,4-DNPH cartrige with ozone scrubber and high performance liquid from flooring. The TVOC concentration emitted from carpet tile was ($7.419\;mg/m^2 h$) the highest among 5 groups of test materials. In wood based flooring and PVC tile, the emitted concentration of toluene was high. And the dodecane emission was highest in carpet. The concentration of TVOC decreased by an increase in emission test period. After 7 days, the concentration of TVOC from floorings were about 50% below of the concentration at the first day. TVOC emission from wood based flooring, carpet tile, rubber tile, PVC sheet and tile were decreased in 28 days and remained steady after about 15 days. The concentration of formaldehyde emission from floorings showed extremely low.

거주기간 증가에 따른 신축 공동주택의 실내오염도 변화추이 (Tendency of the indoor pollutants along with increased dwelling period at new apartments)

  • 장성기;류정민;서수연;임정연;이우석
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.453-459
    • /
    • 2007
  • 신축공동주택의 실내공기질에 영향을 미치는 휘발성유기화합물 및 카보닐화합물의 농도와 입주 후 거주기간에 따른 오염도 변화추이를 파악하고자 입주 후 신축 공동주택 120세대를 대상으로 실내공기 오염도를 조사하였다. 신축 공동주택 입주 후 TVOC (Total Volatile Organic Compounds; TVOCs)평균농도는 $688.61{\mu}g/m^3$으로 나타났으며, 포름알데히드, 톨루엔, m, p-자일렌, 아세톤, 에틸벤젠이 $158.56{\mu}g/m^3$, $146.58{\mu}g/m^3$, $69.28{\mu}g/m^3$, $63.80{\mu}g/m^3$, $29.65{\mu}g/m^3$의 순으로 높게 나타났다. 또한, 대부분의 실내오염물질들은 입주 후 거주기간이 증가함에 따라 평균농도가 감소하는 경향을 나타내었으나, d-리모넨의 경우 입주 후 2개월에서 10개월까지 지속적으로 증가하는 것으로 나타났다. 또한, 톨루엔, 에틸벤젠, m, p, o-자일렌 등의 주요오염물질이 전체 VOCs에서 차지하는 비율은 38.8%로 나타났으며, 거주기간에 증가함에 따라 구성비율이 감소하는 것으로 나타났다.

분산주성분 분석을 이용한 고등학교교실 내 오염패턴분류에 관한 연구 (Classification of Pollution Patterns in High School Classrooms using Disjoint Principal Component Analysis)

  • 장철순;이태정;김동술
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.808-820
    • /
    • 2006
  • In regard to indoor air quality patterns, the government introduced various polices that were about managing and monitoring quality of indoor air as a major assignment, and also executed 'Indoor Air Quality Management Act' which was presented in the May, 2004. However, among the multi-usage facilities controlled by the Act, the school was not included yet. This study goal was to investigate PM 10 pollution patterns of the high school classrooms using a pattern recognition method based on cluster analysis and disjoint principal component analysis, and further to survey levels of inorganic elements in May, June, and September, 2004. A hierarchical clustering method was examined to obtain possible objects in pseudo homogeneous sample classes by transformation raw data and by applying various distance. Following the analysis, the disjoint principal component analysis was used to define homogeneous sample class after deleting outliers. Then three homogeneous Patterns were obtained as follows: the first class had been separated and objects in the class were considered to be sampled under semi-open condition. This class had high concentration of Ca, Fe, Mg, K, Al, and Na which are related with a soil and a chalk compounds. The second class was obtained in which objects were sampled while working air-conditioners and was identified low concentration of PM 10 and elements. Objects in the last class were assigned during rainy day. A chalk, soil element and various types of anthropogenic sources including combustions and industrial influenced the third class. This methodology was thought to be helpful enough to classify indoor air quality patterns and indoor environmental categories when controlling an indoor air quality.