• 제목/요약/키워드: indoor air quality(IAQ)

검색결과 186건 처리시간 0.021초

대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응 (The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory)

  • 최윤정;오예슬;장윤정;김정재
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

입주전 신축공동주택의 봄철 TVOC, HCHO농도 실태조사에 관한 연구 (A study on the field measurement of the TVOC and HCHO concentration in the newly constructed apartment houses in spring seasons)

  • 최승혁;김건우;이종식;박진철;김신도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.126-131
    • /
    • 2007
  • This study aims to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as HCHO and VOCs and the field measurement were conducted. According to the field measurement of 60 new houses in spring season, the concentration of HCHO in about 20% were higher the IAQ standards.

  • PDF

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제8권1호
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.

가구 및 목창호재에서 방출되는 유해화학물질의 특성 (The Characteristics of VOCs and Formaldehyde emitted from the furnitures and frame material of windows and doors)

  • 박용승;유복희;조현;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2004년도 추계학술대회 논문집
    • /
    • pp.315-318
    • /
    • 2004
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. The purpose of this study was to estimate on effect of indoor air pollution from VOCs and formaldehyde emitted by building materials. As the results, we knew that concentration of Toluene, Xylene, Styrene and HCHO emitted from the furnitures and frame material of windows and doors are high emission factors on indoor air pollution.

  • PDF

식물을 이용한 실내공기환경 정화효과에 관한 연구 (The Effect of Phytofiltration System on the Improvement of Indoor Air Quality)

  • 송정은;방승기;김용식;손장열
    • KIEAE Journal
    • /
    • 제5권4호
    • /
    • pp.3-8
    • /
    • 2005
  • The objective of this study is to examine the impact of the Phytofiltration system on the improvement of indoor air quality. Measurement was performed in a full-scale mock up model to examine the purification efficiency of air by plants. Seven species of plants, which were recommended by NASA, were used in measurements. Two species of plants that showed outstanding purifying effects were chosen for further measurements. The measurements were performed according to the positions and amounts of plants. Thermal environment, the concentration of Toluene and Formaldehyde were monitored. Ficus Benjamiana and Aglaonema brevispathum were excellent in diluting the concentration of contaminants. The effect of diluting concentration became better as the amount of plants increased. The reducing effect was the best when the plants were placed near window.

건축 마감재와 가구재의 VOCs, HCHO 유해물질에 따른 공동주택 적정 환기량 산정에 관한 연구 (A Study on the Calculation of Ventilation Rate in Apartment House according to VOCs and HCHO Substances of Building Material and Furniture)

  • 최정민;박진석;손영환;박창섭;박민용;이경희
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.101-108
    • /
    • 2005
  • Because of the airtightness of building, misuse of building materials and abuse of furniture, indoor air pollution problems have been increasingly concerned especially with apartment buildings. To improve the IAQ(Indoor Air Quality) in apartment building, this study was aimed at analyzing the factor of interior building material and furniture and calculating the ventilation rate of living room and bed room according to the surface area of interior building material and furniture in terms of VOCs(Volatile Organic Compounds) and HCHO(Formaldehyde). The results of this study are as follows; 1) In the concerned rooms, the living room has less pollution emission rate L(surface area/volume) than that of the bed room but, the living room needs more ventilation rate than that of the bed room because of built-in furniture in terms of VOCs and HCHO. 2) Built-in interior furniture is very important factor in IAQ problems of apartment building, but until now there is no provision about the built-in furniture, so that the provision must be regulated to control the IAQ. 3) To control the IAQ problem, the effective ventilation plans must be established according to the required ventilation rate by means of natural or mechanical ventilation method.

바닥온도와 실내 환기에 따른 인체반응 및 실내공기질 분석 (An Analysis of Human Reaction & IAQ Analysis by Changing the Floor Temperature & Ventilation)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.97-102
    • /
    • 2015
  • Recently many buildings are airtight, deterioration takes the high stage. As this room ventilation is increasingly difficult, the importance of indoor air was emphasized. And Got a few provisions on the indoor ventilation, the building is used for other purposes also requires a lot of careful research. In this study, consisting of floor heating ventilation in the room and wants to know the impact on the human body react with the carbon dioxide concentration in the indoor air were investigated PMV. We have get the data through the experimental study like this. It can be inferred correlations of ventilation and temperature according to human comfort that you should consider when using the work of residential buildings in accordance with the changing social conditions and social. It is also determined that in the future through additional experiments related data can be established basic experimental data.

정전기적 힘을 이용한 실내공기 미세부유먼지 제거 요소기술의 개발을 위한 기술별 시장현황 및 연구 동향 분석 (Analyses of the current market trend and research status of indoor air quality control to develop an electrostatic force-based dust control technique)

  • 윤영한;주진철;안호상;남숙현
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6610-6617
    • /
    • 2013
  • 본 연구에서는 실내공기 오염물질의 제어를 통하여 공기질을 개선 할 수 있는 요소기술의 개발을 위하여 최근의 관련 기술 및 시장 현황을 살펴보고, 실내공기질 오염물질의 특성과 최근에 이루어진 연구를 바탕으로 실내공기질 제어 기술의 특징 및 장 단점을 분석하였다. 적용기술에 따른 공기청정장치의 종류 중에는 현재 필터를 이용한 기계식 여과기술 및 장치산업이 대부분을 차지하고 있으나, 최근에는 설치와 작동이 간편하고 에너지 효율과 기술의 적용성도 좋은 전기전자식 기술이 주목받고 있으며 기계식 장치(5.5%), 이온화 장치(-0.3%), 오존청정(-0.5%) 등 다른 기술에 비하여 향후 시장 발전가능성(성장률 6.3%)이 높은 것으로 분석되었다. 실내 공기질의 오염은 가스상의 VOCs와 입자상의 미세먼지들이 주 원인물질인데 특히 입자가 매우 작은 미세먼지들은 그 특성으로 인체 내부에 깊숙이 침투하여 건강을 위협하고 가스상 오염물질과 반응하여 2차 오염물질을 낼 수 있어 근본적인 제어 기술이 필요하다. 전기전자식 기술 중 유전영동 및 정전기력을 이용한 먼지 제어 기술은 전기적으로 미세먼지와 같은 입자를 부유시켜 제어하는 기술로서 미세부유먼지에 많은 사람들이 노출될 수 있는 다중이용시설 등에 적용될 수 있으며 이를 위해 실내 온도 및 습도, 대상물질의 수분 함량과 같은 주변 조건에 의한 부유먼지의 이동 특성이 함께 고려되어야 한다. 미세 부유먼지를 효과적으로 제어할 수 있는 전기전자식 기술을 이용하여 다중이용시설 뿐 아니라 사무실 및 일반가정 등의 실내 공기질 개선을 위한 핵심기술로 발전할 수 있는 가능성이 높을 것으로 판단된다.

도시철도 객실 공기질 평가모델 개발 (Development of Air Quality Assessment Model for Subway Cabin)

  • 권순박;조영민;박덕신;김세영;박재형;조관현;유건종;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대 (Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment)

  • 노영만;이철민;김윤신;김석원;김치년;김현욱;조기홍;최호춘;김정만
    • 한국산업보건학회지
    • /
    • 제16권1호
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.