• 제목/요약/키워드: indoor air quality(IAQ)

검색결과 186건 처리시간 0.022초

지하철역사의 호선별로 미세먼지의 노출특성에 대한 평가 (Evaluation of Exposure Characteristics of Fine Dusts by Subway Lines)

  • 황성호;김종오
    • 한국환경보건학회지
    • /
    • 제43권1호
    • /
    • pp.71-76
    • /
    • 2017
  • Objectives: This study aimed to assess the environmental factors that affect particulate matters (PM10) and to compare with outdoor PM10 concentrations in an underground subway stations. Methods: The PM10 level was determined from May 2013 to September 2013 in the Seoul subway stations in four lines. PM mini-vol portable sampler sampler was used to collect PM10 for 6 hrs. Arithmetic means of PM10 concentrations with standard deviation (SD) were calculated. Paired t-test was used to compare the differences between indoor PM10 and outdoor PM10 concentrations with correlation analysis which was used to identify the association between indoor PM10 concentrations and environmental factors. Results: There were no different PM10 concentrations significantly between line 1, 2, 3 and 4 in an underground subway stations. Passenger number was positively associated with PM10 concentration while construction year was negatively associated with PM10 concentrations. Indoor PM10 concentrations were significantly higher than those in outdoor PM10 concentrations. PM10 concentrations were higher in the stations which were constructed before 1990s rather than the stations constructed after 1990s. Conclusion: PM10 levels in the underground subway stations varied greatly depending on the construction year. Therefore, it might need to be more careful management to the stations which constructed in before 1990s.

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인 (Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces)

  • 박희은;박정호;김형갑
    • 한국산업보건학회지
    • /
    • 제22권2호
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

기계식 환기시스템에 의한 선내 오염물질 확산 특성 예측 (A Prediction on Indoor Contaminant Diffusion Characteristics of a Training Ship by Mechanical Ventilation System)

  • 황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1124-1131
    • /
    • 2011
  • 본 연구는 기계식 환기장치에 의한 선박 선실 내의 환경오염물질 확산특성을 파악한 것으로, 연구성과는 다음과 같다. 오염발생 선실 내에서는 오염발생 35분 경과 후 오염물질이 대부분 제거되었고, 신선외기 도입율 변화에 따른 영향은 무시할 수 있었다. 오염원 선실에 인접한 선실의 오염물질 제거시간은 65분~100분 정도로 신선외기 도입율에 따라 차이가 발생했다. 상부 데크에 오염원 선실이 있는 경우가 하부 데크에 오염원 선실이 있는 경우에 비해, 오염농도는 10배 정도 높지만, 대표 공간 중 오염된 공간의 수는 오히려 1/2에 불과했다. 그러나 전체공간을 대상으로 한 평가에서는, 상부 데크에서 오염물질이 발생한 경우에는 Upper 데크 이상 상부 데크 내 공간의 50% 이상이 평가기준 0.001%, 0.01%, 0.1% 일 때 오염될 것으로 예측되었고, 하부 데크에서 오염물질이 발생하는 경우에는 하부 데크를 중심으로 오염공간이 많지만 오염판단기준 0.01%일 때에는 Shelter 데크 이상의 상부 데크에서도 오염선실이 나타났다. 한편, 신선외기 도입량 변화에 따른 오염농도 및 오염공간 비율을 분석한 결과 설계용량 대비 75% 이상의 외기가 도입될 때 선실 내 오염수준이 낮아지는 것으로 평가되었다.

주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구 (A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ)

  • 이정현;이승희;김태연
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

탑상형 공동주택의 주동형태와 배치각에 따른 주호의 자연환기 성능 (Improving the natural ventilation in multi-housing units of tower-type buildings according to their shapes and directions)

  • 유선용;김지영;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.897-902
    • /
    • 2006
  • Natural ventilation is an effective method for improving IAQ(Indoor Air Quality) and removing heats in buildings. In oder to use natural ventilation, many factors such as wind pressure around the buildings and possibility of air intake on different shapes need to be known. On this paper, the natural ventilation performance in multi-housing units of tower-type buildings was investigated. Tower-type multi-housing buildings are recently more and more constructed for they may change urban landscape and get more openness in multi-housing site. However, such housing buildings have problems with natural ventilation because of the various directions of the building units. The purpose of this paper is to find the proper building direction regarding to wind direction in order to optimize air intake in every units in the building.

  • PDF

식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석 (Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis)

  • 김태한;최부헌;최나현;장은숙
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.268-276
    • /
    • 2018
  • 본 연구는 일반인에게 안전한 실내공기질 개선수단으로 인식되는 공기정화식물의 효율적 적용을 위해 실내공조에 요구되는 총풍량 확보가 가능한 식생기반 바이오필터 시스템을 제안하고자 했다. 시스템의 정량적 성능평가는 강의실형태의 실험실 체적 $332.73m^3$ 내 16명의 재실자 조건에서 목업단위 시스템의 공조 성능, 실내공기질 및 쾌적지표 개선효과에 대한 시계열 분석으로 진행되었다. 우선, 시스템 구동을 통해 총 $1,411.22m^3/h$의 유출 총풍량을 확보하여, 4.24 ACH의 환기율을 제공할 수 있었다. 실내온도는 $1.6^{\circ}C$, 흑구온도는 $1.0^{\circ}C$ 감소가 확인되었으며, 상대습도는 24.4% 상승한 최대 82.0%까지 증가하였다. 상대습도 급증에 따른 쾌적도 감소현상은 송풍기 구동에 따라 발생되는 실내기류로 상쇄되는 것으로 판단된다. 또한, 시스템 가동에 따른 공기질 개선지표 중 $PM_{10}$은 39.5% 감소한 평균 $22.11{\mu}g/m^3$을 기록하였다. 반면, $CO_2$는 최대 1,329 ppm까지 지속적으로 농도가 상승했는데, 이는 광도조건이 광보상점을 만족하지 못해 적용 식물과 재실자에서 방출되는 $CO_2$가 처리되지 못한 것으로 해석된다. 실내쾌적지표의 경우 PMV는 평균 83.6 % 감소된 -0.082, PPD는 평균 47.0% 감소된 5.41%에 수렴하여 식생기반 바이오필터 구동에 의해 높은 쾌적범위의 실내공간조성이 가능한 것으로 판단되었다. 본 연구의 한계는 소수 참여인원과 단기간 실험으로 인하여 시스템의 성능 규명이 제한적인 부분이었으며, 보다 장기간의 실험을 통해 바이오필터에 도입된 식생의 생육상태에 따른 압력손실 변화, 미세먼지 저감에 대한 구체적인 메커니즘 규명 등의 후속연구가 진행되어야 할 것이다.

유아교육시설의 표면 및 공기 중 납 농도 평가 (Evaluation of Airborne and Surface Lead Concentrations in Preschool Classroom)

  • 윤충식;백도현
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This study was performed to investigate airborne lead concentration and surface lead contents in preschool facilities. Arithmetic mean of indoor lead concentration in urban area was $44.7\;ng/m^3$ (Geometric mean $32.1\;ng/m^3$) whereas outdoor concentration was $39.5\;ng/m^3$ (GM $22.8\;ng/m^3$). In rural area, airborne lead concentrations were $14.2\;ng/m^3\;(GM\;7.9 ng/m^3),\;12.6\;ng/m^3\;(GM\;5.6 ng/m^3)$, respectively. There is statistical significance of the lead concentrations among the locations of preschool facilities. About $37\%$ of qualitative lead check samples was positive and mainly was found in lead based paint. Though lead concentrations on the floor and window sill were well below the US EPA and HUD standard (floor $40\;{\mu}g/ft^2\;(4.3\;{\mu}g/100\;cm^2)$, window sill $250\;{\mu}g/ft^2\;(26.9\;{\mu}g/100\;cm^2)$, respectively), there were much samples which exceed the standard, i.e., $29\%$ of surface wall, $20\%$ of the desk and chair, $100\%$ of painted wood box of tested samples. In view of our study and hazard of lead to children, we recommended that the contents of lead in preschool facilities should be lowered as possible.

건축자재의 오염물질 방출 데이터베이스 개발; 휘발성유기화합물, 폼알데하이드 방출강도 및 화학조성 (Development of a building materials database; Volatile organic compounds, formaldehyde emission rates and chemical compositions)

  • 유영재;이철원;김만구
    • 분석과학
    • /
    • 제22권1호
    • /
    • pp.57-64
    • /
    • 2009
  • 이 연구에서는 건축자재로부터 방출되는 휘발성유기화학물과 폼알데하이드의 오염물질 방출강도를 포함하는 데이터베이스를 개발하였다. 건축자재 분류체계는 환경부와 한국공기청정협회에서 사용하는 분류체계와 연계하여 세분류하여 정립하였다. 개발된 데이터베이스는 각 건축자재로부터 방출되는 총휘발성유기화합물과 5가지 휘발성유기화합물, 그리고 폼알데하이드의 방출강도를 포함하며 화학적 성분 및 일반적인 정보를 함께 포함하기 때문에 평가 모델링을 통한 실내공기질 예측에 입력변수로 사용 가능하다. 건축자재 분류별 폼알데하이드와 총휘발성유기화합물의 방출강도를 box plot을 이용해 통계적 분석을 하였다. 또한 각 분류별 오염물질의 방출특성을 확인함으로써, 실내공기질을 악화시키는 주된 원인이 되는 건축자재를 확인 할 수 있었다.

통계분석을 이용한 아파트내 휘발성유기화합물의 환경인자 분석 (Analysis of VOCs Infiluencing Environment Factors Using Statistics in Apartment House)

  • 이세행;김난희;이경석;박강수;박승열;김도술;강영주;김은선;김동수
    • 한국대기환경학회지
    • /
    • 제28권4호
    • /
    • pp.435-445
    • /
    • 2012
  • The aim of this study is to understand the characteristics of volatile oranic compounds (VOCs) and provide information about the present Indoor Air Quality (IAQ) at residential apartments. All samples were collected in 60-min interval using the tenax absorption trap between May, 2011 and February, 2012. And the effects of environmental factors such as temperature, humidity and construction characteristics were analyzed in relation to the measured concentrations. The results of this study showed that the mean concentration of VOCs was lower than the Ministry of the Environment's standards for maintenance of indoor air quality. The correlation analysis showed that ethylbenzene and xylene (r=0.916, p<0.01), toluene and ehtylbenzene (r=0.810, p<0.01), toluene and xylene (r=0.803, p<0.01) and toluene and styrene (r=0.588, p<0.01) were significant. The result of regression analysis was found that the influenece factors associated with the concentration of VOCs were the age and location of the apartment, remodeling, the temperature and the season.

목질제품에서 방출되는 휘발성 유기화합물 특성 연구 (Characteristics of Volatile Organic Compounds Emitted from Wood-based Panels)

  • 박현주;손윤석;임보아;김조천;박상범
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.616-623
    • /
    • 2010
  • Recently, interests in indoor air quality (IAQ) have been increased; however, a number of researchers have mainly focused on anthropogenic volatile organic compounds (AVOC) emitted from building materials. Therefore, the properties of natural VOC (NVOC) and anthropogenic VOC (AVOC) emitted from wood-based panels was investigated in this work. VOCs emitted from these panels were sampled through Tenax TA/Cabotrap and analyzed by GC-MS and GC-FID. Comparisons were made concerning TVOC, NVOC, and composition ratios of NVOC. It was revealed that TVOC emission rates of midium density fiber (MDF) were the highest. Besides, it was found that emissions of NVOC from wood-based panels were much higher than those of anthropogenic AVOC except for plywood of Oceania timber. It was also observed that the composition ratio of NVOC emitted from plywood of Pinus radiata was the highest as 65% of TVOC. Major NVOC components were monoterpene compounds such as $\alpha$-pinene, $\beta$-pinene, d-limonene, camphene and $\alpha$-terpinene. It was concluded that the composition rates of VOCs emitted from building materials were clearly different according to the raw materials and manufacturing methods.