• Title/Summary/Keyword: indoor air pollution

Search Result 431, Processing Time 0.022 seconds

Radon adsorption properties of cement board using anthracite (안트라사이트를 혼입한 시멘트 보드의 라돈흡착 특성)

  • Kyoung, In-Soo;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.232-233
    • /
    • 2018
  • Among the recent environmental pollution, indoor air pollution has an adverse effect on the health of indoor residents. Radon, one of the causes of indoor air pollution, is released from concrete, gypsum board and asbestos slate among building materials. Radon is a primary carcinogen and is a colorless, tasteless, odorless inert gas that adheres to airborne dust and enters the body through breathing. At this time, there is a risk of developing cancer if the alpha rays from the lononggas entering the human body destroys the lung tissue and is continuously exposed to a high concentration of lonon gas. The World Health Organization (WHO) has emphasized the reduction of radon and its exposure to radon by classifying it as a first-level carcinogen, but many people have not recognized it yet, and the research is underdeveloped. Therefore, this study was carried out to investigate the properties of adsorbed coconut radon to prevent the inflow of radon gas, which is an air pollution source of indoor air, and to prevent inflow into the human body.

  • PDF

A study of Recognition of Indoor Air Quality of Indoor Environment at School (학교 실내 환경의 실내공기질 인식에 관한 연구)

  • Hong, Eun-Ju;Kim, Jung-Duck;Jeon, Young-Taek;Lee, Che-Won;Moon, Jeong-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.51-64
    • /
    • 2007
  • This research, selected for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003, in order to study of Recognition of Indoor Air Quality of Indoor Environment at School. we used Questionnaire for 193 health teachers, 41 teachers, and 1,359 students. The results of study are as follows. 1. To the question 'Currently Were you damage caused by classroom air?', showed that worry class teachers more than students with 43.9% of class teachers, 35.9% of health teachers and 23.5% of students. 2. To the question 'What would be an efficient way to manage classroom sanitation?', 50% of class teachers, 40.5% of health teachers and 47.4% of students wanted 'installation of air purifier.' 3. To the question 'How are you getting information about indoor air pollution?', showed that all of 3 groups get information through on TV. 4. According to survey, Health teachers who act as health supervisors appeared to have more prior knowledge air quality than class teachers and students. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. Therefore, these results suggested that a logical and systematic education program for students about the importance of indoor air quality should be carried out.

Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network (저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.397-400
    • /
    • 2007
  • Indoor air-conditioning system(IAS) using wireless sensor network serves to reduce the amount of pollution entering the room from outside and also the pollution that is generated indoor. Small-size and lower power wireless sensor node and sensor interface board was designed for indoor air-conditioning system in buildings of offices and industrial establishments. Many sensor nodes forms Ad-hoc network topology using simple forwarding routing to transmit polluting gas concentration data from different rooms to the indoor air-conditioning system. Sensor node analyzes pollution concentration in the each room and air-conditioning system performs to air-distribution and air-inhalation according to room's pollution by regulating the fan of indoor air-conditioning system. To reduce power consumption electrochemical gas sensor was used in the design. Thus the designed system can optimize state of indoor environment. Graphic user interface displays node sate, gas concentration and temperature of each room.

  • PDF

A study on the finishing materials for Reduction of Indoor pollution (실내 환경오염 감소를 위한 건축마감 재료에 관한 연구)

  • Kim, Ja-Kyung;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.303-313
    • /
    • 2007
  • Nowadays, according to many studies, indoor space's pollution level is two to ten times higher than outdoor space's. This result arouses our attention. The major causes of deterioration of indoor air quality are the lack of ventilation caused by draught-proofing and insulation construction, and harmful chemical substances emitted from building materials, office machine and furniture. Therefore, we are continuing research to find the method for healthful house and production of many forms of well-being goods. However, because of exaggerated advertisements and the lack of accurate information, consumers choose the products whose performance is not verified. Therefore, this study investigates the actual conditions of pollution by building materials and the extent of the health damage by this pollution, and suggests the method for minimizing indoor pollution in aspect of indoor environment control and the use of environment friendly materials. But the building materials presented in this study are limited to the environment friendly construction materials that are in circulation In domestic market because this research is primarily aimed to give domestic consumers the standard for selecting this materials.

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

A Study on the Indoor Air Pollution Level and Its Health Significance in Working and Living Spaces (일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구)

  • Shin, Dong-Chun;Lee, Hyo-Min;Kim, Jong-Man;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.73-84
    • /
    • 1990
  • The study was carried out to investigate the extent of indoor air pollution in living rooms of apartment houses(residential area) and offices(traffic area A : no smoking space, B : smoking space) in Seoul and to determine the health significance of indoor air pollution. Indoor and outdoor concentrations of major air pollutants were observed simultaneously from February 13 to 17, and July 24 to 28, 1988. The concentrations of carbon monoxide(CO), nitrogen oxides(NOx), sulfur dioxide($SO_2$), carbon dioxide($CO_2$) and total suspended particulate(TSP) in living room and offices were measured and the results were summarized as follows: 1. Both in summer and in winter, the indoor concentrations of CO, $CO_2$, and TSP in offices were higher than the outdoor concentrations, on the other hand, $SO_2$ was higher in the outdoors and NOx was lower than the outdoor concentration only in office A where smoking is not permitted. 2. The indoor and outdoor pollution of offices in winter was significantly higher than that in summer, and the concentrations of CO, NOx and $SO_2$ in indoor and outdoor air in living room in winter were also higher than those in summer. These results suggest that indoor levels of air pollutants are affected by smoking and winter heating systems.

  • PDF

The Evaluation and Investigation of Conscious Cognition Degree on a room-size air cleaner (실내용 공기청정기의 성능평가 및 인식도 조사)

  • 손종렬;김영환;우완기
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.115-120
    • /
    • 2002
  • This study was performed on a questionnaire survey of 500 people about their awareness for indoor air pollution, and measured efficiency of air cleaner which can remove the CO and air-borne particulate of ETS(Environmental Tobacco Smoke) in air clean chamber. The room-size cleaner for measuring indoor air contaminants has been applied to evaluation of two different air cleaner such as the mechanic air cleaner with hepafilter(HPA) and the electrostatic air cleaner with metal plate. The measuring experiment was carried out in a chamber by sampling the air. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 38% of them can feel indoor air pollutions degrees directly by their sense of smell, For the installation of indoor pollution control equipment, 34% of all respondents installed air cleaner because of the problem of economical charge and almost respondents was not satisfied the trust of ability purified indoor air pollutants. In the experimental results, it was found that more than 95% of CD and air-borne particulate of ETS were removed within 20 minutes. The reaction kinetics of removal pollutants was verified as the pseudo-first order, Finally, it appeared that the room-sire air cleaner can be applied to new technology for removing indoor air contaminants.

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.

Microbiologic Pollution of Indoor Air in Industrial Work-Places (산업체 작업환경의 실내 공기에서 미생물 오염도)

  • 강경희;장명웅
    • Journal of Life Science
    • /
    • v.9 no.3
    • /
    • pp.314-327
    • /
    • 1999
  • This study was investigated to isolate identify the total bacteria and fungi from the indoor air of work-place of the shoes, paint, stainless steel, and plastic industries. The number of bacterial colonies on the nutrient agar plates were calculated by the open petridish method for 30 minutes in indoor air of work-places at the autumn and winter. The isolated bacteria were identified by Gram stain and biochemical test using API Staph and API 20E kits. The isolated fungal colonies were identified by gross appearance of the giant colonies and microscopic examination of their spore and hyphal characteristics on the slide culture method. The minimum inhibitory concentration (MIC) of several antibiotics against isolated bacteria was determined by the microdilution method with Mueller-Hinton broth. The 70-400 colonies in autumn and 54-236 colonies in winter were isolated from the indoor air of work-places of several industry. The isolation rates of Gram positive cocci, Gram positive bacilli, Gram negative bacilli, and Gram negative cocci were 46.3%, 19.8%, 17.3%, and 16.1%, respectively. In Gram positive cocci, the most strains were identified as Aerococcus spp, Micrococcus spp, and Staphylococcus spp. In Gram positive and negative bacilli, and Gram negative cocci were identified as Bacillus spp, Pseudomonas spp, and Neisseria spp, respectively. The frequently isolated fungi were Aspergillus spp, Penicillium spp and Rhizopus spp, respectively. The frequently isolated Aerococcus spp, Micrococcus spp, and Staphylococus spp were highly resistance against ampicillin, erythromycin, methicillin, and tetracycline. These results arouse our attention to microbiologic pollution in the indoor air of work-places of industries.

  • PDF