• Title/Summary/Keyword: indoor air pollutants

Search Result 308, Processing Time 0.035 seconds

Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses (신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

Potential Exposure to RSP, $NO_2$ and VOCs for Taxi Professional Driver

  • Kim, Dae-Won;Lee, Jung-Eun;Son, Bu-Soon;Kim, Young-Hee;Yang, Won-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.299-302
    • /
    • 2005
  • Vehicle occupant exposure to air pollutants has been a subject of concern in recent years because of higher levels of air pollutants inside gasoline or diesel-using vehicle, comparing to the surrounding atmosphere. This study evaluated the potential exposure to respirable suspended particulate (RSP), nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs), comparing weekday (Monday and Thursday) and weekend (Saturday). Indoor mean concentrations of RSP inside vehicle were 51.2 $ug/m^3$ and 75.52 $ug/m^3$ in weekday and weekend, respectively. Measured indoor NO$_2$ concentrations were 14,8 ppb and 20.8 ppb, respectively. Benzene and toluene mean concentrations inside vehicle were 5.4${\pm}$2.4 ppb and 23.8${\pm}$33.8 ppb, respectively.

  • PDF

Thermal Conductivity Properties of Magnesium Oxide Matrix using Vermiculite and Anthracite (버미큘라이트 및 안트라사이트를 활용한 산화마그네슘 경화체의 열전도율 특성)

  • Lim, Hyun-Ung;Gwon, Oh-Han;Pyeon, Su-Jung;Lim, Gguk-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.80-81
    • /
    • 2017
  • The study conducted a thermal conductivity test of magnesium oxide to manufacture boards using absorbent to produce board of radon gas molecules that are absorbed into the indoor air pollutants, which are currently in question, among other indoor air pollutants. Using material are the vermiculite and anthracite, in case of the vermiculite, which results in large porosity due to the expansion, in case of the anthracite, which characteristic generates pore on the matrix. As a result of the experiment, the lowest value was given to 0.6161 kcal/mh℃ which adding vermiculite 10% and anthracite 40%. However, adding vermiculite 40% and anthracite 10%, slightly higher 0.7229 kcal/mh℃, it is deemed the anthracite has more porosity than the vermiculite and, it judged that pore occurrence during the mixing process, appeared that the heat conductivity go down.

  • PDF

Efficiency Evaluation of Operating Railroad with Subway Cabin Air Purifier (도시철도 객실 공기정화장치(SCAP)의 운행차량 효율평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;NamGoong, Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1303-1308
    • /
    • 2011
  • In the modern society various types of transportation mode are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day. Because of interests on the indoor air quality (IAQ) of underground public facilities, concerns on IAQ of subway system by many people are increasing. There are several approach to improve IAQ of subway station, such as installing platform screen door (PSD), frequent tunnel washing-out, and etc, however there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin since the problem of maintenance cost. Therefore, the ultimate object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. The subway cabin air purifier (SCAP) was developed for removing particulate matters and gases pollutants inside a cabin. The whole system was designed and the roll-filter device was manufactured based on numerical prediction results. It is expected that SCAP could reduce indoor air pollutants in the subway cabin practically and it can be applied to other part of transportation vehicles.

  • PDF

Properties of Fine Dust Adsorption Matrix According to the Powdered Activated Carbon Mixing Method based on Blast Furnace Slag (고로슬래그 기반 분말활성탄 혼입방법에 따른 미세먼지 흡착형 경화체의 특성)

  • Kim, Yeon-Ho;Jo, Eun-Seok;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.68-69
    • /
    • 2020
  • Recently, the problem of air pollution is drawing attention as a social problem worldwide. Particularly, fine dust is the biggest issue among air pollutants, and it is analyzed that fine dust is generated from air pollutants such as burning fossil fuels such as petroleum or coal, or exhaust gases from automobiles. In addition, yellow dust originating from China adjacent to Korea flows into the Korean Peninsula in a western wind, causing the concentration of fine dust to deteriorate. Fine dust is a harmful substance to the human body such as asthma or respiratory disease, and awareness of the risk is also increasing to a degree designated as a primary carcinogen. In this study, as a method for improving the indoor air quality, the Properties of the matrix according to the mixing ratio of powdered activated carbon based on blast furnace slag are reviewed. The flexural strength and compressive strength were measured, and a fine dust concentration measurement experiment will be conducted later.

  • PDF

A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House (都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究)

  • Park, Mi-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

Improvement of Indoor Air Quality by Coating of Indoor Materials of $TiO_2$ Photocatalyst Sol (이산화티탄 광촉매 졸(sol)의 실내환경 코팅에 의한 실내공기질 개선)

  • 양원호;김대원;정문호;양진섭;박기선
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.92-97
    • /
    • 2004
  • Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.